background image

16

NIBE

TM

 AP-WH7 

 

We reserve the right to make technical changes GB830174Ni/210621 

– 

Translation of the operating manu-

Hydraulic diagram legend

1)

Heat pump

2)

8QGHUÀRRUKHDWLQJUDGLDWRUV

3)

Vibration decoupler

4)

Sylomer strips for under unit

5)

Shut-off with emptying

6)

Expansion vessel scope of supply

7)

Safety valve

8)

Shut-off 

9)

Heating circulating pump (HUP)

10)

Check valve

11)

Single room regulator

12)

2YHUÀRZYDOYH

13)

Steam-proof insulation

14)

Domestic hot water circulating pump (BUP)

15)

Mixing circuit three-way mixer (discharge)

16)

Expansion vessel, provided on site

17)

Temperature difference regulator (SLP)

18)

Heating element, heating (ZWE)

19)

Mixing circuit four-way mixer (charge)

20)

Heating element, domestic hot water (ZWE)

21)

Mixing circuit circulating pump (FP 1-3)

22)

Swimming pool circulating pump (SUP)

23)

Booster circulating pump (ZUP)  
(reconnect circulating pump integrated  
in the heat pump)

24)

Pressure gauge

25)

H domestic hot water circulating 
pump (HUP)

26)

Domestic hot water switching valve (BUP)  
(B = open (break contact) when off circuit)

27)

Heating element, heating and domestic hot 
water (ZWE)

28)

Brine circulating pump (VBO)

29)

Dirt trap, 1 mm screen size

30)

Collecting tank for brine mixture

31)

Wall penetration

32)

Supply pipe

33)

Brine distributor

34)

Ground collector

35)

Ground probe

36)

Groundwater well pump

37)

Thermostat 0°C - 16°C

38)

Flow switch

39)

Suction well

40)

Recharging well

41)

Heating circuit tap

42)

Circulating pump (ZIP)

43)

Brine/water heat exchanger (cooling function)

44)

Three-way mixing valve (cooling function)

45)

Cap valve

46)

Filling and emptying valve

47)

Swimming pool switching valve (SUP)  
(B = open (break contact) when off circuit)

48)

Domestic hot water charge pump (BLP)

49)

*URXQGZDWHUÀRZGLUHFWLRQ

50)

Buffer storage tank

51)

Separating tank

52)

*DVRURLO¿UHGERLOHU

53)

:RRG¿UHGERLOHU

54)

Domestic hot water tank

55)

Brine pressure detector

56)

Swimming pool heat exchanger

57)

Geothermal heat exchanger

58)

Ventilation in the house

59)

Plate heat exchanger

60)

Cooling mode switching valve 
(B = open (break contact) when off circuit)

61)

Cooling tank

62)

Optional heat meter

63)

Solar circuit switching valve 
(B = open (break contact) when off circuit)

64)

Cooling circulating pump

65)

Compact distributor

66)

Fan convectors

67)

Solar domestic hot water tank

68)

Solar separating tank

69)

Multifunctional tank

70)

Solar separating unit

101)

Control provided on site

102)

Dew point monitor, optional accessory

103)

Room thermostat for reference room included 
scope of delivery

104)

Heat pump scope of delivery

105)

Cooling circuit module box can be removed 
for installation

106)

6SHFL¿FJO\FROPL[WXUH

107)

Scalding protection / thermostatic mixing 
valve

108)

Solar pump group

109)

2YHUÀRZYDOYHPXVWEHFORVHG

110)

Hydraulic tower scope of delivery

111)

Mound for additional heating element

TA / A

= Outdoor sensor

TBW / B = Domestic hot water sensor

TB1 - 3 / C = Flow sensor, mixing circuit 1-3

D

 8QGHUÀRRUWHPSHUDWXUHOLPLWHU

TSS / E =  Sensor, temperature difference regulator 

(Low temperature)

TSK / E =  Sensor, temperature difference regulator 

(high temperature)

TEE / F = Sensor, external energy source

TRL / G = Sensor, external return

STA

= Branch regulating valve

Important notice! 
These hydraulic diagrams are schematic 
representations and are only provided as an aid! 
They do not release you from the need to carry out 
your own planning!
Shut-off and bleeding devices, and safety-related 
measures are not completely shown in them! 

7KH\PXVWEHLQVWDOOHGIRUWKHVSHFL¿FV\VWHPLQ

accordance with relevant standards and regulations. 
The pipes must be dimensioned according to the 

QRUPDOYROXPHWULFÀRZUDWHRIWKHKHDWSXPSRUWKH

free pressure of the integrated circulating pump!

DE100801

Summary of Contents for AP-WH7

Page 1: ...We reserve the right to make technical changes GB830174Ni 210621 Translation of the operating manual Operating Manual GB MULTI FUNCTIONAL DOMESTIC HOT WATER TANK Accessories for heat pumps NIBE AP WH7...

Page 2: ...manual was written for several different models of the unit always comply with the parameters for the respective model This operating manual is intended only for persons assigned to work on or operat...

Page 3: ...MAINTENANCE OF THE UNIT 5 INSTRUCTIONS FOR QUALIFIED TECHNICIANS SCOPE OF DELIVERY 5 INSTALLATION AND ASSEMBLY 6 Transport to installation location 6 Installation 7 Circulation kit installation 8 Ins...

Page 4: ...expires if work is carried out on the unit and its components contrary to the instructions in this operating manual if work is improperly carried out on the unit and its components if work is carried...

Page 5: ...ck the safety valve provided by customer for the hot water tank at regular intervals It is a good idea to have a maintenance contract with a heating installation company The company will carry out the...

Page 6: ...ou can also transport the unit using a hand truck WARNING Several people are required to transport the unit Do not underestimate the weight of the tank Technical data weight overview CAUTION Wear safe...

Page 7: ...rt Always secure the tank on the hand truck with a ratchet strap INSTALLATION NOTICE Ensure that the foam insulation is still in the bottom of the storage tank WARNING The storage tank must always be...

Page 8: ...rage tank so that the punched out holes fit over the sockets Then close the zip CAUTION The zip must be closed by two people to relieve the strain Replace the tank cover and push the grommets over the...

Page 9: ...rrugated pipe Use the union nut to screw together the flexible corrugated pipe and the elbow CAUTION Tighten the union nut carefully to prevent damage to the seal INSULATE THE CIRCULATION CONNECTION N...

Page 10: ...eating network Note and follow the relevant DVGW regulations and recommendations and the regulations of the water supply company when connecting to the drinking water Integrate the multi functional st...

Page 11: ...rating pressure bar 10 10 10 Test pressure bar 15 15 15 Max operating temperature C 95 95 95 Domestic hot water heat exchanger Exchanger area m 7 5 8 7 10 9 Exchanger volume l 40 46 56 Max operating p...

Page 12: ...1 AG 4 Sensor pocket domestic hot water sensor 13x75 5 Sensor pocket 13x75 6 Heating element hot water max 9kW 1 1 2 IG 7 Domestic hot water return heat pump 1 1 4 IG 8 Circulation top connection kit...

Page 13: ...estic hot water withdrawal 1 AG 4 Sensor pocket domestic hot water sensor 13x100 5 Sensor pocket 13x100 6 Heating element hot water max 9kW 1 1 2 IG 7 Domestic hot water return heat pump 1 1 4 IG 8 Ci...

Page 14: ...stic hot water withdrawal 1 AG 4 Sensor pocket domestic hot water sensor 13x100 5 Sensor pocket 13x100 6 Heating element hot water max 9kW 1 1 2 IG 7 Domestic hot water return heat pump 1 1 4 IG 8 Cir...

Page 15: ...he operating manual NIBETM AP WH7 Installation plan for all storage tanks 1000 800 MF C 1 Legend GB819397 All dimensions in mm We reserve the right to modify technical specifications without prior not...

Page 16: ...r storage tank 51 Separating tank 52 DV RU RLO UHG ERLOHU 53 RRG UHG ERLOHU 54 Domestic hot water tank 55 Brine pressure detector 56 Swimming pool heat exchanger 57 Geothermal heat exchanger 58 Ventil...

Page 17: ...17 al We reserve the right to make technical changes GB830174Ni 210621 Translation of the operating manual NIBETM AP WH7 Hydraulic connection 1 83 83 RGH 67 83 3 0 7 PD 7 75 7 0 7 PD P 76 766 6 3 3...

Page 18: ...18 NIBETM AP WH7 We reserve the right to make technical changes GB830174Ni 210621 Translation of the operating manu Hydraulic connection 2 83 83 8 RGH 67 83 3 0 7 PD 7 75 7 0 7 PD P 76 766 6 3 3...

Page 19: ...19 al We reserve the right to make technical changes GB830174Ni 210621 Translation of the operating manual NIBETM AP WH7...

Page 20: ...3 Fax 97 17 29 33 E mail info volundvt dk www volundvt dk NIBE Systemtechnik GmbH Am Reiherpfahl 3 29223 Celle Tel 05141 7546 0 Fax 05141 7546 99 E mail info nibe de www nibe de CH NIBE W rmetechnik A...

Reviews: