NOTE

Any servicing must be carried out by a compet-
ent person.

Maintenanc

e

General

 

inspection

 - 

Check

 

the

 

following:

1.

Condition of casing.

2.

Electrical connections.

3.

Pipe connections.

Correct

 

any

 

fault

 

before

 

continuing.

 

NOTE

Do not remove or adjust any components that
are part of this pressurised water heater. Contact
your installer!

NOTE

If

 

this

 

pressurised

 

water

 

heater

 

develops a fault,

 

e.g. a

 

flow

 

of

 

hot

 

water

 

from

 

the

 

overflow

 

pipe,

 

turn

 

the

 

heat

 

pump

 

offand

 

contact

 

your

 

in-staller.

Cleaning

Inspect

 

and

 

clean

 

the

 

water

 

heater

 

by

 

using

 

a

 

suitable

 

instrument

 

such

 

as

 

an

 

endoscope.

 

The

 

hot

 

water

 

connec-tion

 

(XL4)

 

must

 

be

 

removed

 

to

 

facilitate

 

access.

Emptying

The

 

water

 

heater

 

is

 

emptied

 

through

 

the

 

drain cock

 

in

 

the

 

cold

 

water

 

connection

 

(XL3).

Drain

 

the

 

charge

 

coil

 

through

 

the

 

siphon

 

(with

 

hose)

 

on

 

the

 

docking

 

connection,

 

return

 

to

 

heat

 

pump

 

(XL9).

Drain

 

the

 

solar

 

coil

 

through

 

the

 

siphon

 

(with

 

hose)

 

on

 

the

 

connection, return to solar heating system (XL14).

Chapter 7 |

Service and maintenance

19

7 Service and maintenance

OPMERKING

Servicewerkzaamheden dienen uitgevoerd te 
worden door gekwalificeerd personeel.

NOTE

Tout les opérations de services doivent être 
effectué par une personne compétente.

Achtung
Jeder Service soll von einer  qualifizierten 
Person durchgeführt werden.

HUOM

Laitetta saa hoitaa vain sen toimintaan 
perehtynyt henkilö. Laitetta saa huoltaa vain 
ammattitaitoinen asentaja ja lämpöpumppua 
saa huoltaa vain sertifioitu asentaja. 
Sähköasennuksia saa huoltaa vain sertifioidun 
sähköasentajan valvonnassa.

OPMERKING

Indien deze onder druk staande boiler een mogelijk 
mankement vertoont, bijv. bij waterlekkage: zet de 
warmtepomp (of ketel) uit en raadpleeg uw installateur. 

NOTE

Si ce chauffe-eau tombe en panne, par exemple une fuite, 
arrêtez la pompe à chaleur, et contactez votre installateur.

ACHTUNG

Wenn es einen Fehler an Druck-Heißwasserbereiter gibt 
z.B.: Varmwasserausfluß aus Überlaufrohr schalten Sie die 
Wärmepumpe aus und treten Sie in Kontakt mit Ihrem 
Installateur.

HUOM

Mikäli tämä paineistettu vesivaraaja vikaantuu, mm. 
kuuma vesi virtaa ylivuotoputkesta, kytke 
lämpöpumppu pois päältä ja ota yhteys asentajaan

.

OPMERKING

Verwijder geen enkel onderdeel van deze onder 
waterdruk  staande  boiler.  Pas  ook  geen 
component aan. Raadpleeg bij vragen altijd uw 
installateur.

NOTE

N’enlever ou ajuster pas les composants qui 
font partie du chauffe-eau sous pression. 
Contactez votre installateur!

ACHTUNG

Keine Komponente, die ein Teil dieses Heiß-
wasserbereiter unter Druck sind, entfernen oder 
regulieren. Tritt in Kontakt mit Ihrem Installateur!

HUOM

Älä poista tai muuta mitään osaa, joka on 
kuuluu tähän paineistettuun vesivaraajaan. Ota 
yhteys asentajaan!

C-C ( 1 : 7 )

C

C

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A

A

B

B

C

C

D

D

E

E

F

F

Tegn, nr:

Erstatning for:

Filenavn:

Erstatt av:

Rev.

Målestokk:

Gen tol:

NS-ISO 2768  (Middels)

Kontrollert

Kontroll

Dato

Konstr./ Tegnet

Godkjent

Varenummer:

1-115-001

09.05.2011

R-E N

 

 

 

 

 

 

HA-WH 5030 F.

 Megacoil 300L EU.

 

N:\Utvikling\Tegninger\Produkter\1 Beredere\115 Ny EU\1-115-001.idw

Trippeveien 5

1618 Fredrikstad

1113006802 

XL3

XL9

HA - 

WH5 F 160,

 200 & 300

HA - 

WH5 FS  200 & 300

Summary of Contents for HA-WH5 F

Page 1: ...INDIRECTLY HEATED DOMESTIC HOT WATER CYLINDERS FOR HEAT PUMPS AND OTHER ENERGY SOURCES HA WH5 F FS INSTALLER MANUAL 1 EDITION 30 03 2015...

Page 2: ...HA WH 5016 F HA WH 5020 F HA WH 5030 F HA WH 5020 FS HA WH 5030 FS...

Page 3: ...Dimensions andpipe connections Overall dimensions Heat pump Solar Cold and hot water 13 Docking 13 5 Electrical installation 15 Sensors 15 Temperature limiter 16 6 Commissioning and adjusting 17 17 Fi...

Page 4: ...install Use only manufacturer s recommended replacement parts Benchmark places responsibilities on both manufacturers and installers the purpose is to ensure that customers are provided with the corr...

Page 5: ...carried out by a suitably d person Date Signature Notes Description Hot water page 14 Shut valves Expansion vessel T P valve Tundish Cold water page 13 and 14 Shut valves Non return valve Mixing valv...

Page 6: ...and stable set up Pipes must be routed from the safety valve to a suit able drain The water heater s installation area should always have a temperature of at least 10 C and max 30 C Chapter 2 Deliver...

Page 7: ...160 200 300 L HA WH5 FS 200 300 L 3 3 4 4 5 5 6 6 7 7 Gen tol NS ISO 2768 Midd Kontrollert Kontroll Dato Konstr Tegnet Godkjent Varenummer 09 05 2011 R E N HA WH 5030 F Megacoil 300L EU 1113006802 BT7...

Page 8: ...T7 BT6 UA3 Electrical components Miscellaneous Serial number plate Adjustable feet PF 3 PF 4 UL Designations in component locations according to standard IEC 81346 1 and 81346 2 or another external he...

Page 9: ...Chapter 4 Pipe connections 9 in areas of hard water as the operating Megacoil Megacoil Solar Coil Emptying the system by 1 Open external r valve and external drain valve 2 Flush the system for some m...

Page 10: ...ine 10 Chapter 4 Pipe connections Dimensions pipe connections and setting out coordinates MEGACOIL 160 200 300 MEGACOIL SOLAR 200 300 HA WH5 F 160 200 300 HA WH5 FS 200 300 3 3 4 4 5 5 6 6 7 7 Gen t N...

Page 11: ...20x1 5mm M mut 1 12 Lokk NIBE lysgr med hull 1 11 Skumpakning 20 80 8 10 O ring 29 2x3mm 1 9 2 R r Nippel Overgang G1 22mm 1 9 1 R RNIPPEL OVERG 1 22 MS 1 9 Skumspakning el lokk 1 8 Thermodisc 300075...

Page 12: ...olar power and heat pump The solar heating system s supply and return are connected to the Titanium Megacoil Solar Coil 12 Chapter 4 Pipe connections Except 160 litre A 4 5 6 7 274 200L 398 300L 121 3...

Page 13: ...latory hot water pipes Adjust the hot water system so that the temperature does not fall below 50 C at the ends of the system Docking HA WH5 FS 200 300 can be connected in several different ways one o...

Page 14: ...14 Chapter 4 Pipe connections To air water heat pump Titanium Megacoil Megacoil Solar can be docked with heat pump for example NIBE air water heat pump P P P P BT12 AA25 EB1 BT3 BT1 To solar heating H...

Page 15: ...vision of a qualified electrician Electrical installation and wiring must be carried out in accordance with the stipulations in force Achtung Die elektrische Installation und Service m ssen unter eine...

Page 16: ...supply to temperature limiter FD1 is 230 V Temperature limiter wiring diagram 16 Chapter 5 Electrical installation Immersion heater wiring diagram Megacoil Solar Models Megacoil Models HA WH5 FS 200 3...

Page 17: ...charge coil Filling and venting 1 Open the g valve external not included with the product Fill the coil in the hot water heater and the rest of the climate system with water 2 Vent the coil of the cli...

Page 18: ...urn line solar heating system XL14 Titanium Megacoil Solar 200 18 Chapter 6 Commissioning and adjusting Titanium Megacoil Solar 300 Titanium Megacoil 300 Pressure drop Flow Flow Pressure drop Flow Pre...

Page 19: ...S hk asennuksia saa huoltaa vain sertifioidun s hk asentajan valvonnassa OPMERKING Indien deze onder druk staande boiler een mogelijk mankement vertoont bijv bij waterlekkage zet de warmtepomp of ket...

Page 20: ...5 litre Volume charge coil 45 59 kg Net weight 224 330 kg 190 5 Gross weight 150 83 9 214 79 litre 126 9 85 5 8 16 12 58 kWh 6 89 Heat content at 50 C 234 361 litre 198 Equivalent amount of hot water...

Page 21: ...59 kW 24Hrs Heat loss t 45 C 75 C Max operating temperature 3 0 3 bar MPa Max pressure primary side 10 1 0 bar MPa Max pressure water heater 3 0 3 bar MPa Maximum pressure solar coil 10 1 0 bar MPa M...

Page 22: ...t information 4 Safety information 4 Inspection of the installation 5 Installation alternative 13 To ground source heat pump 14 M Maintenance 19 General inspection 19 P Pipe connections 9 Cleaning the...

Page 23: ......

Page 24: ...aller manual COIL SOLAR COIL HOT WATER HEATER NIBE Energy Systems Box 14 Hannabadsv gen 5 S 28521 MARKARYD SWEDEN Phone 0046 433 73000 Fax 0046 433 73190 info nibe se www nibe se...

Reviews: