Assembly
ERS S40 can be installed on a wall or placed on a hori-
zontal surface. For wall installation, place the enclosed
rail on a solid wall. Noise from the fans might be trans-
ferred to the rail. When placing on a horizontal surface,
fit the enclosed feet on the underside of ERS S40. It is
important for the surface where ERS S40 is placed to
be stable and to withstand the weight of the unit.
• Install with its back to an outside wall, ideally in a room
where noise does not matter, in order to eliminate
noise problems. If this is not possible, avoid placing
it against a wall behind a bedroom or other room
where noise may be a problem.
• Wherever the unit is located, walls to sound sensitive
rooms should be fitted with sound insulation.
• The HRV unit’s installation area always has to have a
temperature of at least -38 °C and max. 50 °C.
INSTALLATION AREA
Leave a free space of 800 mm in front of the product.
800
NOTE
Ensure that there is sufficient space (300 mm)
above the HRV unit for installing ventilation
hoses.
Mounting
When hanging on a wooden wall, a vibration damper is
recommended to prevent vibration being transferred.
1.
Install the enclosed bracket to the wall.
2.
Install ERS S40 on the brackets.
3.
Screw ERS S40 firmly into place on the bracket.
11
Chapter 2 | Delivery and handling
NIBE ERS S40-350
Summary of Contents for ERS S40-350
Page 1: ...IHB EN 2143 3 531854 INSTALLER MANUAL HRV unit NIBE ERS S40 350 UN...
Page 2: ......