Led 8
Description
Off
During normal operation it indicates that Pole closing is set to the left.
On
During normal operation it indicates that Pole closing is set to the right
Flashes
Programming of functions in progress.
EN
14
– English
TABLE 16
Signal
Cause
Solution
8.4.2 - Flashing light signals
If a flashing light is connected to the FLASH output on the control unit (or the
edge light if the LED flashing light XBA7 is connected, optional accessory), this
emits flashes at intervals of 1 second during execution of a manoeuvre. If faults
occur, the flashing light will emit shorter flashes; these are repeated twice, sep-
arated by a 1 second pause. The same signals are also emitted by the courtesy
light and the “Bluebus” led.
Table 16
shows the cause and solution for each
type of signal.
1 flash
second pause
1 flash
Bluebus system error
At the start of the manoeuvre, the devices connected to Bluebus
do not correspond to those recognized during the self-learning
phase. One or more devices may be faulty; check and, if necessa-
ry, replace them. In case of modifications repeat the device self-
learning process (see paragraph 4.5).
2 flashes
second pause
2 flashes
Photocell activated
At the start of the manoeuvre, one or more photocells do not ena-
ble it; check to see if there are any obstacles.
3 flashes
second pause
3 flashes
Activation of Motor Force limiter
During the movement, the pole has experienced excessive fric-
tion; identify the cause.
6 flashes
second pause
6 flashes
Maximum limit of manoeuvres per hour exceeded
Wait a few minutes until the manoeuvre limiting device falls to
below the maximum limit.
7 flashes
second pause
7 flashes
Error in internal electric circuits
Disconnect all power circuits for a few seconds and then retry a
command; if the condition persists this may indicate a serious fault
with the board or motor wiring. Check and make replacements as
necessary.
8 flashes
second pause
8 flashes
–
Reserved for Nice Technical Assistance
9 flashes
second pause
9 flashes
Block automation
Send the command “Release automation” or control the manoeu-
vre with “High Priority Step Step”.
4 flashes
second pause
4 flashes
STOP input activation
At the start of the manoeuvre or during the movement, the STOP
input was activated; identify the cause.
5 flashes
second pause
5 flashes
Error on internal parameters in control unit
Wait at least 30 seconds, then try giving a command. If the condi-
tion persists, there may be a serious malfunction and the electro-
nic board must be replaced.
Summary of Contents for S-BAR
Page 78: ...I 2 1 A B C B 179 5 mm 330 mm 1146 mm 826 mm 4000 mm 3 b a d e f g h c ...
Page 79: ...II 5 A B C 1 2 4 ...
Page 80: ...III 9 10 90 6 A C B 7 8 B A ...
Page 81: ...IV 14 15 A B A B 11 A B 12 13 A B ...
Page 82: ...V 16 A B 17 18 ...
Page 83: ...VI 20 180 21 C C A B 1cm 1cm 19 A C B ...
Page 84: ...VII 22 23 26 L N 24 1 2 25 ...
Page 86: ...IX 30 A A B STOP 31 A B ...
Page 87: ...X 32 A B C D STOP 33 A B 34 ...
Page 88: ...XI 35 36 L8 37 A B 2 1 L7 L8 L8 A B C Op L5 L6 L7 L8 Stop Set Close F u s e 1 A T 38 ...
Page 89: ...XII 300 200 700 500 39 300 200 700 500 150 40 41 ...
Page 90: ...a c d e b XIII F2 F1 42 43 ...
Page 91: ...XIV 44 O pe n L1 L2 L3 L4 L5 L6 L7 L8 St op Se t Cl os e Fuse 1AT 45 f g ...
Page 93: ...IST SBARR01 4865_20 10 2011 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com ...