2
3
end
NEW
PRG
=
5
sec
PRG
2
OLD
PRG
(x
1
)
3
On the NEW transmitter:
hold down
the button and
release it after
5
seconds
;
count 2 movements.
On the OLD transmitter:
press and
release the button (
1 time
);
count
3 movements (= transmitter
memorised)
. If the system makes 6
movements (= memory locked or full,
transmitter not memorised).
A.6.1.
B
- Procedure for transmitters without the “PRG” and “ESC” buttons”
1
2
3
NEW
=
8
sec
OLD
(x
3
)
On the NEW transmitter:
hold down the but-
ton and
release it after
8 sec-
onds
;
On the OLD transmitter:
press and release the but-
ton (
3 times
), provided the button is memorised.
3
end
NEW
(x
1
)
3
On the NEW transmitter:
press and
release the button (
1 time
);
count
3 movements (= transmitter memorised)
. If
the system makes 6 movements (= memory locked or
full, transmitter not memorised).
A.6.2 - To memorise the transmitter buttons in “Mode II” (“Custom mode”)
• Procedures A.6.2
A
and A.6.2.
B
memorise a single button on the
new
transmitter in Mode II; i.e. they associate with the button (chosen by the installer) one of the
commands in the motor’s “list of commands” (for details on “Mode II” see section 4.4.1-B).
• Procedures A.6.2
A
and A.6.2.
B
memorise a single button. Repeat this operation to memorise another button.
A.6.2.
A
- Procedure for transmitters equipped with the “PRG” and “ESC” buttons (“ERA P” and “ERA W”)
1
2
continues
OLD
PRG
2
1
sec.
2
PRG
NEW
PRG
=
5
sec
On the OLD transmitter:
Hold
down the button and wait...
count 2 movements;
wait
again...
count 2 more move-
ments;
release the but-
ton.
On the NEW transmitter:
hold down the but-
ton and
2
3
continues
PRG
2
Select the desired
option and pro-
gram it
as follows
OLD
(x
...
)
4 OPTIONS:
1 press
= Open > Stop > Close > Stop > ...
2 presses
= Open
3 presses
= Close
4 presses
= Stop
release it after
5 seconds
;
count 2 movements.
On the OLD transmitter:
Press and release the button
the number of times
indicated
in the option you have chosen;
3
4
end
7
sec.
?
n
NEW
=
5
sec
...
...
3
After about 7 seconds, the motor performs a
number of
movements
equal to the number
of pulses entered.
On the NEW transmitter:
select the button
you want to memorise; hold it down and
release it after
5
seconds
;
count
3 movements (= transmitter memo-
rised)
. If the system makes 6 movements (= mem-
ory locked or full, transmitter not memorised).