Features

Your LCD Digital talking Multimeter is a portable, compact multimeter that is ideal for field, shop, 
and home applications.This Multimeter can display up to 4, 000 units. It measures AC voltage up 
to 750 V, DC voltage up to 1000 V, and resistance up to 40 M.

Rubber Case

 — Protects the meter.

Low Battery Indicator

 — So you can quickly see when you need to replace the battery.

Diode Check Function

 — Lets you safely check semiconductors for open, shorted, or normal 

junctions.

Full Auto Polarity Operation

 — Protects your meter and gives valid measurements even when 

you connect the leads in reverse polarity.

Latest IC and Display Technology

 — Ensures reliability, accuracy, stability, and ease of 

operation.

cUL Listed

 — Passes the stringent safety tests required by Canadian Underwriters Laboratories.

Note

: Your meter requires three  AA  batteries (not included) which you must install before using.

Important :

•  This meter is not designed for commercial, industrial, or outdoor use.
•  Completely read this manual before you use the meter.
•  If you are not familiar with multimeters and testing procedures, we suggest you read Using  

 

  Your Meter before using the meter.

Warnings :

•  Use extreme caution in use of this device. Improper use of this device can result in injury or    
  death. Follow all safeguards suggested in this user’s manual. In addition to normal safety  

 

  precautions in dealing with electrical circuits. Do not use this device if you are unfamiliar with
  electrical circuits and testing procedures. Not for commercial or industrial use.
•  If this equipment is used in a manner not specified by the manufacturer, the protection provided  
  by the equipment may be impaired.
•  To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.

A Word About Safety

We have taken every precaution in designing this meter to ensure that it is as safe as we can 
make it. But safe operation depends on you, the operator. We recommend that you follow these 
simple safety rules.

•  Never apply voltages to the meter that exceed the limits given in the specifications. Never  
  apply more than 500V DC or 500V RMS AC between the test leads and ground.
•  Use extreme caution when working with voltages above 100V. Always disconnect power from  
  the circuit you are measuring before you connect test leads to high-voltage points.
•  Never connect to a source of voltage when you select the diode check resistance  

 

  measurement function.
•   Always discharge any capacitors of the circuit under test before you attach test leads.
•  Always turn off power and disconnect the test leads from the circuit you are testing before you  
  replace the meter’s battery.
•  Never operate the meter unless its battery compartment cover is fully closed with the screw  
  fully tightened.
•  This equipment is rated for installation category III.
•  Because many AC/DC sets have a potentially hot chassis, be sure the top of your workbench  
  and the floor underneath it are made of non-conductive materials.
•  This meter is fully calibrated and tested. Under normal use, no further adjustment should be  
  necessary. 

Page 2

Digital Multimeter With Voice Readout

Summary of Contents for 2218202

Page 1: ...Please Read before using this equipment Digital Multimeter With Voice Readout 2218202 User s Manual ...

Page 2: ...h electrical circuits and testing procedures Not for commercial or industrial use If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired To reduce the risk of fire or shock hazard do not expose this product to rain or moisture A Word About Safety We have taken every precaution in designing this meter to ensure that it is as sa...

Page 3: ...ACV OHM DIODE CONTINUE CAP HZ DC AC mA Keys Hold key A short press will fix the display on the current value and hold it A second short press returns multimeter to normal mode The key is operative in all ranges Function key To select the function for the meter press the function key This key is operative in DC V AC V OHM DIODE BEEP and DC AC mA functions Rel key Relative measurement This key is ope...

Page 4: ...er try to measure a DC voltage above 1000 volts or an AC voltage above 750 volts RMS Over Voltage Protection 1000V DC 750V AC Operating Temperature 32 to 109 F 0 to 43 C Storage Temperature 4 to 140 F 20 to 60 C Relative Humidity 80 maximum Power Source 3 AA batteries Power Consumption 112 5 mW Typical Dimensions HWD 6 14 x 3 15 x 1 4 156 X 80 X 35 mm DC Volts Range Max Reading Resolution Accuracy...

Page 5: ...unts 5 120 uF 5 119 uF 1 nF 1 0 FS 10 Counts 512 0 nF 511 9 nF 100 pF 1 0 FS 10 Counts 51 20 nF 51 19 nF 10 pF 1 0 FS 10 Counts Frequency Note Normal Sensitivity 50 mV rms 10 MHz sensitivity 1 0 V rms Range Max Reading Accuracy 10 00 MHz 10 00 MHz 1 0 2 Counts 5 000 MHz 5 000 MHz 1 0 2 Counts 500 0 KHz 500 0 KHz 1 0 2 Counts 50 00 KHz 50 00 KHz 1 0 2 Counts 5 000 KHz 5 000 KHz 1 0 2 Counts 500 0 H...

Page 6: ... meter s case by pulling the tabs on the case in opposite directions Then unwind the test leads from inside the cover Caution The test leads are permanently attached to the meter Do not try to remove them Rotate the selector to the function you want to use Then connect the test leads to the circuit you want to measure See the unit of measure on the front of the meter to distinguish the range For e...

Page 7: ...he voltage developed across an unknown resistance Warning Be sure the circuit under testing has all power removed and any associated capacitors are fully discharged before you make a resistance measurement 1 Set the selector to OHM DIODE CONTINUE Caution Your meter has a circuit to protect the resistance range from over voltage However to prevent accidentally exceeding the protection circuit s rat...

Page 8: ...er to announce the test result press the switch on the red test lead for less than 1 5 seconds If you want the meter to be alluminated press the switch on the red test lead for more than 1 5 seconds and the meter will be lit for 30 seconds Frequency Measurement Position the selector switch on the Hz function Automatic range selection Read the measured value Hold if necessary by pressing the HOLD k...

Page 9: ... included with your Product or other accessories or external electrical systems resulting from the use of your Product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Defacing the serial number or using your Product for commercial or institutional purposes voids this warranty Are There Other Warra...

Reviews: