Installation and positioning
100
112
105
92
108
850
900
1000
1000
1000
1050
1050
900
900
950
950
950
800
800
850
88
South
The diagram above shows solar radiation in percentage
of global radiation in relation to some differently ori-
entated and angled surfaces.
The map shows lines with the same global radiation,
that is the solar radiation measured at horizontal sur-
faces. Source: SMHI.
Using the diagram and the map, one can estimate the
annual value of the solar radiation falling on those
surfaces where the solar panels are located.
100% is the solar radiation falling on a horizontal sur-
face, which in southern Sweden lies between 900 and
1050 kWh/year. The angle of inclined surfaces is 45°.
1. Calculate the annual solar radiation using the map.
The specific solar radiation for the installation is
obtained as a percentage, based on the location
of the solar panel according to the diagram.
2. Multiply the result by the installation's peak output
(3.12, 5.72, 9.36 kW).
3. Multiply the result 2 by a constant 0.9 to calculate
the energy production in kWh/year (with a reser-
vation for shade, dirt and snow coverage).
Example: Visby, 45°, installation south.
1050 x (112/100) x 3.12 x 0.9 = 3302 kWh/year