INSTALLATION ALTERNATIVE
NOTE
This is the outline diagram. Actual installations
must be planned according to applicable
standards.
VPB S/ VPBS S can be installed in several different ways,
some of which are shown here.
Further option information is available at
and in the respective assembly instructions for the heat
sources used.
To external heat source
VPBS S300 can be docked to an external heat source,
e.g. a stove with a back boiler or a thermal solar install-
ation.
Install as follows:
• sensor for external heat source, tank (BT54)
• pressure gauge
• expansion vessel
• pressure relief valve
• AXC module
• circulation pump
• sensor, external heat source (BT53)
P
XL14
XL13
Connecting hot water circulation (VVC)
VPB S/ VPBS S stainless steel and enamel have a con-
nection that allows hot water circulation, the HWC return
is connected to this (XL5).
Hot water circulation
A circulation pump can be controlled by a ground-source
heat pump or exhaust air heat pump, indoor module or
control module for circulation of the hot water. The cir-
culating water must have a temperature that prevents
bacterial growth and scalding, and national standards
must be met.
-QZ1-FQ3
-QZ1-GP11
-QZ1-RM1
-QZ1-RN1
-QZ1
XL5
13
Chapter 3 | For the Installer
NIBE VPB S/ VPBS S
Summary of Contents for VPB S Series
Page 1: ...CHB EN 2126 2 531224 USER AND INSTALLER MANUAL Water heater Accumulator tank NIBE VPB S VPBS S...
Page 2: ......
Page 20: ......
Page 21: ......
Page 22: ......