• Fault log
This function enables display of any faults occurring during the last 8 manoeu-
vres, such as an interruption to a manoeuvre caused by activation of a photo-
cell or a sensitive edge. To check the list of faults, proceed as described in
Table 12
.
TABLE 10
01.
Press and hold down the “
Set
” key for approx. 3 seconds;
02.
Release the key when LED
L1
starts flashing.
03.
Press keys “
▲
” or “
▼
” to move from the flashing led to led L7;
04.
Press and hold the “
Set
” key through to completion of point 07;
05.
Wait approx. 3 seconds, until the LED representing the current level of the “Maintenance Notification” illuminates;
06.
Press and immediately release the “
▲
” or “
▼
” keys;
07.
The led corresponding to the selected level shows a series of flashes. to indicate that the manoeuvre counter has
been reset. The number of flashes indicates the percentage of the set limit of manoeuvres performed (as multiple of 10%).
Example: when the maintenance notification is set on L7 (40000), 10% corresponds to 1000 manoeuvres;
if the indicator led flashes 4 times, this means that 40% of the manoeuvres have been completed (between 4000 and
4999 manoeuvres).
If at least 10% of the manoeuvres has not yet been reached, no flashes are emitted;
08.
Release the “
Set
” key.
SET
SET
SET
SET
L1
or
and
L7
3 s
3 s
x 1 = 10-19%
x 2 = 20-29%
x 3 = 30-39%
x 4 = 40-49%
x 5 = 50-59%
x 6 = 60-69%
x 7 = 70-79%
x 8 = 80-89%
x 9 = 90-99%
x 10 = > 100%
TABLE 11
01.
Press and hold down the “
Set
” key for approx. 3 seconds;
02.
Release the key when LED
L1
starts flashing.
03.
Press keys “
▲
” or “
▼
” to move from the flashing LED to L7 LED (“input LED” for the “Maintenance Notification” parameter);
04.
Press and hold the “
Set
” key through to completion of point 07;
05.
Wait approx. 3 seconds, until the LED representing the current level of the “Maintenance Notification” illuminates;
06.
Press and hold keys “
▲
” and “
▼
” for at least 5 seconds, then release. During this phase the led corresponding to the
selected level shows a series of quick flashes to indicate that the manoeuvre counter has been reset;
07.
Release the “
Set
” key.
SET
SET
SET
SET
L1
L7
or
and
3 s
TABLE 12
01.
Press and hold down the “
Set
” key for approx. 3 seconds;
02.
Release the key when LED
L1
starts flashing.
03.
Press keys “
▲
” or “
▼
” to move from the flashing LED to L8 LED (“input LED” for the “Fault log” parameter);
04.
Press and hold the “
Set
” key through to completion of point 06;
05.
Wait approx. 3 seconds until the LEDs representing the levels corresponding to the manoeuvres with faults illuminate.
Led L1 indicates the result of the most recent manoeuvre, and led L8 indicates the result of the eighth manoeuvre; if a led
is lit, this means that one or more faults have occurred during the manoeuvre; if off this means that the manoeuvre has
been completed correctly.
06.
Press keys “
▲
” and “
▼
” to select the required manoeuvre: the corresponding LED performs a number of flashes equal to
those normally performed by the flashing light after a fault occures (see
Table 15
);
07.
Release the “
Set
” key.
SET
SET
SET
SET
L1
L8
or
and
3 s
3 s
Summary of Contents for S-BAR
Page 78: ...I 2 1 A B C B 179 5 mm 330 mm 1146 mm 826 mm 4000 mm 3 b a d e f g h c ...
Page 79: ...II 5 A B C 1 2 4 ...
Page 80: ...III 9 10 90 6 A C B 7 8 B A ...
Page 81: ...IV 14 15 A B A B 11 A B 12 13 A B ...
Page 82: ...V 16 A B 17 18 ...
Page 83: ...VI 20 180 21 C C A B 1cm 1cm 19 A C B ...
Page 84: ...VII 22 23 26 L N 24 1 2 25 ...
Page 86: ...IX 30 A A B STOP 31 A B ...
Page 87: ...X 32 A B C D STOP 33 A B 34 ...
Page 88: ...XI 35 36 L8 37 A B 2 1 L7 L8 L8 A B C Op L5 L6 L7 L8 Stop Set Close F u s e 1 A T 38 ...
Page 89: ...XII 300 200 700 500 39 300 200 700 500 150 40 41 ...
Page 90: ...a c d e b XIII F2 F1 42 43 ...
Page 91: ...XIV 44 O pe n L1 L2 L3 L4 L5 L6 L7 L8 St op Se t Cl os e Fuse 1AT 45 f g ...
Page 93: ...IST SBARR01 4865_20 10 2011 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com ...