nextys OR20 Instruction Manual Download Page 4

OR20

Instruction Manual

OR20 V4.0

www.nextys.com

Page 4/5

Fig.4

Mounting / Dismounting Instructions

For DIN rail fastening according to IEC 60715 TH35-7.5(-15)

Mounting as shown in figure, with input terminals on lower side, with suitable cooling and maintaining a proper distance between adjacent devices as specified in the I.S.

manual of each family.

Mounting:

1

2

1.

Tilt the unit slightly backwards.

2.

Fit the unit over the top edge of the rail.

3.

Slide it downward until it hits the stop.

4.

Press against the bottom for locking.

3

4

Dismounting:

1.

Pull down the slide clamp lever

2.

Tilt the unit upward

3.

Unhook the unit from the rail

1 & 2

3

Fig.5

Recommended connecting cable

Recommended Tightening torque

0.5-0.6Nm

4.42-5.30 lbf in

Solid: 2.5mm² / 12AWG

Stranded:1.5mm² / 12AWG

L: 6.0-7.5mm / 0.24-0.30in

4

OR20_1680-21539-0007-E-1117

Summary of Contents for OR20

Page 1: ...5Vdc on a single model 20A Max Extremely low loss up to 99 efficiency Pluggable connectors Hot pluggable Up to 70 C operating temperature with no derating INDEX Page Installation Requirements 2 Declaration of Conformity 2 User Instructions 3 Connections 3 Dimensions 3 Distances 3 Mounting 4 Dismounting 4 Set up 5 Environment 5 Accessory Device 5 1 OR20_1680 21539 0007 E 1117 ...

Page 2: ...ischarge minimum 1 minute RISCHIO USTIONI ESPLOSIONE INCENDIO SCOSSA LESIONI GRAVI Non effettuare mai operazioni sulle parti sotto tensione Pericolo di lesioni letali Il contenitore può scottare lasciar quindi raffreddare il dispositivo prima di toccarlo Non far entrare liquidi o oggetti estranei nel dispositivo Per evitare scintille non collegare o scollegare l apparecchiatura prima di avere tolt...

Page 3: ...e is suitable for SELV and PELV circuitry if you use a source that having Uout higher 60Vdc is not a SELV device Check Uout before connecting the power supply to the load 5 Operating at the OR20 is possible connect 2 DC Power supplies in order to obtain a redundancy connection system see Fig 7 the 2 Power supplies must have setted the same Output voltage rating in order to ensure the corrected red...

Page 4: ...ified in the I S manual of each family Mounting 1 2 1 Tilt the unit slightly backwards 2 Fit the unit over the top edge of the rail 3 Slide it downward until it hits the stop 4 Press against the bottom for locking 3 4 Dismounting 1 Pull down the slide clamp lever 2 Tilt the unit upward 3 Unhook the unit from the rail 1 2 3 Fig 5 Recommended connecting cable Recommended Tightening torque 0 5 0 6Nm ...

Page 5: ...n condensing No Derating Note Data may change without prior notice in order to improve the product Please refer to the latest version of the Instruction Manual for each product by visiting www nextys com See also the products below that can be used in conjunction with OR20 units This device can be used in conjunction with every each our power supply that is able to provide an regulated Uout includ...

Page 6: ... 87 65 osman coban pewatron com Pressure Sensors Load Cells Philipp Kistler Phone 41 44 877 35 03 philipp kistler pewatron com Power supplies Sebastiano Leggio Phone 41 44 877 35 06 sebastiano leggio pewatron com Accelerometers Sensor elements Christoph Kleye Phone 49 89 374 288 87 61 christoph kleye pewatron com Harald Thomas Phone 49 89 374 288 87 23 harald thomas pewatron com Sales Other Countr...

Reviews: