Nibe AHP S300 Installer Manual Download Page 27

Contact information

DENMARK

CZECH REPUBLIC

AUSTRIA

Vølund Varmeteknik A/S
Industrivej Nord 7B, 7400 Herning
Tel: +45 97 17 20 33
[email protected]

volundvt.dk

Družstevní závody Dražice - strojírna
s.r.o.
Dražice 69, 29471 Benátky n. Jiz.
Tel: +420 326 373 801
[email protected]

nibe.cz

KNV Energietechnik GmbH
Gahberggasse 11, 4861 Schörfling
Tel: +43 (0)7662 8963-0
[email protected]

knv.at

GERMANY

FRANCE

FINLAND

NIBE Systemtechnik GmbH
Am Reiherpfahl 3, 29223 Celle
Tel: +49 (0)5141 75 46 -0
[email protected]

nibe.de

NIBE Energy Systems France SAS
Zone industrielle RD 28
Rue du Pou du Ciel, 01600 Reyrieux
Tél: 04 74 00 92 92
[email protected]

nibe.fr

NIBE Energy Systems Oy
Juurakkotie 3, 01510 Vantaa
Tel: +358 (0)9 274 6970
[email protected]

nibe.fi

NORWAY

NETHERLANDS

GREAT BRITAIN

ABK AS
Brobekkveien 80, 0582 Oslo
Tel: (+47) 23 17 05 20
[email protected]

nibe.no

NIBE Energietechniek B.V.
Energieweg 31, 4906 CG Oosterhout
Tel: +31 (0)168 47 77 22
[email protected]

nibenl.nl

NIBE Energy Systems Ltd
3C Broom Business Park,
Bridge Way, S41 9QG Chesterfield
Tel: +44 (0)845 095 1200
[email protected]

nibe.co.uk

SWEDEN

RUSSIA

POLAND

NIBE Energy Systems
Box 14
Hannabadsvägen 5, 285 21 Markaryd
Tel: +46 (0)433-27 3000
[email protected]

nibe.se

EVAN
bld. 8, Yuliusa Fuchika str.
603024 Nizhny Novgorod
Tel: +7 831 419 57 06
[email protected]

nibe-evan.ru

NIBE-BIAWAR Sp. z o.o.
Al. Jana Pawla II 57, 15-703 Bialystok
Tel: +48 (0)85 66 28 490

biawar.com.pl

SWITZERLAND

NIBE Wärmetechnik c/o ait Schweiz
AG
Industriepark, CH-6246 Altishofen
Tel. +41 (0)58 252 21 00
[email protected]

nibe.ch

For countries not mentioned in this list, contact NIBE Sweden or check

nibe.eu

for more information.

Summary of Contents for AHP S300

Page 1: ...IHB EN 1911 1 531217 INSTALLER MANUAL Accumulator tank AHP S AHPS S AHPH S...

Page 2: ......

Page 3: ...m diagram 13 Dimensions and pipe connections 15 Installation alternative 17 5 Electrical installation 17 Sensors 18 6 Commissioning and adjusting 18 Filling and venting 19 7 Service 19 Service actions...

Page 4: ...olved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Rights to make any design or technical modifications are reserved NIBE...

Page 5: ...product s serial number when reporting a fault RECOVERY Leave the disposal of the packaging to the in staller who installed the product or to special waste stations Do not dispose of used products wit...

Page 6: ...must be carried out by a suitably qualified person Date Signature Notes Description Heat pump page 16 Shut off valves Expansion vessel Safety valve Hot water page 15 Shut off valves Mixing valve Safet...

Page 7: ...frost proof and equipped with a floor drain Position AHP S AHPS S AHPH S on a firm base that can take the weight preferably on a concrete floor or foundation Use the accumulator tank s adjustable feet...

Page 8: ...ds SIDE COVERS UN UN UN The side covers can be removed to facilitate the install ation 1 Remove the screws from the upper and lower edges 2 Twist the cover slightly outward 3 Move the hatch backwards...

Page 9: ...PS S300 LEK XL8 XL4 XL3 XL9 PZ3 XL3 XL4 XL8 XL8 XL13 XL14 XL45 XL46 XL9 XL45 UL UA2 UA1 PZ1 XL19 UL UA2 UA3 UA1 PZ1 XL19 QM1 BT6 9 Chapter 3 Accumulator tank design AHP S AHPS S AHPH S 3 Accumulator t...

Page 10: ...ernal heat source XL19 Docking connection level 1 XL45 Docking connection level 2 XL46 HVAC components Drain valve heating medium QM1 Submerged tube for hot water sensor BT7 display UA1 Submerged tube...

Page 11: ...the system must be equipped with a pressure expansion vessel pre pressurised to 0 5 bar Internal volume in AHP S AHPS S AHPH S for calculat ing expansion vessel is 270 l The expansion vessel s volume...

Page 12: ...at to heat a pool The heat between level 2 and the top of the tank is then intended to pre heat the hot water for the heat pump AHPH S300 AHPH S300 consists of an accumulator tank with integ rated tap...

Page 13: ...1 600 298 298 289 442 59 55 428 55 195 245 245 1800 600 78 561 600 298 298 289 442 59 5 55 XL45 XL13 XL9 XL46 XL14 XL4 XL3 XL8 XL19 QM1 Connection AHPS S300 ext G20 QM1Tapping valve 22 mm XL3Cold wate...

Page 14: ...Connection AHPH S300 22 mm XL3Cold water 22 mm XL4Hot water ext G25 XL8Docking connection supply line from heat pump ext G25 XL9Docking connection return line to heat pump ext G25 XL19Docking connect...

Page 15: ...ol Venting valve Shut off valve Mixing valve Circulation pump Expansion vessel Pressure gauge P Level vessel Control valve Particle filter Safety valve Temperature sensor Thermometer T Sun Heat pump R...

Page 16: ...is not suffi cient or to reduce heat spikes TO GROUND SOURCE HEAT PUMP EXTERNAL HEAT SOURCE AHPH S300 can be docked with another heat source for example NIBE F1145 1155 TO PELLET BOILER AHPS S300 and...

Page 17: ...tube for hot water sensor UA1 and UA2 AHPS S300 and AHPH S300 has sensor BT6 fitted in submerged tube UA2 at the factory AHPS S300 can also be supplemented with a solar sensor This is placed in the su...

Page 18: ...2 QM60 2 Fill the vessel in AHPS S300 through the drain valve QM1 3 When the water exiting the vent valve CP2 QM60 is not mixed with air the vessel is full 4 Close the vent valve CP2 QM60 5 AHP S300 f...

Page 19: ...cu mulator tank Contact your installer if you are unsure how one checks the valve EMPTYING AHP S300 and AHPH S300 The vessel is drained via docking connection XL19 AHPS S300 Empty the vessel via the d...

Page 20: ...TE To achieve the stop temperatures in the dia gram above the target temp charge method must be selected in the heat pump s control system PRESSURE DROP DIAGRAM SOLAR COIL AHPS S300 0 0 340 480 730 98...

Page 21: ...out coordinates AHP S300 600 561 600 442 1800 188 271 196 225 298 298 289 AHPS S300 1800 600 188 108 108 107 182 225 271 78 561 600 298 298 289 442 59 55 428 55 195 245 245 21 Chapter 8 Technical dat...

Page 22: ...AHPH S300 600 561 600 442 1800 188 275 193 243 229 185 55 428 78 59 55 298 298 289 AHP S AHPS S AHPH S Chapter 8 Technical data 22...

Page 23: ...me solar coil 1 0 10 MPa bar Max pressure in hot water coil Stainless steel Corrosion protection hot water coil Copper Corrosion protection solar coil Capacity hot water heating according to EN 255 3...

Page 24: ...e 15 To ground source heat pump 16 M Marking 4 Maximum boiler and radiator volumes 11 P Pipe and ventilation connections System diagram 12 Pipe connections 11 Cold and hot water 15 Dimensions and pipe...

Page 25: ......

Page 26: ......

Page 27: ...nibe fi NORWAY NETHERLANDS GREAT BRITAIN ABK AS Brobekkveien 80 0582 Oslo Tel 47 23 17 05 20 post abkklima no nibe no NIBE Energietechniek B V Energieweg 31 4906 CG Oosterhout Tel 31 0 168 47 77 22 i...

Page 28: ...y Systems All product illustrations facts and data are based on the available information at the time of the publication s approval NIBE Energy Systems makes reservations for any factual or printing e...