background image

 

Thank you very much for choosing our product. For safety purpose, please read this manual carefully before your 
operation. This manual included installation and using information. Please install and operate it according to this 
manual.

 

SAFETY WARNINGS 

   

 

 

WARNING : 

Please keep this User Guide for future consultation. If you sell the unit to 

another user, be sure that they also receive this instruction booklet.

 

Caution

 

 

All fixtures are intact from the manufacturer, please operate follow up the user manual, artificial fault are not 

under guarantee repair. 

 

Unpack and check carefully there is no transportation damage before using the unit. 

 

Do install and operate by operator. 

 

Use safety chain when fixes the unit. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.  

 

Before  operating,  ensure  that the  voltage  and  frequency  of  power  supply  match  the  power  requirements  of 

the unit. 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

Maximum ambient temperature: 40

. Don’t operate it where the temperature is higher than this. 

 

Don’t connect the device to any dimmer pack. 

 

First run, there will be smoke or smells, and all disappearing a few minutes later. 

 

Make sure there are no flammable materials close to the unit while operating, as it is fire hazard. 

 

Look over power wires carefully, replace immediately if there is any damage. 

 

Unit surface temperature may reach up to 60

. Don’t touch the housing bare-hand during its operation. 

 

Never run on for a long time lest shortening lifespan. 

 

Avoid  any  inflammable  liquids  or  metal  objects  entering  the  unit.  Once  it  happen,  cut  off  the  mains  power 

immediately. 

 

The fixtures must be cleaned regularly if they are in a dirty and dusty environment 

 

Do not allow children to operate the fixture. 

 

Do not touch any wire during operation as there might be a hazard of electric shock. 

 

Avoid power wires together arounding other cables. 

 

Replace fuse only with the same type. 

 

In the event of serious operating problem, stop using the unit immediately. 

 

Never turn on and off the unit time after time. 

 

Do  not  open  the unit as  there  are  no  user  serviceable  parts  inside.  Never  try  to  repair  the  unit  by  yourself. 

Repairs  carried  out  by  unskilled  people  can  lead  to  damage  or  malfunction.  Please  contact  the  nearest 

authorized technical assistance center.  

 

Disconnect the mains power if the fixture is not used for a long time. 

 

Do use original packing materials once transport it again. 

 

Do not look directly at the LED light beam while the fixture is on. 

 

 

PRODUCT 

 

Product introduction 

This product is designed for indoor use. Suitable applications include wash, effect lighting for architectural, stage 
or nightclub applications. This product can also be installed for use in signage and advertising using the dynamic 
functions available with DMX512 control. Direct input of DMX512 signal allows the units to be controlled from any 
DMX512 controller. This product can be operated as a single unit or in multiple units for large applications.

 

Summary of Contents for BP DOT

Page 1: ...BP DOT Manuel d utilisation Nous vous recommandons de lire attentivement le manuel avant toute utilisation...

Page 2: ...au bout de quelques minutes Par s curit assurez vous qu aucun produit inflammable ne se trouve c t de l appareil lors de l utilisation Ne pas toucher les fils pendant que l appareil fonctionne afin d...

Page 3: ...peut tre mont en suspension gr ce l om ga de fixation pouvant tre mont sur une structure ou un pont de mani re s curis e une lingue suppl mentaire reste obligatoire Montage vertical Le produit peut t...

Page 4: ...m tre Navigue vers le menu pr c dent ou d cr mente la valeur du param tre Valide la selection ou le parametre Permet de descendre dans le menu courant ou de sauvegader la valeur du parameter avant de...

Page 5: ...000 255 Variateur VERT 2 4 Light Blue 000 255 Variateur BLEU 2 5 Light White 000 255 Variateur BLANC 2 6 Scan Pan 000 255 2 7 Scan Tilt 000 255 2 8 Scan Pan Fine 000 255 2 9 Scan Tilt Fine 000 255 2 1...

Page 6: ...Change Color Twinkling Fade 5 Test menu Menu Menu Options Test menu 5 1 Test All Test LED and Electric machinery Test OFF Test ON 5 2 Test LED Test OFF Test ON 5 3 Test P T Test Electric machinery Te...

Page 7: ...ux DMX BP DOT contient 4 modes de canaux DMX la mode par d faut est le Mode 17 canaux Mode 17 Canaux par d faut Canaux Valeur Fonction 1 000 255 Pan 2 000 255 Pan r glage fin 3 000 255 Tilt 4 000 255...

Page 8: ...couleurs fonction roue couleur 15 000 255 Couleur fixe 16 000 255 Variateur gn ral couleurs fixes 17 Canal de fonctions 0 9 Mode normal 80 87 Remise zero de l appareil 88 90 Variateur RAPIDE 91 93 Va...

