PROGRAM SETTINGS
MENU SETTINGS
Menu 1.1.1, 1.1.2 - Heating and cooling
Set the temperature (with room sensor installed and
activated):
Heating
Setting range: 5 – 30 °C
The value in the display appears as a temperature in °C,
if the zone is controlled by a room sensor.
Caution
A slow heating system such as underfloor
heating may be inappropriate for controlling
with room sensors.
Menu 1.1.3 - Humidity
Setting range: 30 – 90%
This menu is shown if the accessory is installed and has
been activated in menu 7.1.6.4 - "Limit humidity in heat".
Here, you set the desired value for relative humidity
(RH).
Menu 1.3 - Room sensor settings
Here, you make your settings for room sensors and
zones. The room sensors are grouped by zone.
Here, you select the zone to which a sensor will belong.
It is possible to connect multiple room sensors to each
zone. Each room sensor can be given a unique name.
The control of heating, humidity and ventilation are ac-
tivated by checking each option. Which options are
shown depends on which type of sensor is installed. If
control is not activated, the sensor will be the displaying
sensor.
Caution
A slow heating system such as underfloor
heating may be inappropriate for controlling
with room sensors.
Menu 1.3.3 - Room sensor settings
Name room sensor
Enter a name for the relevant room sensor.
Control room sensor
Setting range: on/off
Here, you select the zone to which a sensor will belong.
It is possible to connect multiple room sensors to each
zone. Each room sensor can be given a unique name.
The control of heating, humidity and ventilation are ac-
tivated by checking each option. Which options are
shown depends on which type of sensor is installed. If
control is not activated, the sensor will be the displaying
sensor.
Caution
A slow heating system such as underfloor
heating may be inappropriate for controlling
with room sensors.
Menu 1.3.4 - Zones
Here, you add and name zones. You also select the cli-
mate system to which a zone is to belong.
Menu 5.4 – Wireless devices
In this menu you connect wireless units, and manage
settings for connected units.
Add the wireless unit by pressing "add unit". For the
quickest identification of wireless unit, it is recommen-
ded that you put your master unit in search mode first.
Then put the wireless unit in identification mode.
Menu 7.1.4.4 - Demand-controlled ventilation
Humidity controlled ventilation
Alternative: on/off
Highest fan speed
Setting range: 1 – 100%
Lowest fan speed
Setting range: 1 – 100%
Time interv. change of fan speed
Setting range: 1 – 60 minutes
Controlling zones
Activate zones for demand-controlled ventilation.
Here, you make settings for demand-controlled ventila-
tion.
The speed of the fan can be changed depending on the
humidity in the air.
Menu 7.1.6.4 - Limit RH in heat
Here you can activate Humidity control, controlled by
the relative humidity (RH) of the air, during heating oper-
ation. Only shown if a moisture sensor is installed
Menu 7.1.7.2 - Humidity control
Only shown if a moisture sensor is installed and cooling
is activated.
Prevent condensation in cold
Setting range: on/off
Limit RH in cold
Setting range: on/off
ROT 10 | GB
16
Summary of Contents for ROT 10
Page 2: ......
Page 10: ...TEKNISKA DATA ROT 10 067724 Art nr 86x86x11 mm M tt BxHxD ROT 10 SE 10...
Page 18: ...TECHNICAL SPECIFICATIONS ROT 10 067724 Part No 86x86x11 mm Dimensions WxHxD ROT 10 GB 18...
Page 28: ...TECHNISCHE DATEN ROT 10 067724 Art nr 86x86x11 mm Abmessungen BxHxT ROT 10 DE 28...
Page 35: ...TEKNISET TIEDOT ROT 10 067724 Tuotenumero 86x86x11 mm Mitat LxKxS 35 ROT 10 FI...
Page 36: ......
Page 37: ......
Page 38: ......