076
www.ruggedaq.com
DATALOGGER
NI400
NI400
077
www.ruggedaq.com
DATALOGGER
NI400
NI400
APN configuration
On the NI400 web server you can find a page where you have to edit an APN command.
This command is necessary to configure the 3G modem with the correct parameters
according to the selected SIM (these parameters depend on your ISP)
On the NI400 web server:
select the
Advanced
page from the left menu;
select the
Connection
page;
In the
Connection
page you have to:
write the APN of your Internet Service Provider (ISP) in the
APN
field (e.g.web.omnitel.it)
NOTE: if, in place of APN, there is the field AT command initialization
it is necessary to insert the following command: +CGDCONT=1,”IP”,”APN” (e.g.
+CGDCONT=1,”IP”,”web.omnitel.it”)
write the telephone number in “Telephone Number” field to establish a GPRS connec-
tion. Usually the number is
*99***1#
(connection using the default CID 1 overrode with the
AT+CGDCONT command).
write the
Username
and
Password
according to your ISP parameter
Press
Save Changes
to confirm the modifications
Reboot NI400 to make the changes effective
INTERNET OF THINGS
Overview
In this chapter IoT functionality
(optional)
offered by NI400 Datalogger are described, even
if it does not cover all configuration aspects that Exosite portal offers. For an accurate
description of all this aspects, please refer to the documentation page on Exosite portal:
https://support.exosite.com/hc/en-us/sections/200072708-Portals-Web-Interface-
The first paragraph of this guide is about following steps:
1. Add a device on Exosite portal
2. Configure the datalogger
3. Add data sources
4. Create Dashboard and add desired widgets
ADD A DEVICE ON EXOSITE PORTAL
Login to the Exosite portal at https://zionos.exosite.com/login
Figure 84
Figure 83
7
6