Connection of the circulation pump (GP9)
Connect the circulation pump (GP9) to AA5-X9:8 (230V),
AA5-X9:7 (N) and X1:3 (PE).
1
2
3
4
5
6
7
8
9
L
N
PE
3
2
1
1
2
3
4
5
6
7
8
9
3
2
1
Unit box External
GP9
AA5-X9
X1
Connection of reversing valve motor (QN19)
and charge pump, pool (GP12)
Connect the reversing valve motor (QN19) and the
charge pump (GP12) to an external junction box.
Connect the black cable from the reversing valve and
the brown cable from the charge pump together in the
junction box.
Connect the blue cable from the reversing valve and the
blue cable from the charge pump together in the junc-
tion box.
Connect the control cable from the junction box to AA5-
X9:6 (signal), AA5-X9:5 (N), AA5-X10:2 (230V) and
X1:3(PE). Connect the charge pump control signal to
AA5-X2:5-6.
2
1
1
2
3
4
5
6
7
8
9
3
4
5
6
1
2
3
2
1
Black
Blue
Brown
AA25
External
AA5-X9
QN19
AA5-X10
GP12
X1
AA5-X2
Blue
Brown
Blue
Brown
Yellow/green
Connection box
DIP switch
The DIP switch (S2) on the accessory card (AA5) must be
set as follows.
ON
1
2
3
4
5
6
7
8
Program settings
Program setting of POOL 310 can be performed via the
start guide or directly in the menu system.
Start guide
The start guide appears upon first start-up after heat
pump installation, but is also found in menu 5.7.
Menu system
If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
Menu 5.2 - system settings
Activating/deactivating of accessories.
Menu 4.1.1 - pool
Activating pool heating and setting start and stop tem-
perature.
Menu 5.1.11 - pump speed heating medium
Setting heating medium pump's speed.
Caution
Also see the Installer Manual for the indoor
module.
Technical data
Technical specifications
POOL 310
230V ~ 50 Hz
Voltage circulation pump
230V ~ 50 Hz
Voltage reversing valve
G1
Connection, pump
G1 x Ø 22
mm compres-
sion ring
Connection, ball valve
7,5
cw
s
value reversing valve
067 247
Part No.
POOL 310 | GB