55
NIBE BA-SVM 10-200
The SERVICE menu has orange text and is intended
for the advanced user. This menu has several sub-
menus. Status information for the relevant menu can
be found on the display to the right of the menus.
• Operating settings
Operating settings for the
control module.
• System settings
System settings for the control
module, activating accessories etc.
• Accessory settings
Operational settings for dif-
ferent accessories.
• Prog. input/output
Software-controlled setting of
inputs and outputs on the input card (AA3) and
terminal block (x2).
• Factory setting service
Total reset of all settings
(including settings available to the user) to default
values.
• Forced control
Forced control of the various com-
ponents of the indoor unit.
• Start guide
Manual launch of the start guide
which is run the first time the control module is
started.
• Quick start
Quick start of the compressor.
Service submenus
Go to the main menu and press down on the Back but-
ton for 7 seconds to access the Service menu.
CAUTION
Incorrect settings in the service menus can damage the
system, the heat pump and the indoor unit.
Menu 5.1 - Operating settings
Menu 5.1.1 - Hot water settings
Operating settings for the control module can be set
in the submenus.
Operating settings for the control module can be set
in the submenus.
economy
Start temp. setting range in econ. mode: 5 – 55 °C
Start temp. factory setting in econ. mode: 39°C
Stop temp. setting range in econ. mode: 5 – 60°C
Stop temp. factory setting in econ. mode: 43°C
normal
Start temp. setting range in normal mode: 5 – 60°C
Start temp. factory setting in normal mode: 42°C
Stop temp. setting range in normal mode: 5 – 65°C
Stop temp. factory setting in normal mode: 46°C
luxury
Start temp. setting range in lux. mode: 5 – 65°C
Start temp. factory setting in lux. mode: 45°C
Stop temp. setting range in lux. mode: 5 – 65°C
Stop temp. factory setting in lux. mode: 49°C
Menu 5.1.2 - Max. supply temperature
Menu 5.1.3 - Max. diff. supply temp.
Here you set the start and stop temperature of the hot
water for the different temperature options in menu 2.2
as well as the stop temperature for periodic increase in
menu 2.9.1.
Set the maximum supply temperature for the climate
system here. If the installation has more than one
climate system, individual maximum supply temper-
atures can be set for each system. Climate systems 2
- 8 cannot be set to a higher max. supply temperature
than climate system 1.
Here you set the maximum permitted difference be-
tween the calculated and actual supply temperature dur-
ing compressor heating or additional heat mode. Max.
diff. additional heat can never exceed max. diff. compres-
sor.
climate system
Setting range: 5-65°C
Factory setting: 55°C
max. diff. compressor
Setting range: 1 – 25°C
Factory setting: 10°C
max. diff. add. heat
Setting range: 1 – 24°C
Factory setting: 7°C
NOTE
In underfloor heating systems, the max. supply tem-
perature is set between 35 and 45 °C.
For information on the maximum permitted underfloor
heating supply temperature, ask your floor and heating
system supplier/contractor.
stop. temp. periodic increase
Setting range: 55 – 65°C
Factory setting: 60°C
step difference compressors
Setting range:0,5 – 4,0°C
Factory setting: 1,0°C
charge method
Setting range: target temp., delta temp.
Factory setting: delta temp.
Section 9 |
Control