Main unit
Heat pump 2
Heat pump 3
Connecting accessories
Instructions for connecting accessories are provided in
the manual accompanying the accessory. See section
"Accessories" for a list of the accessories that can be
used with S1255. Connection for communication with
the most common accessories is shown here.
Accessories with accessory board (AA5)
Accessories with accessory board (AA5) connect to
terminal block AA2-X30:1,3,4 in S1255. Use cable type
LiYY, EKKX or equivalent.
If several accessories are to be connected, connect the
first accessory board directly to the terminal block in
S1255. Other accessory boards are connected to the
first in series.
Because there can be different connections for accessor-
ies with accessory board (AA5), you should always read
the instructions in the manual for the accessory that is
to be installed.
B
A
G
N
D
+1
2
V
AA2-X30
1
2
3
4
AA5-X4
1
2
3
4
5
6
7
8
A
B
GND
A
B
GND
AA5-X4
1
2
3
4
5
6
7
8
A
B
GND
A
B
GND
Accessory 1
S1255
Accessory 2
SELECTABLE OUTPUTS/INPUTS
On the PCB (AA2), S1255 has software-controlled AUX
inputs and outputs for connecting the external switch
function (contact has to be potential free) or sensor.
Go into menu 7.4 "Selectable in/outputs" on the display
to select to which AUX connection each function con-
nects.
Selectable inputs for these functions are AA2-X28:3-11.
Each function connects to any input and GND (AA2-X29).
6
7
8
5
4
3
AU
X4
AU
X5
AU
X6
AU
X3
AU
X2
AU
X1
AA2-X28
AA2-X29
GND
S1255 External
The example above uses the inputs AUX1 (AA2-X28:3) and AUX2
(AA2-X28:4).
A selectable output is AA2-X27.
For certain functions, accessories may be required.
TIP
Some of the following functions can also be
activated and scheduled via menu settings.
Possible selection for AUX inputs
Temperature sensor
Temperature sensor can be connected to S1255. Use
a 2-core cable of at least 0.5 mm² cable area.
Available options are:
• Boiler (BT52) (only shown if shunt-controlled additional
heat is selected in menu 7.2.1)
• cooling/heating (BT74), determines when it is time to
switch between cooling and heating mode (only
shown if cooling accessory is selected in menu 7.2.1).
Monitor
Available options are:
• alarm from external units. The alarm is connected to
the control, which means that the malfunction is
presented as an information message in the display.
Potential-free signal of type NO or NC.
• level (accessory NV10)/, pressure/flow monitor for the
brine (NC).
External activation of functions
An external switch function can be connected to S1255
to activate various functions. The function is activated
during the time the switch is closed.
Possible functions that can be activated:
• forced control of brine pump
• hot water demand mode "more hot water"
• hot water demand mode "small"
23
Chapter 5 | Electrical connections
NIBE S1255