EU Declaration of Conformity

Manufacturer

NIBE AB / Contura

Address

Box 134, Skulptörvägen 10
285 23 Markaryd, Sweden

E-Mail

[email protected]

Website

www.contura.eu

Telephone

+46 433 275100

THIS DECLARATION OF CONFORMITY IS ISSUED UNDER OUR SOLE RESPONSIBILITY FOR THE FOLLOWING PRODUCT:

Trade name

Contura 210

Identification of product 

www.contura.eu

THE OBJECT OF THE DECLARATION DESCRIBED ABOVE IS IN CONFORMITY WITH -
THE RELEVANT UNION HARMONIZATION LEGISLATION:

THE RELEVANT HARMONIZED STANDARDS:

DIR 2009/125/EC

EN 13240:2001/A2:2004/AC:2007

REG (EU) 2015/1185

CEN/TS 15883:2010

REG (EU) 2015/1186
REG (EU) 2017/1369
REG (EU) 305/2011

TECHNICAL DOCUMENTATION

Indirect heating functionality: 

No

Direct heat output:

5,0 kW

Energy Efficiency Index (EEI):

106,4

Test report

KIWA UK 61354, NB 0692

CHARACTERISTICS WHEN OPERATING WITH THE PREFERRED FUEL
ITEM

SYMBOL

VALUE

UNIT

ITEM

SYMBOL

VALUE

UNIT

HEAT OUTPUT

USEFUL EFFICIENCY, BASED ON NET CALORIFIC VALUE (NCV )

Nominal heat output:

P

nom

5,0

kW

Useful efficiency at nominal 
heat output

η  

th,nom

80,3

%

AUXILIARY ELECTRICITY CONSUMPTION

TYPE OF HEAT OUTPUT/ROOM TEMPERATURE CONTROL

At nominal heat output

el

max

-

kW

Single stage heat output, no room temperature control

Yes

At minimum heat output

el

min

-

kW

Two or more manual stages, no room temperature control

No

In standby mode

el

SB

-

kW

With mechanic thermostat room temperature control

No

With electronic room temperature control

No

With electronic room temperature control plus day timer

No

With electronic room temperature control plus week timer

No

OTHER CONTROL OPTIONS

Room temperature control, with presence detection

No

Room temperature control, with open window detection

No

With distance control option

Specific precautions for assembly, 
installation, or maintenance.

Fire protection and safety distances to combustible building materials must be observed under all circumstances.
A sufficient supply of combustion air must always be guaranteed. Air suction systems can interfere with the combustion 
air supply.

FUEL

PREFERRED 

FUEL  

OTHER SUITABLE 

FUEL

η

S

   (%)

EMISSIONS AT NOMINAL HEAT OUTPUT

PM

OGC

CO

NO

x

mg/ Nm

3

 (13% O

2

)

Wood logs with moisture content ≤25%

Yes

No

70,3

<40

<120

<1500

<200

Compressed wood with moisture content <12%

No

Yes

70,3

<40

<120

<1500

<200

Other woody biomass

No

No

Non-wood biomass

No

No

Anthracite and dry steam coal

No

No

Hard coke

No

No

Low temperature coke

No

No

Bituminous coal

No

No

Lignite briquettes

No

No

Peat briquettes

No

No

Blended fossil fuel briquettes

No

No

Other fossil fuel

No

No

Blended biomass and fossil fuel briquettes

No

No

Other blend of biomass and solid fuel

No

No

The undersigned is responsible for the manufacture and conformity with the declared performance.

Niklas Gunnarsson,

 Business area manager NIBE STOVES

Markaryd, April 1, 2022

GB

6

Summary of Contents for Contura C210

Page 1: ...C210 C210G contura eu ...

Page 2: ...laration 9 EU försäkran om överrenskommelse 10 Montering 15 Facts 3 Installation distances 4 Declaration of performance 5 EU Declaration of Conformity 6 Assembly 15 Fakta 11 Installasjonsavstand 12 Ytelseserklæring 13 EU samsvarserklæring 14 Montering 15 ...

Page 3: ...of the strong heat radiated through the hatch glass Placing flammable material closer than the safe distance indicated may cause a fire Pyre lighting can cause quick gas ignition with the risk of damage to property and personal injury Connection to chimney The stove must be connected to chimneys dimensioned for a minimum flue gas temperature of 400 C The stove should not be installed in a chimney ...

Page 4: ...on of painted non flammable walls we recommend that the same side distance as to combustible walls is used Example of an approved firewall is 120 mm solid brick or 100 mm aerated concrete INSTALLATION AGAINST COMBUSTIBLE WALLS INSTALLATION AGAINST FIREWALLS C210 170 50 305 50 570 150 500 Fire retardant wall of brick or concrete Constructional Hearth 320 200 250 400 150 150 500 Combustible wall Con...

Page 5: ...e classification A1 Minimum distance to flammable materials Rear 200 mm Side 250 mm Ceiling 1200 mm Front 1400 mm Floor 0 250 mm Corner 100 mm Fire hazard due to burning fuel falling out Pass EN 13240 2001 A2 2004 AC 2007 Cleanability Pass Emissions from combustion CO 1500 mg Nm3 13 O2 Surface temperatures Pass Temperature on the handle Pass Mechanical resistance Pass Temperature in the space for ...

Page 6: ...control No In standby mode elSB kW With mechanic thermostat room temperature control No With electronic room temperature control No With electronic room temperature control plus day timer No With electronic room temperature control plus week timer No OTHER CONTROL OPTIONS Room temperature control with presence detection No Room temperature control with open window detection No With distance contro...

Page 7: ...løse deler demonteres Demontering av ildstedsbekledning er beskrevet til slutt i denne veiledningen 1 Brennplater og hvelv Vermikulitt 2 Typeskilt 3 Kubbestopper 4 Rist 5 Innvendig bunnplate 6 Varmluftsgitter 7 Serienummer Prior to installation If the stove needs to be laid down for it to be moved loose components should be removed A description of how to remove hearth cladding can be found at the...

Page 8: ...16 10 10 VA NA DIU M No 7 CHROME 1 2 LEK 10 10 VA NA DI UM No 7 CHRO M E ...

Page 9: ...17 Ø ca 180 mm 2 1 4 3 SE NO GB Bakåtanslutning till murad skorsten Bakmontering til murt skorstein Rear connection to a masonry chimney ...

Page 10: ...18 HK HK 1 2 SE GB NO Tilluft Tillbehör Supply Accessory Tilluft Tilbehør ...

Page 11: ...19 1 3 2 ...

Page 12: ...20 4 3 1 2 SE GB NO Demontera eldstadsbeklädnaden Vermiculit How to remove the hearth surround Vermiculite Slik demonterer du ildstedsbekledningen Vermikulitt Handle with care ...

Page 13: ...21 7 5 6 ...

Page 14: ...rmanent stop to prevent closure of the air control unit beyond 31 open position Note When refuling open the air control fully for 3 5 minutes before closing down to the minimum air setting Mandatory for smoke control areas The permanent stop must be installed if the appliance is to be used in a smoke control area this stop must not be removed in smoke control areas otherwise an offence will be com...

Page 15: ...23 1 2 SE GB NO Placering på vedfack Tillbehör Positioning the log box Accessory Plassering av vedrom Tilbehør ...

Page 16: ...24 4 5 3 ...

Page 17: ...25 6 7 8 ...

Page 18: ...26 1 3 2 SE GB NO Montering av nedre lucka Tillbehör Installing the bottom door Accessory Montering av dør til nedre del Tilbehør ...

Page 19: ......

Page 20: ...811482 IAV SE EX C210 2 2022 08 31 NIBE AB Box 134 285 23 Markaryd Sweden contura eu ...

Reviews: