![Nibe ROT 10 Manual Download Page 13](http://html1.mh-extra.com/html/nibe/rot-10/rot-10_manual_1686505013.webp)
CLIMATE SYSTEMS AND ZONES
Multiple climate systems are used when different supply
temperatures are required for different parts of the
system, for example when both underfloor heating and
radiators are fitted in a property.
A climate system can be divided up into several zones,
which can be allocated one or more sensors or other
accessories. A zone could be a specific room or part of
larger premises.
Climate system 2
Climate system 1
Zone 1
Zone 3
Zone 2
ROT 10
Room sensor
Room
sensor
Room sensor
The example shows a property with two climate sys-
tems. Climate system 1 is a radiator system with two
zones. Zone 1 is the controlling zone, and there is one
ROT 10 and one room sensor installed, which means
that the heat pump extracts the heat from the stove
more rapidly. Zone 2 is the zone displayed, which means
that the temperature and humidity can be read off in the
myUplink app or via myuplink.com.
Climate system 2 is an underfloor heating system with
one zone, which is the controlling zone.