74
NIBE BA-SVM 10-200
Energy label
Section 13 |
Technical data
Model
AMS10-6 + BA-SVM 10-200/6 E / E EM / R
Type of heat pump
Air-water
Exhaust-water
Brine-water
Water-water
Low-temperature heat pump
Yes
No
Integrated immersion heater for additional heat
Yes
No
Heat pump combination heater
Yes
No
Climate
Average
Cold
Warm
Temperature application
Average (55
°
C)
Low (35
°
C)
Applied standards
EN14825 / EN16147, EN14511 and EN12102
Rated heat output
Prated
5.3
kW
Seasonal space heating energy efficiency
η
S
131
%
Declared capacity for space heating at part load and at outdoor temperature
Tj
Declared coefficient of performance for space heating at part load and at
outdoor temperature Tj
Tj=-7°C
Pdh
4.7
kW
Tj=-7°C
Pdh
1.88
-
Tj=+2°C
Pdh
2.8
kW
Tj=+2°C
Pdh
3.26
-
Tj=+7°C
Pdh
1.8
kW
Tj=+7°C
Pdh
4.72
-
Tj=+12°C
Pdh
2.7
kW
Tj=+12°C
Pdh
6.47
-
Tj=biv
Pdh
4.7
kW
Tj=biv
Pdh
1.88
-
Tj=TOL
Pdh
4.1
kW
Tj=TOL
Pdh
1.77
-
Tj=-15°C(ifTOL<-20°C)
Pdh
kW
Tj=-15°C(ifTOL<-20°C)
Pdh
-
Bivalent temperature
T
biv
-7
°C
Min. outdoor air temperature
TOL
-10
°C
Cycling interval capacity
Pcych
kW
Cycling interval efficiency
COPcyc
-
Degradation coefficient
Cdh
0.99
-
Max supply temperature
WTOL
58
°C
Power consumption in modes other than active mode
Additional heat
Off mode
P
OFF
0.007
kW
Rated heat output
Psup
1.2
kW
Thermostat-off mode
P
TO
0.012
kW
Standby mode
P
SB
0.012
kW
Type of energy input
Electric
Crankcase heater mode
P
CK
0
kW
Other items
Capacity control
Variable
Rated airflow (air-water)
2 526
m
3
/h
Sound power level, indoors/outdoors
L
WA
35 / 51
dB
Rated heating medium flow
m
3
/h
Annual energy consumption
Q
HE
3 248
kWh
Brine flow rate in brine-water or water-water
heat pumps
m
3