background image

6.3 - Menu

Menu allows to perform Z-Wave network actions. In order to use the menu:
1.  Press and hold the service button to enter the menu, device blinks to signal adding status (see 7.2: Visual indications).
2.  Release the service button when device signals desired position with colour:

 

»

GREEN

 - reset energy consumption memory,

 

»

YELLOW

 - reset to factory defaults.

3. 

Quickly click the service button to select, 2 blinks of the same colour will confirm the selection.

6.4 Resetting to factory defaults

Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user 

configuration will be deleted. Resetting to factory defaults does not reset energy consumption memory.

1.  Press and hold the service button to enter the menu.
2.  Release service button when the device glows yellow.
3. 

Quickly click the service button to confirm.

4.  After few seconds the device will be restarted, which is signalled with the red colour.

Note. 

Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the 

primary controller is missing or inoperable. Certain device removal can be achieved by the procedure of removing described.

7

ACTIVATING SCENES

The device can activate scenes in the Z-Wave controller by sending scene ID and attribute of a specific action using Central Scene Command 

Class.
In order for this functionality to work, connect momentary or toggle switch to the IN1-IN4 inputs and set parameters 20-23 to 2, 3 or 4 (de-

pending on type of switch). 

Table A1 - Scene IDs for inputs

Input

Scene ID

IN1

1

IN2

2

IN3

3

IN4

4

Table A2 - Attributes for actions

Action

Attribute

Switch clicked once 

Key Pressed 1 time

Switch clicked twice 

Key Pressed 2 times

Switch clicked thrice

Key Pressed 3 times

Switch held*

Key Held Down

Switch released*

Key Released

* Not available for toggle switches.

8

ASSOCIATIONS

Association (linking devices) 

– direct control of other devices within the Z-Wave system network.

Associations allow:
•  reporting the device status to the Z-Wave controller (using Lifeline group),
•  creating simple automations by controlling other devices without participation of the main controller (using groups assigned to actions on 

the device).

Note. 

Commands send to 2nd–10th association groups reflect inputs operation according to device configuration, e.g. turning the first chan

-

nel on using input will send frame responsible for the same action. 

Summary of Contents for RGBW-Control

Page 1: ...EN Instructions and warnings for installation and use Universal remote control for RGB RGBW and other LEDs RGBW Control Nice...

Page 2: ...few shorter strips in parallel connection instead of one long strip connected serially The device is designed for installation in a wall switch box of depth not less than 60mm The switch box and elec...

Page 3: ...nput red LED color recommended OUT2 output connector controlled by IN2 input green LED color recommended OUT3 output connector controlled by IN3 input blue LED color recommended OUT4 output connector...

Page 4: ...manual 3 Quickly three times click the service button 4 If you are adding in Security S2 Authenticated input the underlined part of the DSK label on the box 5 LED will start blinking yellow wait for...

Page 5: ...ds in HSB mode HSB mode is enabled by setting parameter 150 to 1 Inputs correspond to different components in HSB colour space IN1 Hue IN2 Satu ration IN3 Brightness and IN4 input controls OUT4 output...

Page 6: ...is missing or inoperable Certain device removal can be achieved by the procedure of removing described 7 ACTIVATING SCENES The device can activate scenes in the Z Wave controller by sending scene ID...

Page 7: ...ence only 1 node can be assigned Table A3 Assocation groups mapping Root Endpoint Association group in endpoint Association Group 1 Endpoint 1 9 Association Group 1 Association Group 2 Endpoint 1 Asso...

Page 8: ...el 2 Momentary switch Central Scene 3 Toggle switch switch state on every input change Central Scene 4 Toggle switch contact closed ON contact opened OFF Central Scene Default setting 2 momentary swit...

Page 9: ...ting 0x05 0xFF 0x00 0x00 Water Alarm any notification no action Parameter size 4 bytes Parameter 32 Alarm configuration 3rd slot Description This parameter determines to which alarm frames and how the...

Page 10: ...ings 1 Key pressed 1 time 2 Key pressed 2 times 4 Key pressed 3 times 8 Key hold down and key released Default setting 15 Parameter size 1 byte Parameter 41 Input 2 sent scenes Description This parame...

Page 11: ...o the main controller Energy reports are sent no often than every 30 seconds Available settings 0 reports are disabled 1 500 0 01 5 kWh change in energy Default setting 10 0 1 kWh Parameter size 2 byt...

Page 12: ...eserved for separate channel from least significant IN1 to most significant IN4 Applicable for Basic Set and Switch Multilevel Set commands Available settings For every byte 0 99 255 Default setting 0...

Page 13: ...ASIC 0x20 V1 YES Multichannel Command Class MULTICHANNEL CC ROOT Endpoint 1 Generic Device Class GENERIC_TYPE_SWITCH_MULTILEVEL Specific Device Class SPECIFIC_TYPE_COLOR_TUNABLE_MULTILEVEL Command Cla...

Page 14: ...S_SECURITY_2 0x9F COMMAND_CLASS_SENSOR_MULTILEVEL 0x31 COMMAND_CLASS_APPLICATION_STATUS 0x22 Description EP6 reports the Voltage measured on Input 1 EP7 reports the Voltage measured on Input 2 EP8 rep...

Page 15: ...CC Endpoint 6 7 8 and 9 Sensor Type Scale Precision Size Description VOLTAGE V 1 2B Analog input 1 4 Lifeline reports ROOT COMMAND_CLASS_DEVICE_RESET_LOCALLY 0x5A DEVICE_RESET_LOCALLY_NOTIFICATION 0x0...

Page 16: ...ution degree 2 Software class Class A Maximum phase to ground voltage of the supply source Supplied by external SELV source up to 24V DC Protection against electric shock class Class III control Class...

Page 17: ...ances which if disposed of into the environment may cause serious damage to the environment or physical health As indicated by the symbol alongside disposal of this product in domestic waste is strict...

Page 18: ...www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com IS0845A00EN_17 03 2022...