30
NIBE FIGHTER 120
Miscellaneous
Technical specifications
,3
Height
600 mm
Width
600 mm
Depth
456 mm
Net weight
38 kg
Supply voltage
230 V~ 1-phase + N
Rated output, compressor
245 W
Rated output, circulation pump
10 W
Driving power fan (DC)
25 – 110 W
Enclosure class
Drip proof IP21
Max sound level at 260 m³/h
45 dBA
Refrigerant amount
470 g
Refrigerant type
R134a
Break pressure high pressure pressostat
2,0 MPa (20.0 (bar)
Max flow line temperature, compressor
65 °C
Connection, flow line (white)
15 mm*
Connection, return line (blue)
15 mm*
Technical specifications
Volume
150 l
300 l
Height
840 mm
1 550 mm
Diameter
596 mm
Net weight
31 kg
53 kg
Connection, hot water (red)
22 mm*
Connection, cold water/ HP return (blue)
28 mm*
Connection, HP front (white)
22 mm*
Hot water volumes:
Comfort mode
ECO
NORM
HIGH
ECO
NORM
HIGH
Volume 40 °C hot water**
> 90 l
180 l
200 l
> 90 l
385 l
425 l
* Compression ring coupling for 15 mm copper tube included.
** At 10 °C incoming cold water temperature.
Water heater