NexPump Ai2800 User Manual Download Page 1

Users Manual

NexPump, Inc.
Phone: 630-365-4NEX (4639)
Fax: 630-365-6919
Email: [email protected]
Web Address: www.nexpump.com

Manual 3.01.0002
NexPump is a Registered Trademark of NexPump, Inc. 
Copyright © 2003-2010 NexPump, Inc., All Rights Reserved
Patent Pending

Summary of Contents for Ai2800

Page 1: ...hone 630 365 4NEX 4639 Fax 630 365 6919 Email support nexpump com Web Address www nexpump com Manual 3 01 0002 NexPump is a Registered Trademark of NexPump Inc Copyright 2003 2010 NexPump Inc All Righ...

Page 2: ...instructions for the NexPump Follow these important safety precautions Failure to follow safety precautions can result in personal injury or damage to the NexPump CAUTION To reduce the risk of injury...

Page 3: ...ause an explosion Remove personal metal items such as rings bracelets neck laces and or watches when working with a battery A battery can produce a short circuit current high enough to weld a ring or...

Page 4: ...e correct direction when installing the check valve Note If you are installing a single pump version install using Diagram A as a reference The second pump would be your installed electric pump PARTS...

Page 5: ...the mount ing bracket at the top Verify the sensor is not tilted in any way Step 2 SECURE WIRES Secure the pump and sensor wires to discharge pipes with nylon wire ties IMPORTANT Make sure the wire t...

Page 6: ...etup See Mode Selection NexPump Operation The NexPump will schedule an auto matic self test approximately two minutes after power up If there are any errors they will be displayed on the LCD display a...

Page 7: ...ode position on display o NexPump WILL display and sound an alarm if pump s are activated Indicated by A in the corresponding pump location Manual Mode Used to manually turn on both pumps o Switch in...

Page 8: ...tery Reset 8 Charging cycle will begin 9 If REP_ code sounds again soon after this procedure replace the Battery BATTERY MAINTENANCE Check Fluid levels if applicable in Battery at least once every 6 m...

Page 9: ...n and battery state before going to battery power will affect the calculated time throughout the power loss An alarm will also sound from the loss of electric power which may silenced See Silencing th...

Page 10: ...he pump is drawing to little current Troubleshooting H Clear alarm and run self test if pump again shows failure with H then pump is faulty Troubleshooting L Clear alarm and run self test if pump show...

Page 11: ...e last location of the display release the function button The display will show Alarm Cleared and return to normal PUMP REPLACEMENT Displayed as R or r Pump has reached average life span Pump may sti...

Page 12: ...electrical power cord The NexPump will remember what state the charge system was in and re enable the charging state to the condition is was when the unit was turned off After re con necting the batt...

Page 13: ...CING THE ALARM Repeat the above section on Silencing the alarm Instead of a S displaying a U will display DISABLING THE ALARM The alarm can be disabled if needed When disabled the alarm will not sound...

Page 14: ...s error is detected You may Disable the Alarm to stop the alarm sounding until the error is corrected Auto Notification Module Installed Notification will occur on a VRef Malfunctions Note VRef availa...

Page 15: ...lved Auto Notification Module Installed Notification will occur on an electric power loss If the alarm was silenced within 5 minutes of the alarm the notification system will be postponed If the alarm...

Page 16: ...ed again of the power failure Important Note Each time the alarm is cleared or after a call has been completed a notification counter is reset and will not allow the notification process to begin for...

Page 17: ...otification occurring after a silence period during a pro longed power outage Simply switch the mode to primary This will no longer sound the alarm or Notify on pump activa tion Remember to switch the...

Page 18: ...he Primary Mode for the duration of the event or if your main electric pump has failed 2 Sensor Alarms a High Water Alerts should NOT be cleared however the NexPump should be allowed to operate under...

Page 19: ...d Manual Test 1 Press Function Button Until T appears 6 seconds 2 Release Function Button 3 Test is scheduled Get Serial Number 1 The NexPumps serial number is located on the rear unit or proceed to s...

Page 20: ...d Page 12 ALDIS Alarm is disabled Resets in 5 days F Charge Status Page 11 Off Charge is off battery is fully charged Fxx Indicates the Full charge mode Txx Indicates the Trickle charge mode Mxx Indic...

Page 21: ...prepaid properly packed and insured NexPump Inc bears trans portation cost of the repaired product back to the purchaser This warranty applied only to the original purchaser NO OTHER WARRANTIES ARE E...

Page 22: ...21 Diagram A NexPump Ai5600 Installed as only pump Operating in Primary Mode...

Page 23: ...22 Diagram B NexPump Ai5600 Installed with existing pump Operating in Primary or Backup Mode Recommended Configuration...

Page 24: ...23 Diagram C NexPump Ai2800 Installed with existing pump Operating in Backup Mode ONLY...