NexPump Ai Single User Manual Download Page 12

PUMP OPERATIONS:

Pump Identifiers: 
‘O’  

Pump is off

‘I’ 

  Pump is on

‘A’ 

or 

‘a’ 

Pump was activated – Backup mode only 

    Note: If identifier is blinking, alarm is silenced

‘F’ 

or 

‘f’

 Pump Problem 

‘P’

 or 

‘p’ 

Possible Plumbing Clog Alert

‘V’ 

or 

‘v’ 

Possible Vapor Lock 

‘X' 

or 

'x’

 Suspected Clog Alert

‘Y'

 or 

'y’ 

Suspected Vapor Lock 

‘R’ 

or 

‘r’ 

Pump is over hour lifespan

‘Q’

 Pump Driver Problem

If Notification is Installed:

Notification will occur on all Pump Alerts after 
approximately five (5) Minutes, with the exception of  

‘A’ 

or 

‘a’

' (Pump Activation) which will occur after 

approximately thirty (30) Minutes.

Clear Pump Alerts:

To Clear any Pump Alert, use Function 

'C'

Testing:

Pumps are tested on 12 Hour Self-Tests or Manual Tests. 
Exceptions: Pump Problem

Menu Options for  Pump Operations:

Function 'K' Pump Operations: 

NONE

Function 'I' Pump Operations:

Info Item to check Pump Hours and Type:

(Pump 1 and Pump 2 (Dual Pump Version Only) Hours, 
with corresponding Type. 'H' = High Capacity, 'U' = Ultra 
Capacity)

Pump Troubleshooting:

Pump Codes:

Important: The Ai Turbo has a mixed Pump Type. 
Pump 1 should be the Pump with the RED wire loom.

Important:  Use NexPump OEM equipment ONLY.

 ‘

F’ or ‘f’

 - Pump Failure, followed by a corresponding ‘H’ 

or ‘L’ to indicate the failure type. Replace Pump

‘P’ or ‘p’ 

- Plumbing Clog. This alert indicates a possible 

clog in the plumbing discharge. Verify the discharge is 
clear of obstructions. In the winter it may indicate a frozen 
discharge pipe. 

‘V’ or ‘v’ 

- Vapor Lock Condition. This  alert indicates 

there may be air trapped in the discharge plumbing. It may 
also indicate Sensor 1 is stuck in the up position. If a check 
valve is used, check for a proper vent hole in the pump 
discharge pipe or check if the vent hole is clogged. 

‘R’ or ‘r’ 

- Pump has reached it’s operational life-span. 

The pump may still be operational, however the pump 
should be replaced as soon as possible. Contact NexPump 
for a replacement pump.

‘X’ or ‘x’ 

- ‘Clog Suspect Mode’.  Check information 

above for 

‘P’ or ‘p’ 

- Plumbing Clog.

‘Y’ or ‘y’ 

- ‘Vapor Lock Suspect Mode’. Check 

information above for 

‘V’ or ‘v’ 

- Vapor Lock Condition

‘Q’ 

- Pump Electronic Circuitry Problem. Call Support.

‘A’ or ‘a’ 

- Pump Activated (Backup Mode Only). In the 

Backup Mode you want to know if any of the NexPump 
Pumps needed to operate. This may indicate a failure of 
the Primary Pump or the Primary Pump could not operate 
due to an AC Power Outage or the Nexpump Pumps were 
needed for additional capacity. You will most likely be able 
to determine this if an event has or has NOT moved 
through your area. You can silence this alert by performing 
a Function 

'S'

. If this identifier is blinking the alarm is in 

the silence mode. You can also move the Mode Switch to 
the upper position to put the NexPump in the Primary 
Mode so the NexPump will not alarm for Pump Activation.

Pump Replacement:

‘R’ 

or 

‘r’

. Pump has reached it's life span. Pump may still 

be operational, however should be replaced at this time. 
 

12

Summary of Contents for Ai Single

Page 1: ...Phone 630 365 4NEX 4639 Fax 630 365 6919 Email support nexpump com Web Address www nexpump com Users Manual 4 00 0002 NexPump is a Registered Trademark of NexPump Inc Copyright 2003 2013 NexPump Inc...

