Table 2. Back Panel Connector Descriptions (Continued)

Connector

Description

 

 

GPS ANT

Input terminal for the GPS antenna signal. GPS ANT is an SMA (f)
connector with a maximum input power of -15 dBm and an output of
3.3 V DC to power an active antenna.

Notice

 

Do not terminate the GPS ANT port if you do not use

it.

REF IN

Input terminal for an external reference signal to synchronize the device.
REF IN is an SMA (f) connector with an impedance of 50 Ω, and it is a
single-ended reference input. REF IN accepts a 10 MHz signal with a
minimum input power of 0 dBm (0.632 V pk-pk) and a maximum input
power of 15 dBm (3.56 V pk-pk) for a square wave or sine wave.

PPS IN

Input terminal for PPS timing reference. PPS IN is an SMA (f) connector
with an impedance of 50 Ω and is a single-ended input channel. PPS IN
accepts 0 V to 3.3 V TTL and 0 V to 5 V TTL signals.

TRIG IN/OUT

Input/Output trigger terminal. This port can be used to output the PPS
timing reference. TRIG IN/OUT is an SMA (f) connector with an
impedance of 50 Ω and is a single-ended port. The output voltage is 0 V
to 3.3 V TTL. You can also use this port as a triggered output
(TRIG OUT) that you program in LabVIEW FPGA.

POWER

Input that accepts a 12 V ± 5%, 16 A external DC power connector.

CONSOLE JTAG A USB Type-C port that connects the host computer to the device FPGA

for development and debugging. This port provides access to the FPGA
JTAG, the PS serial console, and the SCU serial console. It should be
used with the 115200 baud, 8 data bits, 1 stop bit, no parity. LabVIEW
FPGA does not currently support configuring or programming the device
FPGA using the JTAG connector.

USB to PS

A USB Type-C 2.0 port that can be used to connect peripheral devices to
the processing system (PS), such as a USB mass storage device. May also
be used to complete functions such as writing a new file system to the
internal storage.

ETHERNET

1 Gigabit Ethernet Connection that interfaces with the onboard PS. Can
be used to connect to the PS through SSH. Can be used for UHD
management traffic in Network Mode. By default, the 1 Gb Ethernet
connection is configured to use a DHCP assigned IP address.

Ettus USRP X410 Getting Started Guide

  | 

© National Instruments Corporation

  | 

5

Summary of Contents for Ettus USRP X410

Page 1: ...ing the System Requirements 3 Ettus USRP X410 Front Panel Back Panel and LEDs 3 Selecting Your Driver 6 NI USRP 8 Setting Up the Device 8 Installing the Software 11 Programming the Device 11 UHD 16 Setting Up the Device 16 Installing the Software 18 Programming the Device 18 NI Services 19 Unpacking the Kit Notice To prevent electrostatic discharge ESD from damaging the device ground yourself usin...

Page 2: ... SENSITIVE ESD SENSITIVE 2 Channel RF 1 MHz to 7 2 GHz Transceiver 400 MHz BW 2 Channel RF 1 MHz to 7 2 GHz Transceiver 400 MHz BW 1 2 4 3 1 Ettus USRP X410 2 CAT 5E Ethernet Cable 3 USB A m to USB C m with Jack Screw Cable 4 Power Supply 5 Ettus USRP X410 Documentation Note 6 Ettus USRP X410 Safety Environmental and Regulatory Information Additional Items for Device Set Up Cables PCIe MXI express...

Page 3: ...stem and supported application development environments ADEs The NI USRP Readme is available online on the driver software download page or at ni com manuals The UHD Readme is available on The USRP Hardware Driver Repository Ettus USRP X410 Front Panel Back Panel and LEDs Figure 2 Front Panel TX RX 0 TX RX 0 TX OUTPUT MAX 15 dBm RX INPUT MAX 20 dBm ALL RF PORTS 50 Ω RX 1 RX 1 DB 1 DB 0 RF 0 RF 1 T...

Page 4: ...onnectors Output voltage can be configured per individual connector either 1 8 V default 2 5 V or 3 3 V Figure 3 Back Panel CONSOLE ETHERNET POWER USB to PS GPS ANT IN 15 dBm MAX OUT 3 3 V DC PPS IN 0 0 QSFP28 iPass zHD 1 1 3 3 V 3 V MIN 5 V MAX TRIG IN OUT 3 3 V 2 V MIN 5 V MAX REF IN 15 dBm MAX 10 100 1000 12 V DC 16A MAX RESET LED 1 LED 0 PWR LED 2 JTAG XXXXXXX XX AIRFLOW XXXXXXX EXHAUST Table ...

Page 5: ...e of 50 Ω and is a single ended port The output voltage is 0 V to 3 3 V TTL You can also use this port as a triggered output TRIG OUT that you program in LabVIEW FPGA POWER Input that accepts a 12 V 5 16 A external DC power connector CONSOLE JTAG A USB Type C port that connects the host computer to the device FPGA for development and debugging This port provides access to the FPGA JTAG the PS seri...

