3. Basic Operation
PROGRAMMABLE AC POWER SOURCE
52
--------
Notes
----------------------------------------------------------------------------------------------------------------
The AC voltage setting (ACV) is common between SIN and CLP, but ARB is independent of
these. When you switch the waveform selection among SIN, CLP, and ARB, the AC voltage
setting is also switched. The DC output voltage setting (DCV) is same regardless of the
waveform setting.
The waveform can be changed in the output on state, but the AC output voltage setting (ACV)
is also switched as described above if you switch the waveform selection between SIN, CLP,
and ARB. Set ACVs for SIN, CLP, and ARB in the output off state before you change the
waveform in the output on state.
---------------------------------------------------------------------------------------------------------------------------------
Operation procedure
1.
Select the [Wave] item.
2.
In the displayed selection box, select the desired waveform (SIN, CLP, ARB).
3.
If you select CLP or ARB, the [Select] icon (
) is displayed next to it. When you hover the
cursor over the [Select] icon, the clip ratio or crest factor is displayed for the clipped sine wave,
or the arbitrary waveform data name for the arbitrary waveform. When you press the ENTER