PUMP OPERATIONS:
Pump Identifiers:
‘O’
Pump is off
‘I’
Pump is on
‘A’
or
‘a’
Pump was activated – Backup mode only
Note: If identifier is blinking, alarm is silenced
‘F’
or
‘f’
Pump Problem
‘P’
or
‘p’
Possible Plumbing Clog Alert
‘V’
or
‘v’
Possible Vapor Lock
‘X'
or
'x’
Suspected Clog Alert
‘Y'
or
'y’
Suspected Vapor Lock
‘R’
or
‘r’
Pump is over hour lifespan
‘Q’
Pump Driver Problem
If Notification is Installed:
Notification will occur on all Pump Alerts after
approximately five (5) Minutes, with the exception of
‘A’
or
‘a’
' (Pump Activation) which will occur after
approximately thirty (30) Minutes.
Clear Pump Alerts:
To Clear any Pump Alert, use Function
'C'
Testing:
Pumps are tested on 12 Hour Self-Tests or Manual Tests.
Exceptions: Pump Problem
Menu Options for Pump Operations:
Function 'K' Pump Operations:
NONE
Function 'I' Pump Operations:
Info Item to check Pump Hours and Type:
(Pump 1 and Pump 2 (Dual Pump Version Only) Hours,
with corresponding Type. 'H' = High Capacity, 'U' = Ultra
Capacity)
Pump Troubleshooting:
Pump Codes:
Important: The Ai Turbo has a mixed Pump Type.
Pump 1 should be the Pump with the RED wire loom.
Important: Use NexPump OEM equipment ONLY.
‘
F’ or ‘f’
- Pump Failure, followed by a corresponding ‘H’
or ‘L’ to indicate the failure type. Replace Pump
‘P’ or ‘p’
- Plumbing Clog. This alert indicates a possible
clog in the plumbing discharge. Verify the discharge is
clear of obstructions. In the winter it may indicate a frozen
discharge pipe.
‘V’ or ‘v’
- Vapor Lock Condition. This alert indicates
there may be air trapped in the discharge plumbing. It may
also indicate Sensor 1 is stuck in the up position. If a check
valve is used, check for a proper vent hole in the pump
discharge pipe or check if the vent hole is clogged.
‘R’ or ‘r’
- Pump has reached it’s operational life-span.
The pump may still be operational, however the pump
should be replaced as soon as possible. Contact NexPump
for a replacement pump.
‘X’ or ‘x’
- ‘Clog Suspect Mode’. Check information
above for
‘P’ or ‘p’
- Plumbing Clog.
‘Y’ or ‘y’
- ‘Vapor Lock Suspect Mode’. Check
information above for
‘V’ or ‘v’
- Vapor Lock Condition
‘Q’
- Pump Electronic Circuitry Problem. Call Support.
‘A’ or ‘a’
- Pump Activated (Backup Mode Only). In the
Backup Mode you want to know if any of the NexPump
Pumps needed to operate. This may indicate a failure of
the Primary Pump or the Primary Pump could not operate
due to an AC Power Outage or the Nexpump Pumps were
needed for additional capacity. You will most likely be able
to determine this if an event has or has NOT moved
through your area. You can silence this alert by performing
a Function
'S'
. If this identifier is blinking the alarm is in
the silence mode. You can also move the Mode Switch to
the upper position to put the NexPump in the Primary
Mode so the NexPump will not alarm for Pump Activation.
Pump Replacement:
‘R’
or
‘r’
. Pump has reached it's life span. Pump may still
be operational, however should be replaced at this time.