Electrical installation
VPA 200/70 can be supplemented with an electric immer-
sion heater. Connection size R50. Max immersion heater
length 540 mm. Remove the lower front cover at installa-
tion.
Maintenance
The safety valve must be checked regularly, about four
times a year. If this does not happen then the safety valve
may malfunction and must be changed. The safety valve
sometimes releases a little water after hot water has been
tapped. This is because the cold water, which enters the
water heater to replace the hot water, expands when
heated causing the pressure to rise and the safety valve
to open.
Emptying
Draining the water heater takes place through the siphon
(with a hose) in the cold water connection (1). Drain the
boiler water section through the siphon (with a hose) on
the docking connection, outgoing to the external heat
source (4).
Hot water capacity
T50 minutes
NL number
Charge power
195
1,5
4 kW
170
1,5
5 kW
140
1,75
7 kW
150
1,75
8.5 kW
133
1,75
10 kW
Technical specifications
205
litre
Volume
66
litre
Volume, outer jacket
150
kg
Net weight
8,2
kW
Heat transfer (55/45 10/45°C)
9,0
kWh
Heat content at 50 °C
260
litre
Equivalent amount of hot water (40°C)
540
mm
Max. immersion heater length
2,5
(bar)
Max pressure, primary side
9,0
(bar)
Max pressure, water heater
088 650
Part No.
Energy labelling
NIBE
Supplier
VPA 200/70
Model
E
Energy efficiency class
150
W
Heat loss
271
l
Volume
Recovery
Leave the disposal of the packaging to the installer
who installed the product or to special waste
stations.
Do not dispose of used products with normal
household waste. It must be disposed of at a
special waste station or dealer who provides this type of
service.
Improper disposal of the product by the user results in
administrative penalties in accordance with current legis-
lation.