Start-up and
inspection
NOTE
There must be water in the climate system
before FLM S45 is started.
LE
K
SF2
SF1
START-UP WITH COMPATIBLE HEAT PUMP
1.
Set the main switch (SF1) and the switch for the
circulation pump (SF2) on FLM S45 to position "1".
2.
Start the heat pump.
3.
Follow the instructions in the display’s start guide.
If the start guide does not start when you start the
heat pump, you can start it manually in menu 7.7.
4.
Check that the fan (GQ2) and circulation pump (GP2)
are running.
STARTING-UP WITH ANOTHER HEAT PUMP
1.
Set the main switch (SF1) and the switch for the
circulation pump (SF2) on FLM S45 to position “1”.
2.
Check that the fan (GQ2) and the circulation pump
(GP2) are in operation.
3.
Set the speed of the fan using the potentiometer
(SF3).
4.
Start the heat pump.