Page 9: ...LENT RAPIDE 96 127 LED allum e 128 159 Effet puls en s quences 160 191 LED allum e 192 223 Strobe al atoire de LENT RAPIDE 224 255 LED allum e 11 000 255 Variateur G n ral 12 000 255 Variation de cou...

Page 10: ...RT 5 000 255 Variateur BLEU 6 000 255 Variateur BLANC 7 000 255 Variation de couleurs fonction roue couleur 8 Rotation continue sur le PAN 0 127 Sans effets 128 189 Rotation PAN Clockwise de RAPIDE LE...

Page 11: ...e activ 90 109 BURST 110 129 Strobe al atoire 130 149 Burst al atoire activ 150 169 Onde sinuso dale 170 189 Pulsations en ouverture 190 209 Pulsations en fermeture 210 229 Strobe al atoire 230 249 Pu...

Page 12: ...manuel Mettez l appareil sous tension il doit afficher A001 Utilisez UP DOWN jusqu manual dimmer Utilisez UP DOWN jusqu aux menus suivants Red Variateur ROUGE Green Variateur VERT Blue Variateur BLEU...

Page 13: ...Fade Cliquez ENTER pour valider ou SET pour ressortir ST02 Menu du PAS num ro 2 Cliquez ENTER puis UP DOWN pour s lectionner le programme allouer au PAS courant parmis Change Color Twinkling et Fade...

Page 14: ...par le canal 7 utilisera les canaux DMX 7 8 et 9 si on lui programme l adresse de d part 7 Si l on programme la m me adresse pour plusieurs appareils ils recevront les m mes donn es Param trer le cana...

Page 15: ...BP DOT USER MANUAL Please read the instructions carefully which includes important information about the installation operation and maintenance...

Page 16: ...face temperature may reach up to 60 Don t touch the housing bare hand during its operation Never run on for a long time lest shortening lifespan Avoid any inflammable liquids or metal objects entering...

Page 17: ...ocated on the side of the fixture CARACTERISTIQUES TECHNIQUES DMX Channels Modes 17 15A 15B 12 Running Modes Master Slave DMX Manuel musical LED 1 x 60W Colours RGBW Display Blue LCD Stroboscope 1 25...

Page 18: ...2 No DMX Signal 1 2 1 Close Shutter 1 2 2 Hold 1 2 4 Music Control 1 3 DMX Channels STAG Mode 17 Channels 15A Channels 15B Channels 12 Channels AXXX AXXX 1 DMX Menu 2 Manual Dimmer 3 Demo Menu 4 Macro...

Page 19: ...rate Cal Red 99 0 Cal Green 99 0 Cal Blue 99 0 Cal Pan 128 127 Cal Tilt 128 127 3 Demo menu Menu Menu Options Demo menu 3 01 Red 000 255 3 02 Green 000 255 3 03 Blue 000 255 3 04 Yellow 000 255 3 05 C...

Page 20: ...set Machine Reset ON Reset OFF 6 02 Load parameter Load ON Load OFF 6 03 Auto Sound Set the automatic sound mode Auto Mode Sound mode 6 04 MIC sense MIC sensitivity 00 99 6 05 TC switch Temperature sw...

Page 21: ...Clockwise From fast to slow 190 193 Stop 194 255 Anticlockwise From slow to fast 7 Tilt continuous rotation 0 127 No function 128 189 Clockwise From fast to slow 190 193 No function 194 255 Anticlockw...

Page 22: ...Back light off 250 255 Back light on 15A channels mode Channel Value Function 1 000 255 Pan 2 000 255 Tilt 3 000 255 Scanning speed 4 Pan continuous rotation 0 127 No function 128 189 Clockwise From...

Page 23: ...rogram 2 140 159 Internal program 3 160 179 Internal program 4 180 199 Internal program 5 200 219 Internal program 6 220 239 Internal program 7 245 250 Back light off 250 255 Back light on 15B channel...

Page 24: ...lt 13 000 255 Tilt Fine 14 000 255 Scanning speed 15 Function channel 0 9 Normal 80 87 Reset fixture 88 90 Fast dimmer 91 93 Smooth dimmer 94 96 no function 97 99 no function 100 119 Internal program...

Page 25: ...194 255 Anticlockwise From slow to fast 8 000 255 Pan 9 Tilt continuous rotation 0 127 No function 128 189 Clockwise From fast to slow 190 193 Stop 194 255 Anticlockwise From slow to fast 10 000 255 T...

Page 26: ...m quantity Program Step program steps number Macro call the built in programs circularly each step is one of built in program This menu is used for setting the steps number If the number is set to 3 s...

Page 27: ...ing can controlled by controller When the display shows A001 or the other actual stored addresses the lighting is in DMX mode Selecting channels mode When the lighting is in DMX mode and showing the s...

Page 28: ...ixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts...

Reviews: