Nibe ESV 20 Installation Instructions Manual Download Page 24

ESV 20

VVM 240

22

DE

95 

 

FIGHTER 2010 

VVM 240 

AV 

AV 

S

ÄK 

S

RC 

TV 

FG 

RG 

UG 

FG2

RG2

VBP2 

S

V-V2

LEK

Rückl

au

f

Wärmep

u

mpe

AV

Sperrventil

FG

Vorl

au

ffühler

FG2

Vorl

au

ffühler 2

RG

Rückl

au

ffühler

RG2

Rückl

au

ffühler 2

SF

Schm

u

tzfilter

SV-V2 Mi

s

chventil 2

SÄV

Sicherheit

s

ventil

UG

A

u

ßenl

u

fttemper

a

t

u

rfühler

VBP2 Umwälzp

u

mpe 2

Vorl

au

f

Die Mont

a

ge ge

s

chieht wie folgt:

Sollte der Heizke

ss

el/Heiz

s

y

s

tem

b

ereit

s

 mit

W

ass

er gefüllt 

s

ein, m

uss

 die

s

e

s

 er

s

ab

gel

ass

en

werden.

Die externe Umwälzp

u

mpe (VBP2) 

s

owie d

as

Mi

s

chventil (SV-V2) 

a

n geeignetem Pl

a

tz 

au

ßer-

h

a

l

b

 de

s

 VVM 240 pl

a

tzieren. D

as

 Mi

s

chventil (SV-

V2) hinter dem VVM 240 im Vorl

au

f vor dem er

s

ten

Heizr

a

di

a

tor de

s

 Heiz

s

y

s

tem

s

 1 ein

bau

en. Die

Rückl

au

fleit

u

ng vom Heiz

s

y

s

tem 2 wird 

a

n

s

Mi

s

chventil (SV-V2) 

s

owie 

a

n die Rückl

au

fleit

u

ng

de

s

 Heiz

s

y

s

tem

s

 1 

a

nge

s

chlo

ss

en. Siehe

A

bb

ild

u

ng.

Die zwei mitgelieferten Temper

a

t

u

rfühler werden

gemäß A

bb

ild

u

ng 

a

m Heiz

s

y

s

tem 2 montiert.

D

ab

ei wird der Vorl

au

ffühler (FG2) 

au

f der Leit

u

ng

zwi

s

chen Umwälzp

u

mpe (VBP2) 

u

nd Heiz

s

y

s

tem

2 montiert. Der Fühler (RG2) i

s

au

f der

Rückl

au

fleit

u

ng de

s

 Heiz

s

y

s

tem

s

 2 z

u

 montieren.

Um eine korrekte Temper

a

t

u

rme

ssu

ng gewähren

z

u

 können, mü

ss

en Kont

a

ktp

as

te 

s

owie I

s

olier

u

ng

u

m die Fühler 

s

owie die Rohrleit

u

ng

ss

tellen ver-

wendet werden. Acht

u

ng! Eine verkehrt 

aus

geführ-

te In

s

t

a

ll

a

tion k

a

nn die ge

sa

mte F

u

nktion gefähr-

den.

Rohranschluss

Summary of Contents for ESV 20

Page 1: ...STALLATION INSTRUCTIONS ESV 20 EXTRA SHUNT FOR FIGHTER 360P FIGHTER 1120 FIGHTER 1220 VVM 240 MONTAGEANWEISUNG ESV 20 EXTRA MISCHVENTIL IM FIGHTER 360P FIGHTER 1120 FIGHTER 1220 VVM 240 LEK LEK GRUNDF...

Page 2: ......

Page 3: ...mesystem 2 avser det v rmesystem som arbetar med l gre temperatur Vattenfl det i de tv v rmesystemen tillsammans b r ej verstiga 1700 l h Sifferbeteckningar i f ljande text refererar till avsnittet Ko...

Page 4: ...plas till shuntventilen samt till returledningen fr n v rme system 1 se bild De tv medf ljande temperaturgivarna monteras i anslutning till v rmesystem 2 enligt bild Framledningsgivaren FG2 monteras p...

Page 5: ...t jordstift p kopplings plinten till v nster om kompressorkondensatorn Den andra nden p 5 ledarkabeln shuntmotorn och v rmeb rarpumpen kopplas in i kopplingsdosan enligt nedanst ende bild Kopplingsdos...

Page 6: ...plats utanf r VVM 240 Shuntventilen SV V2 placeras p framledningen efter VVM 240 f re f rsta radiatorn p v rmesystem 1 Returledningen fr n v rmesystem 2 kopplas till shuntventilen samt till returledni...

Page 7: ...sluts till position 7 och 8 p effektvaktskortets 2 nedre plint Returgivare 2 kopplas in till position 5 och 6 p samma kort Anv nd medf ljande rundstiftshylsor f r skarvning mellan tv ledaren och givar...

Page 8: ...st pannvattenk rlet v rmesystemet om detta r vattenfyllt Den extra v rmeb rarpumpen VBP2 placeras p l mplig plats utanf r FIGHTER 1130 1230 Shuntventilen SV V2 placeras p framledningen efter v rmepump...

Page 9: ...uts till position 7 och 8 p effektvaktskortets 2 nedre plint Returgivare 2 kopplas in till position 5 och 6 p samma kort Anv nd medf ljande rundstiftshylsor f r skarvning mellan tv ledaren och givaren...

Page 10: ...is EKXX eller LiYY enligt f ljande Den givare som anv nds som framledningsgivare 2 ansluts till position 7 och 8 p effektvaktskortets 2 nedre plint Returgivare 2 kopplas in till position 5 och 6 p sam...

Page 11: ...827 2 1 bar 3 0 4 VARNING DATASKY LT 123456 SERIENR 123456 VV KV L E K Art nr 611 2 1 bar 3 0 4 FIGHTER 360P FIGHTER 1130 VVM 240 FIGHTER 1230 Plats f r medf l jande rel kort Jordstift Plats f r medf...

Page 12: ...system 2 refers to the heating system that works at the lowest temperature The combined water flow in the two heating systems should not exceed 1700 l h The number designations in brackets in the fol...

Page 13: ...s well as the return pipe from heating system 1 see figure The two supplied temperature sensors are fitted in connection to heating system 2 as illustrated in the figure The flow sensor FS2 is fitted...

Page 14: ...he connection box as shown in the figure below The connection box can be mounted on a wall The sensors are connected with a two wire cable for example EKXX or LiYY as follows The sensor used as the fl...

Page 15: ...s positioned on the flow pipe after VVM 240 before the first radiator on heating sys tem 1 The return pipe from heating system 2 is connected to the shunt valve as well as the return pipe from heating...

Page 16: ...to positions 5 and 6 on the same card Use the supplied round pin adapters for the splice between the two wire cable and the sensor Electrical connection NOTE All electrical connections should be made...

Page 17: ...s positioned on the flow pipe after the heat pump before the first radiator on heating system 1 The return pipe from heating system 2 is connected to the shunt valve as well as the return pipe from he...

Page 18: ...ed to positions 5 and 6 on the same card Use the supplied round pin adapters for the splice between the two wire cable and the sensor Electrical connection 4 X4 1 X6 1 Return sensor 2 Flow sensor 2 2...

Page 19: ...ions 7 and 8 on the load monitor card 2 lower terminal Return sensor 2 is connected to positions 5 and 6 on the same card Use the supplied round pin adapters for the splice between the two wire cable...

Page 20: ...1 bar 3 0 4 VARNING DATASKY LT 123456 SERIENR 123456 VV KV L E K Art nr 611 2 1 bar 3 0 4 FIGHTER 360P FIGHTER 1120 VVM 240 FIGHTER 1220 Space for the supplied relay card Earth pin Space for the sup p...

Page 21: ...ssen wird Unter Heizsystem 2 ist dann jener Heizkreis zu verste hen der mit niedriger Temperatur arbeitet Der gemeinsame Heizwasserfluss f r beide Systeme sollte keine 1700 l h berschreiten Die Beziff...

Page 22: ...V V2 sowie an die R cklaufleitung des Heizsystems 1 angeschlossen Siehe Abbildung Die zwei mitgelieferten Temperaturf hler werden gem Abbildung am Heizsystem 2 montiert Dabei wird der Vorlauff hler FG...

Page 23: ...n Der Vorlauff hler FG2 ist auf der unteren Klemmleiste in Position 7 und 8 w hrend der R cklauff hler RG2 in Position 5 und 6 auf der Steuerelektronik 2 anzuschlie en Zur guten Verbindung zwischen de...

Page 24: ...n Das Mischventil SV V2 hinter dem VVM 240 im Vorlauf vor dem ersten Heizradiator des Heizsystems 1 einbauen Die R cklaufleitung vom Heizsystem 2 wird ans Mischventil SV V2 sowie an die R cklaufleitun...

Page 25: ...n Klemmleiste in Position 7 und 8 w hrend der R cklauff hler RG2 in Position 5 und 6 auf der Steuerelektronik 2 anzuschlie en ist Zur guten Verbindung zwischen dem 2 poligen Leiter sowie dem F hler si...

Page 26: ...Das Mischventil SV V2 hinter der W rmepumpe im Vorlauf vor dem ersten Heizradiator des Heizsystems 1 einbauen Die R cklaufleitung vom Heizsystem 2 wird ans Mischventil SV V2 sowie an die R cklaufleit...

Page 27: ...Klemmleiste in Position 7 und 8 w hrend der R cklauff hler RG2 in Position 5 und 6 auf der Steuerelektronik 2 anzuschlie en ist Zwecks guter Verbindung zwischen dem 2 poligen Leiter sowie dem F hler s...

Page 28: ...it 2 poligem Leiter z B EKXX oder LiYY wie folgt anzuschlie en Der Vorlauff hler FG2 ist auf der unteren Klemmleiste in Position 7 und 8 w hrend der R cklauff hler RG2 in Position 5 und 6 auf der Steu...

Page 29: ...ar 3 0 4 VARNING DATASKY LT 123456 SERIENR 123456 VV KV L E K Art nr 611 2 1 bar 3 0 4 FIGHTER 360P FIGHTER 1120 VVM 240 FIGHTER 1220 Platz f r mitgelieferte Relaiskarte Erdungsstift Platz f r mitgeli...

Page 30: ...ESV 20 28...

Page 31: ......

Page 32: ...H Am Reiherpfahl 3 29223 Celle Tel 05141 7546 0 Fax 05141 7546 99 E mail info nibe de www nibe de NIBE Energietechniek B V Postbus 2 4797 ZG WILLEMSTAD NB Tel 0168 477722 Fax 0168 476998 E mail info n...

Reviews: