Use in acid, saline or potentially explosive
atmosphere
Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In
any case, the manufacturer guarantees their functionality and fitness for the intended purposes.
All the technical characteristics refer to an ambient temperature of 20°C (±5°C)
8) Technical characteristics
Type
Model
Technical characteristics: ROBUS
Electromechanical gearmotor for the automatic movement of sliding gates for residential
use, complete with electronic control unit
RB400
Pinion
Z: 15; Module: 4; Pitch: 12.6 mm; Pitch diameter: 60mm
Peak thrust
[corresponding to the ability to develope a
force capable of moving the leaf]
18Nm
[400N]
Nominal torque
[corresponding to the ability to develope a force
capable of maintaining the movement of the leaf]
7Nm
[200N]
Nominal torque speed
0,15m/s
Idling speed (the control unit allows 6 speeds
to be programmed, approx. equal to: 100, 85,
70, 55, 45, 30%) 70, 55, 45, 30%)
0,31m/s
Maximum frequency of operating cycles
(nominal torque)
100 cycles / day (the control unit allows up to
the maximum described in tables 2 and 3)
Maximum continuous operating time (nomi-
nal torque)
7 minutes
(the control unit limits the continuous operation
up to the maximum described in tables 2 and 3)
Operating limits
In general, ROBUS is suitable for the automation of gates featuring weights or lengths as
shown in Tables 2, 3 and 4
Durability
Estimated between 20,000 and 250,000 cycles, following the conditions indicated in
table 4
Thrust maximum absorbed power [equiva-
lent to amperes]
515W [2,5A] [4,8A versione /V1]
Insulation class
1 (a safety grounding system is required)
Emergency power supply
With PS124 optional accessory
Flashing light output
For 2 LUCYB flashing lights (12V, 21 W lamp)
BLUEBUS Output
One output with a maximum load of 15 BlueBus units
Open Gate Indicator Output
for one 24V maximum 4W bulb (the output voltage may vary between –30 and +50%
and can also control small relays)
STOP input
For normally open contacts, for 8,2K
Ω
; constant resistance, or normally closed contacts; with
self-recognition (any variation from the memorized status causes the “STOP” command)
Step-by-step Input
For normally open contacts (the closing of the contact causes the “STEP-BY-STEP” command)
OPEN input
CLOSE input
For normally open contacts (the closing of the contact causes the “OPEN” command)
For normally open contacts (the closing of the contact causes the “CLOSE” command)
Radio connector
“SM” connector for SMXI and SMXIS receivers
Radio AERIAL Input
52
Ω
for RG58 or similar type of cable
ROBUS 600 – 1000 power supply
ROBUS 600 – 1000/V1 power supply
230Vac (+10% -15%) 50/60Hz.
120Vac (+10% -15%) 50/60Hz.
Programmable functions
8 ON-OFF functions and 8 adjustable functions (see tables 7 and 9)
Operating temperature
-20°C ÷ 50°C
No
Protection class
IP 44
Self-Recognition functions
Self-recognition of the type of “STOP” device (Normally Open, Normally Closed contact
or 8,2K
Ω
) Self-recognition of the gate length and calculation of the deceleration points
and the partial opening point.
24