IMPORTANT SAFETY INSTRUCTIONS 

SAVE  THESE  INSTRUCTIONS  –  This  manual  contains  important 
instructions  for  NEXT  UPS  Systems  MANTIS  II  Tower  models 

500VA, 

750VA,  1000VA,  1500VA  that  should  be  followed  during  installation  and 
maintenance of the UPS and batteries. 

This product is specially designed for PCs and it is not recommended for
use in any medical equipment, life-supporting system and other specific
important equipment.

Do not plug household appliances such as hair dryers, microwave ovens
or vacuum cleaners to UPS.

Do not attach a power strip or surge suppressor to the UPS.

Do not plug the UPS into its own output.

Connection  to  any  other  type  of  receptable  other  than  two-pole,
three-wire  grounded  receptacle  may  result  in  shock  hazard  as  well  as
violate local electrical codes.

To  reduce  risk  of  overheating  the  UPS,  do  not  cover  the  UPS´  cooling
vents.

This unit intended for installation in a controlled environment (temperature
controlled, indoor area free of conductive contaminants). Avoid installing
the  UPS  in  locations  where  there  is  standing  or  running  water  or
excessive humidity and do not use it in any of the following environments:

o

Any area with combustible gas, corrosive substance or heavy dust.

o

Any area with extraordinarily high or low temperature (above 40˚C or
below 0˚C) and humidity of more than 90%.

o

Any area exposed to direct sunshine or near any heating apparatus.

o

Any area with serious vibrations.

o

Outdoor.

The utility power outlet shall be near the equipment and easily accessible.
In  the  event  of  an  emergency,  press  OFF  button  and  disconnect  the
power cord from the AC power supply to properly disable the UPS.

Summary of Contents for MANTIS II Tower 1000VA

Page 1: ...www nextups eu NEXT UPS Systems MANTIS II Tower 500 750 1000 1500 Installation and user manual English...

Page 2: ...S 1 1 Introduction 4 2 Description of Features 4 3 Package Contents 4 4 Product Overview 5 5 Installation and Initial Startup 7 6 Functions Operation 10 7 Software Installation on your PC 11 8 Mainten...

Page 3: ...may result in shock hazard as well as violate local electrical codes To reduce risk of overheating the UPS do not cover the UPS cooling vents This unit intended for installation in a controlled envir...

Page 4: ...m the device please cut off the power supply quickly and contact the distributor The UPS contains one two large capacity batteries So the shell shall not be opened otherwise such dangers as electric s...

Page 5: ...lso with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole...

Page 6: ...quipment to operate longer and more reliability 2 Description of Features Easy to use and install utilized microprocessor control to maximize the reliability and efficiency Equipped with built in boos...

Page 7: ...ear Panel MANTIS II 500T 750T MANTIS II 1000T 1500T AC input RJ11 RJ45 LAN Modem phone line protection USB port IEC outlet AC input RJ11 RJ45 LAN Modem phone line protection USB port IEC outlet Fan ON...

Page 8: ...ere is no activity for 3 minutes 1 In low sensitivity mode Lo UPS will tolerate more fluctuations in power and will go on battery power less often If the connected load is sensitive to power disturban...

Page 9: ...nductive contaminants Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature exceeds 0 40 C and the humidity is over 0 90 RH II Co...

Page 10: ...Phone line for Surge Protection Connect for example a single modem or phone line into surge protected IN outlet on the back panel of the UPS unit Connect from OUT outlet to the computer with another p...

Page 11: ...on the UPS unit by pressing the On Off button Turn off the UPS unit by pressing again the On Off button NEVER connect a laser printer or scanner to the UPS unit because in rush current generated by mo...

Page 12: ...e UPS it will automatically shut down after 5 minutes for energy saving while running on battery mode Disable by default The UPS will restart while AC recovery The green power function can be enable o...

Page 13: ...m the system administrator In addition to automatic file saving and system shut down functions it can also send warning messages via SMS e mail etc Use the bundled CD and follow the on screen instruct...

Page 14: ...s remove watches rings and other metal objects and only use insulated tools III Battery module replacement Battery tray removal on tower models This operation can be performed when the UPS is switched...

Page 15: ...ensure safety and high performance use only batteries supplied by NEXT UPS Systems Take care to firmly press together the two parts of the connector during remounting C Remove the metal protection cov...

Page 16: ...UPS Verify that the load matches the UPS capability specified in the specs 2 Power cord is loose Reconnect the power cord properly When power failure back up time is shorten 1 Overload of the UPS 1 R...

Page 17: ...midity 0 90 RH 0 to 40 C non condensing Noise Level Less than 40dB Less than 45dB Software Monitoring Software NEXTVIsion included downloadable CAPACITY 500VA 350W 1000VA 700W 1500VA 900W BATTERY Type...

Reviews: