background image

© 2015 National Instruments. All rights reserved. 

377006B-01

Nov15

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on National Instruments trademarks. Other 

product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National 
Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and third-party 

legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 

for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES 
NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR 
ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable 
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

Reverification

Repeat the 

Accuracy Verification

 section to determine the As-Left status of the device.

Note

If any test fails Reverification after performing an adjustment, verify that you 

have met the 

Test Conditions

 before returning your device to NI. Refer to 

World Wide 

Support and Services

 for assistance in returning the device to NI.

Specifications

Refer to the 

NI PXIe-4304/4305 Specifications 

document for detailed PXIe-4304/4305 

specification information.

World Wide Support and Services

The National Instruments website is your complete resource for technical support. At 

ni.com/

support

 you have access to everything from troubleshooting and application development 

self-help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and 

other services.

Visit 

ni.com/register

 to register your National Instruments product. Product registration 

facilitates technical support and ensures that you receive important information updates from NI. 

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 
Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For 
telephone support in the United States, create your service request at 

ni.com/support

 or dial 

1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the 
Worldwide Offices section of 

ni.com/niglobal

 to access the branch office websites, which 

provide up-to-date contact information, support phone numbers, email addresses, and current 
events.

Summary of Contents for PXIe-4304

Page 1: ... 10 Specifications 10 World Wide Support and Services 10 Software Calibrating the NI PXIe 4304 4305 requires the installation of NI DAQmx on the calibration system Driver support for calibrating the PXIe 4304 4305 was first available in NI DAQmx 15 1 1 For the list of devices supported by a specific release refer to the NI DAQmx Readme available on the version specific download page or installatio...

Page 2: ... reference information NI PXIe 4304 4305 Specifications PXIe 4304 4305 specifications and calibration interval NI DAQmx Readme Operating system and application software support in NI DAQmx NI DAQmx Help Information about creating applications that use the NI DAQmx driver LabVIEW Help LabVIEW programming concepts and reference information about NI DAQmx VIs and functions NI DAQmx C Reference Help R...

Page 3: ...able 1 Table 1 Recommended Equipment for PXIe 4304 4305 Verification and Adjustment Equipment Recommended Model Requirements DMM PXI 4071 Use a DMM that has an accuracy of 32 ppm or better when measuring voltages higher than 10 V and an accuracy of 2 1 μV or better when measuring 0 V PXI Express Chassis PXIe 1062Q If this chassis is unavailable use another PXI Express chassis such as the PXIe 1082...

Page 4: ...I PXIe 4304 4305 and TB 4304 User Guide and Terminal Block Specifications 2 Configure the PXIe 4139 to voltage output mode and enable remote sensing Connect the PXIe 4139 output to the TB 4304 as shown in Figure 2 Table 2 TB 4304 Analog Signal Names Signal Name Signal Description AI Positive input voltage terminal AI Negative input voltage terminal AIGND Analog ground input NI TB 4304 AI3 AI3 AI2 ...

Page 5: ...d pair wire to eliminate noise and thermal offsets Maintain an ambient temperature of 23 C 5 C The PXIe 4304 4305 temperature will be greater than the ambient temperature Maintain an internal device temperature range of Tcal 5 C for the PXI 4071 1 Keep relative humidity below 80 Allow a warm up time of at least 15 minutes to ensure that the PXIe 4304 4305 measurement circuitry is at a stable opera...

Page 6: ...the sequence of operations and provides the test points required to verify the PXIe 4304 4305 The verification procedures assume that adequate traceable uncertainties are available for the calibration references The PXIe 4304 4305 has 32 independent analog input channels You can verify the accuracy of any or all of the channels depending upon your desired test coverage Complete the following steps...

Page 7: ...ement Range 1 V range for test points of 0 V 100 V range for all other test points Digital Resolution 7 5 digits Aperture Time 100 ms Autozero On ADC Calibration On Input Impedance 10 MΩ DC Noise Rejection High Order Number of Averages 1 Power Line Frequency Dependent upon the local power line characteristics Table 5 AI Voltage Mode Setup Configuration Value Channel Name Dev1 aix where x refers to...

Page 8: ...B 4304 as shown in Figure 2 3 Call the DAQmx Initialize External Calibration function with the following parameters Device In Dev1 Password1 NI 4 Call the 4304 4305 instance of the DAQmx Setup SC Express Calibration function with the following parameters calhandle in calhandle output from DAQmx Initialize External Calibration rangeMax Appropriate Range Max starting with the first Test Point value ...

Page 9: ... for the remaining Test Point values from Table 7 for the corresponding range that was configured in step 4 10 Repeat steps 4 through 9 for the remaining ranges from Table 7 11 Call the 4304 4305 instance of the DAQmx Adjust SC Express Calibration function with the following parameters calhandle in calhandle output from DAQmx Initialize External Calibration action commit EEPROM Update When an adju...

Page 10: ...he As Left status of the device Note If any test fails Reverification after performing an adjustment verify that you have met the Test Conditions before returning your device to NI Refer to World Wide Support and Services for assistance in returning the device to NI Specifications Refer to the NI PXIe 4304 4305 Specifications document for detailed PXIe 4304 4305 specification information World Wid...

Reviews: