TITAN 912L Linear Actuator
Installation Reference Manual
22
22
1. Open mechanical release, remove two Torx 25 screws, and lift off cover (IMAGE 11-1).
2. Locate terminal strip per IMAGE 11-2.
3. Unscrew old wires from terminal strip, loosen strain relief, and pull out cable per IMAGE 11-3.
4. Insert new cable into strain relief per IMAGE 11-3 and strip each wire back 1/8” and twist.
5. Screw stripped colored cable wires into actuator terminal strip as shown in IMAGE 11-4.
6.
Tighten strain relief, afix cover, close mechanical release, and lock.
11
ACTUATOR CABLE REPLACEMENT WIRING
IMAGE 11-1:
REMOVE COVER
IMAGE 11-3:
CABLE INSERTION
IMAGE 11-2:
LOCATE TERMINAL STRIP
IMAGE 11-4:
CABLE/TERMINAL STRIP WIRING
MECHANICAL
RELEASE (OPEN)
CABLE
STRAIN RELIEF
LIFT OFF COVER
TORX 25 TOOL
TERMINAL STRIP
LOCATION
WHITE
GREEN
ORANGE
YELLOW
BLUE
BLACK
RED
EXTEND LIMIT
COMMON
RETRACT LIMIT
ENCODER
ENCODER
MOTOR -
MOTOR +
SECTION 7: ACTUATOR CABLE REPLACEMENT WIRING
www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]