Page 2: ...1 Surge Protector Supplied With Phone Line Notification Qty 1 Owners Manual Purchased Separately Required to operate 1 Deep Cycle Marine Battery See Appendix for more information You will also need t...

Page 3: ...h the NexPump powered up Risk of electric shock may result WARNING RISK OF EXPLOSIVE GASES WORKING IN THE VICINITY OFA LEAD ACID BATTERY CAN BE DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORM...

Page 4: ...NexPump System Unit connects to the NEGATIVE post of the battery The RED wire from the NexPump System Unit connects to the POSITIVE post of the battery The REVERSE POLARITY LED will illuminate if the...

Page 5: ...sor 1 is the main sensor and will turn on the pump s when the water rises above the sensor The Gray Sensor should be used for Sensor 1 Sensor 2 does not operate exactly like Sensor 1 however functions...

Page 6: ...the bottom of the connector and pull out the connector To disconnect a sensor connector slightly depress the security latch on the right side of the connector and pull out the connector Step 5 Connec...

Page 7: ...in down position The letter B will be blinking in the mode position on display o NexPump WILL display and sound an alarm if pump s are activated Indicated by A in the corresponding pump location Manua...

Page 8: ...Silence alarm Re Enables Alarm that was already Silenced T Run Manual Test K Runs Configuration Menu I Runs Stats Information Menu D Disable Alarm This will totally disable the alarm in the NexPump Un...

Page 9: ...if needed When disabled the alarm will not sound for any reason The alarm will be disabled for five 5 days and automatically enabled after that time You can Enable the Alarm before the five 5 Day per...

Page 10: ...s have a lifespan and should be replaced when the NexPump reports this time frame has expired This should also be reset when replacing batteries Defaults for battery type selected WET 1300 Days 3 5 Ye...

Page 11: ...ineral content may be used NEVER ADD MORE ACID Fill the battery cell so water is just below the fill cap Clean Battery Posts as needed with a 50 50 solution of water and baking soda or a wire brush Do...

Page 12: ...obstructions In the winter it may indicate a frozen discharge pipe V or v Vapor Lock Condition This alert indicates there may be air trapped in the discharge plumbing It may also indicate Sensor 1 is...

Page 13: ...s NONE Charger System Operation Charge Rate Ai Extreme Ai Dual 20 Amps Ai Single 10 Amps The charging circuit is disabled anytime the battery or electric power is disconnected or if both pumps are ope...

Page 14: ...nd wires are attached to each connector If the sensors are connected correctly the sensor may be defective AC POWER Input Power Identifiers O AC Power is Off I AC Power is On Note If identifier is bli...

Page 15: ...ckup VRef if this alert is detected If Notification is Installed Notification will occur on a Primary VRef Alert after approximately five 5 Minutes Clear Primary VRef Alerts Primary VRef Alerts will c...

Page 16: ...rState SRM 27B Group 27 DC 105 A H SRM 29 Group 29HM DC 120 A H Multiple Batteries Two Batteries may be connected in PARALLEL to increase time on battery power This configuration is highly recommended...

Page 17: ...Resets in 5 days F Charge Status Off Charge Off Fxx Full Mode Txx Trickle Mode Mxx Maintain Mode Dis Charge Disabled ttS Seconds Until Charge System Starts Fl_ Charge System Failed _ indicates the al...

Page 18: ...rial number is located on the rear unit or proceed to step 2 2 Press Function Button Until K appears 9 seconds 3 Release Function Button 4 Display shows SN Retrieve Firmware Revision 1 Press Function...

Page 19: ...e or Ultra Capacity pumps that have exceeded 1200 0 hours of operating time and does not cover equipment which had been tampered with in any way or to damage caused by accident negligence alteration m...

Page 20: ...20 Diagram A Ai Turbo or Ai Dual Installed as only pump Operating in Primary Mode...

Page 21: ...21 Diagram B Ai Rage Ai Turbo or Ai Dual Installed with existing pump Operating in Primary or Backup Mode Recommended Configuration...

Page 22: ...22 Diagram C Ai Single or Ai Jet Installed with existing pump Operating in Backup Mode ONLY...

Reviews: