Page 4 of 10
1.
Access the engineering mode display screen
by pressing the Arrow “Up” and “Down” button
together and hold for 3~4 seconds.
If the voltage needs to be changed, Please follow these steps to adjust the voltage setting.
2.
In engineering mode (
voltage appears in the top,
middle of screen
), change voltage by pressing
the ‘P’ button. Please wait until you see that the
voltage has changed. Continue to press the “P”
button until your country specific voltage rating
appears.
3.
To save the voltage, turn off the LC-3D Print box
using the power switch on right side of the print
box.
4.
Once saved, the newly set voltage should
appear on the Welcome screen when the unit
is turned back on. This particular unit has been
changed to 220V.
Type of unit:
Model name:
Rated Voltage:
Power Consump-
tion:
Fuse:
Dimension:
Weight:
Light Polymerisation unit
(Post-curing oven)
LC-3DPrint Box
AC110-240V 50/60Hz
Max. 264W
AC250V T5.0A
W410 x D440 X H380
22Kg
Specifications