General
This accessory is used to measure the amount of energy
produced by and supplied by the heating installation for
hot water and heating in the building.
The function of the energy meter is to measure flow and
temperature difference in the charge circuit. The value
is shown on F1345/F1355/VVM 500/SMO 40's display.
Compatible products
The accessory is suitable to following products from NIBE:
■
VVM 500
■
F1345
■
F1355
■
SMO 40
Contents
Flow meter
1 x
Cable to flow meter
1 x
Union nut
2 x
Copper pipe with pump flange (Ø 28)
2 x
Pipe connections
Install as follows:
The temperature is measured using the installation's
existing sensor.
VVM 500/SMO 40
The flow meter is installed in the charge circuit, for ex-
ample between the heat pump and first reversing valve.
F1345/F1355
The flow meter is installed in the charge circuit on the
heating medium side, between the heat pump and first
reversing valve.