General
This accessory is used to dock a solar installation to a
VVM 310. The solar heat can be used for hot water,
heating the building and pool heating.
NOTE
When this accessory is installed and activated
the temperature in the indoor module vessel
is limited to about 85 °C. Therefore, temperat-
ure settings regarding hot water or heating
must not exceed 85 °C.
Contents
Heating pipe paste
2 x
Insulation tape
2 x
Unit box
1 x
Aluminium tape
2 x
Cable ties
4 x
Temperature sensor
1 x
Temperature sensor for solar panel
1 x
Cover discs
2 x
Component positions
LEK
AA5-X4
AA5-S2
AA5-X2
AA5-X9
X1
FA1
AA5-F1
AA5
Electrical components
Miniature circuit-breaker. 10A
FA1
Terminal block, power supply
X1
Accessory card
AA5
Terminal block, sensors and external bloc-
king
AA5-X2
Terminal block, communication
AA5-X4
Terminal block, circulation pump, mixing
valve and auxiliary relay
AA5-X9
DIP switch
AA5-S2
Fine wire fuse, T4AH250V
AA5-F1
Designations in component locations according to
standard IEC 81346-1 and 81346-2.