op. mode 4.2
auto
manual
add. heat only
op. mode
Setting range: auto, manual, add. heat
only
Default value: auto
functions
Setting range: compressor, addition,
heating, cooling
The heat pump operating mode is usually set to "auto". It is also possible to set
the heat pump to "add. heat only", but only when an addition is used, or "manual"
and select yourself what functions are to be permitted.
Change the operating mode by marking the desired mode and pressing the OK
button. When an operating mode is selected, it shows what is permitted in the
heat pump (crossed out = not permitted) and selectable alternatives to the right.
To select selectable functions that are permitted or not, mark the function using
the control knob and press the OK button.
Operating mode auto
In this operating mode the heat pump automatically selects what functions are
permitted.
Operating mode manual
In this operating mode you can select what functions are permitted. You cannot
deselect "compressor" in manual mode.
Operating mode add. heat only
In this operating mode the compressor is not active, only additional heat is used.
Caution
If you choose mode "add. heat only" the compressor is deselected and
there is a higher operating cost.
Functions
"compressor"
is the unit that produces heating and hot water for the home. If
"compressor" is deselected in auto mode, this is displayed with a symbol in the
main menu. You cannot deselect "compressor" in manual mode.
"addition"
is the unit that helps the compressor to heat the home and/or the hot
water when it cannot manage the entire requirement alone.
NIBE F1255
Chapter 3 | F1255 – at your service
68