Acidic water 
outlet 

How To Install

pH test kit

Diverter

Hose

Color chart

Manual

Tap water

Inlet

Installation Method - At the sink with a diverter

1.  ATTACH DIVERTER TO YOUR TAP - Remove the aerator from tap (pliers may be required), and attach 
    diverter valve in its place.  There are adapters supplied in case the diverter does not fit your tap.  
    If you have leaks at the diverter, use plumber's Teflon tape. (Image No. 3) 
    (We are now including Teflon tape in ionizers. Please use this.).

1

2

3

Use a Teflon tape

Inlet hose
(PE hose)

Inlet Fitting(1/4”)

2. ATTACH THE WHITE TAP WATER INLET HOSE  -  Attach one end of the white hose to the gray port 
    on the bottom of the ionizer labeled "TAP WATER INLET" .  
    To attach the white hose, simply push it firmly into the 
    opening on grey port. 
    (If you need to remove it, press on the end of the fitting 
    while pulling out).

3. ATTACH THE GRAY ACIDIC WATER OUTLET HOSE  

    -  to the white plastic port labelled ACIDIC WATER 

    OUTLET on the bottom of the ionizer. First, slide 

    a squeeze clamp over the end of the hose. 

    Then attach the gray hose, by simply pushing it 

    firmly over the white plastic port. Soaking it in hot 

    water for 30 seconds will make attaching it very easy. 

    Squeeze the clamp and position it over the white port. 

    Ensure the opposite end runs into the sink.

5. POSITION YOUR IONIZER  -  Ensure it is on a hard and level surface. 

    A wall mount can be done - there are keyhole slots on the back for this.

 

6. ATTACH THE WHITE HOSE TO THE DIVERTER  -  Remove the small compression nut on 

    the back of the diverter (opposite of the lever). 

    Slide the nut over the opposite end of the white hose 

    you attached to the TAP WATER INLET port with the 

    threads positioned so it will screw it back onto the 

    diverter. Push the hose firmly onto the nipple, then 

    screw the compression nut back on. 

    Ensure the nut is screwed firmly in place, but do 

    not over tighten.

 7. CONNECT THE POWER CORD to an appropriate GFI outlet.

 8. INSTALL FLEXIBLE STAINLESS STEEL SPOUT  

    -  Screw this into the threaded port on the top of the ionizer. Do not over tighten.  

Summary of Contents for EN-7P

Page 1: ...er Warning Incorrect installation and or operation could void your valuable warranty Please protect your investment READ THIS MANUAL CAREFULLY NEXUS TECH CO LTD 362 Gwangmyeong Siboem Industrial Compl...

Page 2: ...ontact your dealer Attempting to do so will void your valuable warranty Do not use your ionizer at voltages other than specified AC 110V FOR USA Use a GFI outlet Do not plug in your ionizer where it w...

Page 3: ...Do not expose the pH measuring reagent to extreme heat flames or fire It is combustible Do not drink the pH reagent liquid put it in the eyes or apply to the body If the liquid is ingested induce vom...

Page 4: ...pH FAST FLOW lower pH Key hole Slots For Wall Mounting To save counter space you can mount your ionizer on the wall Note use suitable fasteners Fuse Holder Your ionizer comes equipped with a fuse to...

Page 5: ...r Low Water Pressure Indicator When lit this indicates insufficient operating pressure A beep sound is activated Your ionizer should not be operated when low pressure LED due to potential overheating...

Page 6: ...astic port labelled ACIDIC WATER OUTLET on the bottom of the ionizer First slide a squeeze clamp over the end of the hose Then attach the gray hose by simply pushing it firmly over the white plastic p...

Page 7: ...ve optimum results 3 TO SELECT ALKALINE WATER A Start Water Flow through your ionizer Remember The New ionizer cleans every times use But when the ionizer is operated within 1 minute have no cleaning...

Page 8: ...ng the ionizer is in standby or asleep How to Reset the Filter Life When the digital filter life indicator reaches full bar it is time to replace your filter Please replace the new filter and reset th...

Page 9: ...ween settings level 1 to 3 After setting the unit if the buttons are not pushed for another 5 seconds or if the water is run through the unit the last setting chosen is remembered Depress the ALKALINE...

Page 10: ...dvanced filtration system You can use it both as drinking water and to take medications with Some uses for the different levels of Acidic Water Alkaline water levels Note pH levels will always vary wi...

Page 11: ...s of the new filter Seat the large opening on the bottom of the filter cartridge onto the base Push the filter down and into the housing compartment ensuring the opening at the top of the filter is se...

Page 12: ...Carbon GAC The workhorse of the filtration media GAC is especially effective at removing chlorine its odor and taste agricultural chemicals phenol trihalomethane and other chemical contaminants Silver...

Page 13: ...pressure in your household plumbing The input hose is bent kinked or otherwise restricted Replace your filter Clean Pre filter Ensure water supply valves are fully open The water pressure in house ma...

Page 14: ...e center along with this warranty card for repair free of charge 2 Warranty term 24 months from a purchasing date 3 Exception to warranty Expiration of warranty terms Defect caused by a natural disast...

Reviews: