![NIBE-BIAWAR HK 200M Installation Manual Download Page 10](http://html.mh-extra.com/html/nibe-biawar/hk-200m/hk-200m_installation-manual_1686585010.webp)
10
HK 200M
P
P
HK 200 S
HK 200 M
P
The HK 200M indoor unit is equipped with a coil water
heater, diaphragm expansion vessel , safety group,
electric heater, isolation valves, plate heat exchang
-
er, metering instruments, and an electronic circulation
pump. Together with the heat pump NIBE Monoblok
and NIBE SMO module, it forms a complete heating
system.
The F2030, F2040 8 kW; F2040 12 kW, F2120 8
kW; F2120 12 kW, F2120 16 kW outdoor unit pro
-
vides heat for heating the domestic hot water and
supplying the heating system while using free ener-
gy in the outdoor air, efficiently operating within the
range of low temperatures up to -20°C.
The connection of the outdoor unit and indoor unit
HK 200M with a system of pipes filled with a cooling
medium secures the connection against freezing in
the event of any power outages. The control of sys-
tem operation is the function of SMO 20 or SMO 40
module.
Installation diagram
Chapter 4 |
Pipe connections
Symbol Meaning
Vent
Cut-off valve
Water tap
Non-return valve
Balancing valve
Three-way valve
Safety valve
Thermometer
Temperature sensor
Diaphragm expansion
vessel
T
P
T
P
T
P
T
P
T
P
T
P
T
P
T
P
T
P
T
P
Symbol Meaning
Manometer
Circulation pump
Particulate filter
T
P
Compressor
T
P
Heat exchanger
Cooling
Central heating system
Domestic hot water
Heating systems
Floor heating
T
P
T
P
T
P
T
P
T
P
T
P
Summary of Contents for HK 200M
Page 34: ...34 HK 200M Notes ...
Page 35: ......