Indicates current hot water temperature. In ECO operating mode, the temperature is displayed according to the upper
hot water sensor (87) and in NORM and HIGH, the temperature is displayed according to the lower hot water sensor
(88).
Indicates the current status: RUN (Normal operation) / DEFROST (Defrosting mode) / LEGIO (Periodic hot water in-
crease activated) / MANUAL (Forced control activated).
The compressor’s stop temperature when comfort mode ECO is selected. Controlled by the upper hot water sensor
(87).
The compressor’s stop temperature when comfort mode NORM is selected. Controlled by the lower hot water sensor
(88).
The compressor’s stop temperature when comfort mode HIGH is selected. Controlled by the lower hot water sensor
(88).
The temperature as well as pump and fan speeds can be read off under the menu VIEW.
Indicates the hot water temperature in the upper section of the tank, sensor (87).
Indicates the hot water temperature in the lower section of the tank, sensor (88).
Indicates the flow line temperature from HP to water heater, sensor (89).
Indicates evaporation temperature, sensor (86).
Indicates the pump speed in percent, 0 to 100 %.
Indication of current fan speed: SLOW/MED/HIGH/REMOTE.
If the control knob is held in for longer than 5 seconds in this mode, the service menus are activated.
The time before the ventilation flow returns to normal flow after it is changed with the remote. When set at the fac-
tory setting, ”---”, the remote control changes are permanent.
The desired comfort mode for hot water production is selected here.
Selection of language.
Maximum hot water temperature in the water heater at the upper hot water sensor (87).
Temperature difference between start and stop of the compressor.
Minimum time between compressor starts.
Defrosting starts when the evaporation temperature becomes too low. The compressor stops and the ventilation flow
heats the evaporator until the defrosting time (DEF.TIME) has been exceeded and the evaporation temperature is
above 7 °C.
Defrosting time.
Fan speed during defrost.
How often the periodic hot water increase (legionella protection) is to be activated is set here.