Page 6: ...is read or write activity on the eMMC Solid There is read or write activity on the eMMC PWR Indicates the power state of the device OFF The device is powered off Green Solid The device is powered on and the power is good Red Solid The device is in a power error state Amber Solid The device is powered off and the power is good Note The previous table describes default LED settings LED functionality...

Page 7: ...environment helps accelerate the design of wireless systems and makes FPGA programming accessible to those without HDL design expertise Using LabVIEW you have the option to program the FPGA and host in a single development environment Users have the option to customize the FPGA when using NI USRP UHD uses a common open source software interface that increases code portability allowing applications...

Page 8: ...ts required for your project to the front panel terminals of the Ettus USRP X410 Installing the Modules into the Chassis Install the PXIe 8881 or other PXI controller in the first slot of your chassis and then the PXIe 8394 or other PXI bus extension module in a slot to the right of the controller by completing the following steps 1 Ensure the AC power source is connected to the chassis before ins...

Page 9: ...el to the chassis using the front panel mounting screws Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis which can improve the signal quality and electromagnetic performance 11 Complete steps 5 through 10 for the PXI controller and PXI bus extension module 12 Cover all empty slots using either filler pan...

Page 10: ...XX EXHAUST PWR LINK 4 3 2 1 PXIe 8394 MXI Express PS TEMP FANS PXIe 8881 Embedded Controller USER1 USER2 DRIVE PWR OK FAULT TRIG RESET 10 100 1000 GPIB 10 100 1000 ACT LINK ACT LINK 0 1 1 2 1 8 6 5 7 3 4 2 7 1 Ettus USRP X410 2 PXIe Chassis 3 PXIe 8881 or other PXI Controller 4 PXIe 8394 or other PXI Bus Extension Module 5 Network Switch optional 6 PCIe MXI Express Cable 7 CAT 5E Ethernet Cable 8 ...

Page 11: ...a wall outlet Press the power button on the front of your device 3 Power on the chassis and network switch Installing the Software You must be an Administrator to install NI software on your computer 1 Install your ADE LabVIEW 2 Download the driver software installer from ni com downloads NI Package Manager downloads with the driver software to handle the installation Refer to the NI Package Manag...

Page 12: ...the combination of numbers and letters following serial as your unique serial number The serial number is also printed on a label on the bottom of your device Use the IP address following addr to identify your device in step 7 3 Use an SSH connection to access your device s management console a To open an SSH connection use your unique serial number to run the command ssh root ni x4xx serial Runni...

Page 13: ...o update the SSH security fingerprint of your device run the command ssh keygen R ni x4xx serial c To reconnect to the management console run the command ssh root ni x4xx serial d Type yes and press Enter if you are asked whether you want to continue connecting e To verify that you are using the updated file system run the command cat etc mender artifact_info The resulting output contains the vers...

Page 14: ...Chassis tree item MAX lists all modules installed in the chassis Your default names may vary Note If you do not see your module listed press F5 to refresh the list of installed modules If the module is still not listed power off the system ensure the module is correctly installed and restart 4 Record the identifier MAX assigns to the hardware Use this identifier to reference the Ettus USRP X410 Ve...

Page 15: ...ples Note You can access additional examples from the Code Sharing Community at ni com usrp Note The NI Example Finder does not include NI USRP examples Troubleshooting If an issue persists after you complete a troubleshooting procedure search our KnowledgeBase for additional information our technical support engineers create as they answer common user questions and resolve unexpected issues Why C...

Page 16: ...wing additional items Host PC Network switch CAT 5E Ethernet Cable optional One of the following QSFP28 to QSFP28 Ethernet cable and 100 Gb Ethernet network card QSFP28 to 4xSFP28 Ethernet breakout cable and 10 Gb Ethernet network card 2 Set all items on a flat surface near power outlets and a modem or router 3 Follow the instructions included with your network switch to connect it to a modem or r...

Page 17: ...4 100 G Ethernet Network Card 5 10 G Ethernet Network Card 6 QSFP28 to QSFP28 Ethernet Cable optional 7 CAT 5E Ethernet Cable optional 8 CAT 5E Ethernet Cable optional 9 QSFP28 to 4xSFP28 Ethernet Breakout Cable optional 10 Power Supply Table 7 Ettus USRP X410 Connections UHD Connector Type Connection 1 Connection 2 Label in Figure QSFP28 to QSFP28 Ethernet Cable Ettus USRP X410 QSFP28 0 Port 100 ...

Page 18: ...he power supply to the Ettus USRP X410 2 Plug the power supply into a wall outlet Press the power button on the front of your device 3 Power on the host PC and network switch Installing the Software To program your device with UHD install UHD on your host computer Navigate to the installation guide that applies to your operating system Linux ni com r linuxuhdinstall OS X ni com r osxuhdinstall Win...

Page 19: ... support to find support resources including documentation downloads and troubleshooting and application development self help such as tutorials and examples Visit ni com services to learn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ensures that you receive imp...

Page 20: ...ULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS...

Reviews: