Quick start instructions

(For those who don't have time!)

Sliding Gate Operators

GDS 450, 630 “LI” Range

Made in Australia from Australian & quality imported components

Place operator in correct position (Pinion wheel to be parallel to

the gate and stepped out to allow for width of rack once it is

mounted onto the gate frame). Mark out fixings and fix operator

to the concrete pad.

Fix rack to the gate frame keeping 1mm-2mm clearance between

the rack teeth and Pinion wheel.

Once the rack is fixed move the gate and sight the rack

moving over the pinion wheel, check that most of the pinion

wheel meshes with the rack. Make sure rack runs freely over

the pinion wheel, any tights spots should be corrected by

adjusting the rack height. Check the operator is firmly bolted

down to the concrete pad.

Ensure stops are installed on the gate for the fully closed and fully

open positions.

Connect required P.E Beams. Adjust Limits to actuate prior to

gate end positions. Connect power supply. Turn on Power.

Observe that the M1 op and cl limit indicator led`s turn when

the corresponding limit switch is activated. If they are the

wrong way around, swap the op and cl limit wires around.

Summary of Contents for GDS 450LI

Page 1: ...nd Maintenance Manual Sliding Gate Operators Inbuilt Models GDS 450LI 630LI Range Made in Australia from Australian quality imported components DELTA VSD 10 Bennet Ave Melrose Park SA 5039 8374 3466 J...

Page 2: ...is fixed move the gate and sight the rack moving over the pinion wheel check that most of the pinion wheel meshes with the rack Make sure rack runs freely over the pinion wheel any tights spots should...

Page 3: ...if not reverse two of the motor wires at the inverter terminals Inverter settings can be adjusted via the keypad i e Opening speed closing speed and ramp times Automation settings operating modes are...

Page 4: ...llation 6 10 Electrical Cabling Mechanical Installation Electrical Connections Plan view layout conduit positions CB6 Control Board layout CB 6 Control inputs mode settings 4 Delta Variable Speed Driv...

Page 5: ...necessary signs to indicate any danger areas and automatic operation of the gate or door The operators are not designed to be used in any hazardous areas or areas subject to flooding etc All electric...

Page 6: ...position once finished undo wing nut drop enclosure back down then re tighten wing nut Mechanical Installation Ensure gate rolls easily and has been installed in a manner where there is no excessive...

Page 7: ...7 PLAN VIEW LAYOUT CONDUIT POSITION...

Page 8: ...ceiver 7 Motor 2 Limit Switch Inputs 8 Terminals for Isolated 24vAC Supply 21 Firmware Version Label for Limit Switch and Control Inputs 22 Light Control Relay Interface Connector 9 Pedestrian Access...

Page 9: ...exceed 30V A C D C 5Amps If an electromagnetic lock is used change one wire on the control board lock output to the normally closed output Use the light relay module if fitted to switch the applied v...

Page 10: ...a pre set pedestrian access time of 5 seconds which is intended to open the motor connected to M1 output only part way If these default times do not suit your needs simply use the procedure below to a...

Page 11: ...close command input linked to MI3 for speed setting Terminal MI3 Closing Speed Multi Step speed command input Terminal DCM command output terminal used for common PARAMETER NUMBER PARAMETER DESCRIPTIO...

Page 12: ...se led should start to flash if they are the wrong way around turn power off to the operator wait until the inverter powers down then swap over any 2 of the motor phase wire at the inverter Turn power...

Page 13: ...Gate Drive Systems Australia Gate Drive Systems Australia DELTA VDF EL ATA CB 6 DELTA VDF EL DELTA VDF EL ATA CB 6...

Page 14: ...pened by hand To re engage the clutch move the gate by hand Into approx The half way position and turn the Knurled knob clockwise until it is very tight If when turning the knurled knob clockwise and...

Page 15: ...l not run inadvertently Gate rolls freely when in manual Gate wheels and guide rollers in good condition Gate stops are installed and in good condition not loose Gate rack is tight correct clearances...

Page 16: ...ty is negated and will not apply in the following circumstances i If no proof of date of purchase can be produced ii If the product has been used in a manner beyond its design parameters iii If the pr...

Reviews: