Nibe HA-WH5 F Installer Manual Download Page 12

Heat

 

pump connections

Connecting

 

to

 

heat

 

pump

 or another external heat source

The

 

heat

 

pump

 

supply

 

and

 

return

 

are

 

connected

 

to 

HA - WH5 F

.

Solar connections

Connecting

 

to

 

solar

 

power

heat pump

 or external heat source

The

 

solar

 

heating

 

system's

 

supply

 

and

 

return

 

are

 

connected

 

to

 

the 

HA - WH5 FS

.

12

Chapter 4 |

Pipe connections

T&P valve

Install the pipe for the T&P valve as illustrated on page 9.

Heat pump connections

Connecting to heat pump

The heat pump supply and return are connected to Titanium Megacoil.

Solar connections

Connecting to solar power and heat pump

The solar heating system's supply and return are connected to the Titanium Megacoil- Solar Coil.

12

Chapter 4 |

Pipe connections

(Except 160 litre)

A-A ( 1:8 )

A

A

 

 

Følerlomme 50mm m/ Nippel M12

2

21

711344122

Plastikk

Dekkskive Hvit 24x51mm   PP TPE 

1

20

 

 

Følerlomme 120mm / Nippel M12

1

19

711270091

EPS

Skumspakning el-lokk

1

18

711344060

PP

Sealing 3/4" Light grey

1

17

711344057

PP

Sealing 1/2" Light grey

2

16

711239943

Plastikk

Dekkskive hvit ø21-ø50

4

15

711270011 

/ 711270012

PP

PG-Nippel Ø10/M16x1,5mm M/mutter

1

14

71

12

ABS Plastic

PG-Nippel ø13,  M20x1,5mm M/mutter

1

13

711344029

ABS/PMMA

Lokk, NIBE, lysgrå, med hull.

1

12

711270084

Skumgummi

Skumpakning ø20/ø80

10

11

711239910

EPDM 70

O ring 29,2x3mm

1

10.2

711230911

Messing

Rør Nippel Overgang G1" ø22mm

1

10.1

711290911

 

RØRNIPPEL OVERG. 1"Ø22    MS

1

10

711279919

N/A

 Thermodisc (300075)(4011)

1

9

711344071

Generic

Thermodisc. 66TM, Temp. 85 ±3° C

1

8

711279918

N/A

 Thermodisc (300155)(4114)

1

7

711300038

N/A

O-Ring, 38x3,2mm

1

6

8025403

CW602N

Element  1.1/4 "  3 kW 230/400V, SMO, 

1.4547

1

5

3-020-098

Hvitlakkert

Y-Sarie 300LMegacoil-Solar

1

4

711231013

 

Plastbunn, ø580 Lys. m/ben

1

3

308060

PP

Plast-topp, lys grå Mecacoil solar EU.

1

2

1-114-002

 

HA-WH 5030 FS, Megacoil / Solar 300L.

1

1

Stykkliste

V.nr.-Tegn.

Materiale

Beskrivelse

Ant.

Pos.

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A

A

B

B

C

C

D

D

E

E

F

F

Tegn, nr:

Erstatning for:

Filenavn:

Erstatt av:

Rev.

Målestokk:

Gen tol:

NS-ISO 2768  (Middels)

Kontrollert

Kontroll

Dato

Konstr./ Tegnet

Godkjent

Varenummer:

1-114-001

09.02.2011

R-E N

 

 

1248-001

 

1:8

 

HA-WH 5030 FS.

 Megacoil / Solar 300L, EU.

 

N:\Utvikling\Tegninger\Produkter\1 Beredere\114 Ny EU m 2,Spi\1-114-001.idw

Trippeveien 5

1618 Fredrikstad

1113006804

12

13

2

5

6

1

27

(2

00

L)

39

(3

00

L)

41

(2

00

L)

76

(3

00

L)

41

(2

00

L)

42

(3

00

L)

42

  (

20

0L

)

10

19

 (3

00

L

12

1

16

11

16

17

11

35

 (2

00

L)

16

09

 (3

00

L)

3/4" F. Cold inlet.

Solar sensor

1/2" F

Temp. sensor

BT 6

1/2" F

Ø22mm(4x)

585

97

,2

97,2

14

Primary return.

Heat Pump.

Ø22mm

Primary flow.

Solar.

Ø22mm

Primary return.

Solar.

Ø22mm

13

7,

5

137,5

11

3

15

4

Temp. sensor

       BT 7

     1/2" F

13

0

585

Ø

17

16

High temp limite

motorized valve

solar.

High temp limiter

motorized valve

thermostat optiond

Thermostat and

high temp limiter

for immersed heat.

 

Primary flow

Heat Pump.

Ø22mm

21

Immersion

heater.

20

0-

45

1/2"

10.1

10.2

Hot outlet

Ø22mm

137,5

B-B ( 1:8 )

711344122

Plastikk

Dekkskive Hvit 24x51mm   PP TPE 

2

19

 

 

Følerlomme 50mm m/ Nippel M12

1

18

 

 

Følerlomme 120mm / Nippel M12

1

17

711344060

PP

Sealing 3/4" Light grey

1

16

711344057

PP

Sealing 1/2" Light grey

1

15

711239943

Plastikk

Dekkskive hvit ø21-ø50

2

14

711270011 

/ 711270012

PP

PG-Nippel Ø10/M16x1,5mm M/mutter

1

13

711290011 

ABS Plastic

PG-Nippel ø13,  M20x1,5mm M/mutter

1

12

711344029

ABS/PMMA

Lokk, NIBE, lysgrå, med hull.

1

11

711270084

Skumgummi

Skumpakning ø20/ø80

8

10

711239910

EPDM 70

O ring 29,2x3mm

1

9.2

711230911

Messing

Rør Nippel Overgang G1" ø22mm

1

9.1

711290911

 

RØRNIPPEL OVERG. 1"Ø22    MS

1

9

711270091

EPS

Skumspakning el-lokk

1

8

711279919

N/A

 Thermodisc (300075)(4011)

1

7

711300038

N/A

O-Ring, 38x3,2mm

1

6

8025403

CW602N

Element  1.1/4 "  3 kW 230/400V, SMO, 

1.4547

1

5

3-020-096

Hvit Lakkert

Ytterplate Megacoil UK 300L  Stanset 

Hvit

1

4

711231013

 

Plastbunn, ø580 Lys. m/ben

1

3

3-008-061

PP

Plasttopp ø580 lys grå med 5 stk. hull.

1

2

1-115-002

 

300L, Megacoi, EU.

1

1

Stykkliste

V.nr.-Tegn.

Materiale

Beskrivelse

Ant.

Pos.

B

B

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A

A

B

B

C

C

D

D

E

E

F

F

Tegn, nr:

Erstatning for:

Filenavn:

Erstatt av:

Rev.

Målestokk:

Gen tol:

NS-ISO 2768  (Middels)

Kontrollert

Kontroll

Dato

Konstr./ Tegnet

Godkjent

Varenummer:

1-115-001

09.05.2011

R-E N

 

 

1252-001

 

1:8

 

HA-WH 5030 F.

 Megacoil 300L EU.

 

N:\Utvikling\Tegninger\Produkter\1 Beredere\115 Ny EU\1-115-001.idw

Trippeveien 5

1618 Fredrikstad

1113006802 

137,5 137,5

12

2

  9

71

 (1

60

L)

11

29

 (2

00

L)

16

08

 (3

00

L)

4

97,2

Temp. sensor

       BT 6

     1/2" F

3/4" F. Cold inlet.

Primary return.

Heat Pump.

Ø22mm

Temp. sensor

       BT 7

      1/2" F

Primary flow.

Heat Pump.

Ø22mm

15

5

18

0

11

12

3

51

(1

60

L)

54

(2

00

L)

73

(3

00

L)

13

14

1

8

9.1

10

Secondary return.

1/2" F

Hot outlet

Ø22mm

Thermostat and

temp limiter

immersion heater.

Immersion

heater.

585

Ø

16

15

9.2

5

6

18

2

19

97

,2

13

7,

5

0-

45

7

15

77

18

0

Summary of Contents for HA-WH5 F

Page 1: ...INDIRECTLY HEATED DOMESTIC HOT WATER CYLINDERS FOR HEAT PUMPS AND OTHER ENERGY SOURCES HA WH5 F FS INSTALLER MANUAL 1 EDITION 30 03 2015...

Page 2: ...HA WH 5016 F HA WH 5020 F HA WH 5030 F HA WH 5020 FS HA WH 5030 FS...

Page 3: ...Dimensions andpipe connections Overall dimensions Heat pump Solar Cold and hot water 13 Docking 13 5 Electrical installation 15 Sensors 15 Temperature limiter 16 6 Commissioning and adjusting 17 17 Fi...

Page 4: ...install Use only manufacturer s recommended replacement parts Benchmark places responsibilities on both manufacturers and installers the purpose is to ensure that customers are provided with the corr...

Page 5: ...carried out by a suitably d person Date Signature Notes Description Hot water page 14 Shut valves Expansion vessel T P valve Tundish Cold water page 13 and 14 Shut valves Non return valve Mixing valv...

Page 6: ...and stable set up Pipes must be routed from the safety valve to a suit able drain The water heater s installation area should always have a temperature of at least 10 C and max 30 C Chapter 2 Deliver...

Page 7: ...160 200 300 L HA WH5 FS 200 300 L 3 3 4 4 5 5 6 6 7 7 Gen tol NS ISO 2768 Midd Kontrollert Kontroll Dato Konstr Tegnet Godkjent Varenummer 09 05 2011 R E N HA WH 5030 F Megacoil 300L EU 1113006802 BT7...

Page 8: ...T7 BT6 UA3 Electrical components Miscellaneous Serial number plate Adjustable feet PF 3 PF 4 UL Designations in component locations according to standard IEC 81346 1 and 81346 2 or another external he...

Page 9: ...Chapter 4 Pipe connections 9 in areas of hard water as the operating Megacoil Megacoil Solar Coil Emptying the system by 1 Open external r valve and external drain valve 2 Flush the system for some m...

Page 10: ...ine 10 Chapter 4 Pipe connections Dimensions pipe connections and setting out coordinates MEGACOIL 160 200 300 MEGACOIL SOLAR 200 300 HA WH5 F 160 200 300 HA WH5 FS 200 300 3 3 4 4 5 5 6 6 7 7 Gen t N...

Page 11: ...20x1 5mm M mut 1 12 Lokk NIBE lysgr med hull 1 11 Skumpakning 20 80 8 10 O ring 29 2x3mm 1 9 2 R r Nippel Overgang G1 22mm 1 9 1 R RNIPPEL OVERG 1 22 MS 1 9 Skumspakning el lokk 1 8 Thermodisc 300075...

Page 12: ...olar power and heat pump The solar heating system s supply and return are connected to the Titanium Megacoil Solar Coil 12 Chapter 4 Pipe connections Except 160 litre A 4 5 6 7 274 200L 398 300L 121 3...

Page 13: ...latory hot water pipes Adjust the hot water system so that the temperature does not fall below 50 C at the ends of the system Docking HA WH5 FS 200 300 can be connected in several different ways one o...

Page 14: ...14 Chapter 4 Pipe connections To air water heat pump Titanium Megacoil Megacoil Solar can be docked with heat pump for example NIBE air water heat pump P P P P BT12 AA25 EB1 BT3 BT1 To solar heating H...

Page 15: ...vision of a qualified electrician Electrical installation and wiring must be carried out in accordance with the stipulations in force Achtung Die elektrische Installation und Service m ssen unter eine...

Page 16: ...supply to temperature limiter FD1 is 230 V Temperature limiter wiring diagram 16 Chapter 5 Electrical installation Immersion heater wiring diagram Megacoil Solar Models Megacoil Models HA WH5 FS 200 3...

Page 17: ...charge coil Filling and venting 1 Open the g valve external not included with the product Fill the coil in the hot water heater and the rest of the climate system with water 2 Vent the coil of the cli...

Page 18: ...urn line solar heating system XL14 Titanium Megacoil Solar 200 18 Chapter 6 Commissioning and adjusting Titanium Megacoil Solar 300 Titanium Megacoil 300 Pressure drop Flow Flow Pressure drop Flow Pre...

Page 19: ...S hk asennuksia saa huoltaa vain sertifioidun s hk asentajan valvonnassa OPMERKING Indien deze onder druk staande boiler een mogelijk mankement vertoont bijv bij waterlekkage zet de warmtepomp of ket...

Page 20: ...5 litre Volume charge coil 45 59 kg Net weight 224 330 kg 190 5 Gross weight 150 83 9 214 79 litre 126 9 85 5 8 16 12 58 kWh 6 89 Heat content at 50 C 234 361 litre 198 Equivalent amount of hot water...

Page 21: ...59 kW 24Hrs Heat loss t 45 C 75 C Max operating temperature 3 0 3 bar MPa Max pressure primary side 10 1 0 bar MPa Max pressure water heater 3 0 3 bar MPa Maximum pressure solar coil 10 1 0 bar MPa M...

Page 22: ...t information 4 Safety information 4 Inspection of the installation 5 Installation alternative 13 To ground source heat pump 14 M Maintenance 19 General inspection 19 P Pipe connections 9 Cleaning the...

Page 23: ......

Page 24: ...aller manual COIL SOLAR COIL HOT WATER HEATER NIBE Energy Systems Box 14 Hannabadsv gen 5 S 28521 MARKARYD SWEDEN Phone 0046 433 73000 Fax 0046 433 73190 info nibe se www nibe se...