background image

ARRAY

 

EQ

 

 

 

P15-I

 

Page 

11

 / 

16

 

PNT-P15FLGPS 

Flange dispersion adapter PS 

 

PNT-P15FLG9040 

Flange dispersion adapter 90° - 40° 

 

 

 

ARRAY EQ

 

The ArrayEQ allows to adjust the system frequency response in its lower range  

(see curves below, with different ArrayEq values): 

 

 

 

 0

50

100

 00

500

1k

 k

5k

10k

 0k

 re uency     

 1 

 16

 14

 1 

 10

  

 6

 4

  

0

 

4

6

 

10

 6d 

  d 

 0d 

  d 

 6d 

 15 60 60  rray    d   ad usting

 0

50

100

 00

500

1k

 k

5k

10k

 0k

 re uency     

 1 

 16

 14

 1 

 10

  

 6

 4

  

0

 

4

6

 

10

 6d 

  d 

 0d 

  d 

 6d 

 15 60 60  rray    d   ad usting

Summary of Contents for P15-I

Page 1: ...DP5548 01 DI P15 I User manual ...

Page 2: ..._ 8 ACCESSORIES _________________________________________________________________________ 9 ARRAY EQ____________________________________________________________________________ 11 MAINTENANCE ________________________________________________________________________ 12 TECHNICAL SPECIFICATIONS ___________________________________________________________ 14 USER NOTES _________________________________...

Page 3: ...l accidentally If the system is used on a tripod please ensure the tripod s specifications are adapted and that its height does not exceed 1 40m 55 Do not move the tripod with the system in position Connection and Powering Precautions Unplug connected cables before moving the system Power off the system before connecting the system When switching on the installation the amplifier must be powered l...

Page 4: ... PLADAPT on P15 I Put the assembly on the distance rod monitor stand diameter of 35mm IMPORTANT Speaker stand must be rated for P15 weight Speaker stand must always be installed on a horizontal surface Stand height and footprint must be defined to prevent assembly from collapsing Ensure that audience is not allowed within a safety area which radius is equal or higher than assembly height Test stea...

Page 5: ...lification The P15 speakers must be used with a NEXO processor to handle EQ phase alignment crossover and excursion thermal protection for the system loudspeaker There are two NEXO processor series supporting the P15 speakers NXAMP 4 channels amplified processors and DTD processors stereo sub DTD processors ensure optimal performances when used with DTDAMP power amplifiers The following table show...

Page 6: ...Warning this setup is a low latency setup and therefore its phase is not compatible with other NEXO cabinets including subs Preset P15 MON PA 6060 with high pass at 57 85 or 120 Hz P15 MON PA 9040 with high pass at 57 85 or 120 Hz P15 MON PA PSguide with high pass at 57 85 or 120 Hz P15 MAIN PA 6060 with high pass at 57 85 or 120 Hz P15 MAIN PA 9040 with high pass at 57 85 or 120 Hz P15 MAIN PA PS...

Page 7: ...PRESET P15 I Page 7 16 P15 Sub Stage monitor applications with Subs OMNI or CARDIO modes Front of house applications with Subs OMNI or CARDIO modes ...

Page 8: ...on allow to deal with every request 1 Loosen the 2 screws Remove the grille 2 Remove the 4 HF Cap 3 Place the flange if necessary rotate it 4 Magnets keep the horn in place When replacing the grille ensure it is well positioned in the top blade before fasten the hooks with the screws CROSSOVER FREQUENCY 57 Hz Full range application 85 Hz Use as front fill on stage complementing a main system Use w...

Page 9: ...es provided by NEXO NEXO will decline responsibility over the entire P15 accessory range if any component is purchased from different supplier PROHIBITED P15 below P15 or P15 below L18 without dedicated accessory PNT BUMP LiftBar for PLUS serie use with P15 WMADAPT PNT HBRK15 Horizontal Cradle use with CLADAPT PLADAPT PNT PLADAPT Pole Adapter use with P15 HBRK15 VBRK15 PNT VBRK15 Vertical Cradle u...

Page 10: ...age 10 16 P15 I PNT WMADAPT With PNI WMxxx PNT BUMP PNI CLADAPT Ceiling Adapter use with HBRK8 VBRK8 PNI P15TOL18 PNI P15TO2L18 P15 Under 1xL18 P15 Under 2xL18 Omni or Cardio PNI WM380 Wallmount for P15 with WMADAPT ...

Page 11: ...ArrayEQ allows to adjust the system frequency response in its lower range see curves below with different ArrayEq values 0 50 100 00 500 1k k 5k 10k 0k re uency 1 16 14 1 10 6 4 0 4 6 10 6d d 0d d 6d 15 60 60 rray d ad usting 0 50 100 00 500 1k k 5k 10k 0k re uency 1 16 14 1 10 6 4 0 4 6 10 6d d 0d d 6d 15 60 60 rray d ad usting ...

Page 12: ...ews Remove the grille 2 Remove 8 screws Tightening torque 3 5 Nm Thread Locker Loctite 242 3 Remove the stickers 4 Remove the 2 screws Tightening torque 2 5 Nm Thread Locker Loctite 222 5 Remove the horn 6 To access to the HF diaphragm remove 4 screws Tightening torque 2 Nm ...

Page 13: ...plete grille Instal White with fasteners 2 2 05RUBGRD01 Plastic Pad Black 2 05RUBGRD01 PW Plastic Pad White 3 1 05HPC15 P15 driver complete with screws 1 05HPC15R K Recone Kit 15 with screws 4 1 05NHP15R K HF diaphragm with screws 5 4 05CAPB01 HF cap black 4 05CAPB01 PW HF cap White NOTE Speakers and Grills can be sent back to NEXO for recycling 1 4 5 ...

Page 14: ...cy 57Hz 85 Hz 120 Hz Nominal Impedance Ω SPECIFICATIONS Model P8 I Components LF 1x15 Ω HF 1x 3 Ω Neodymium driver Material Baltic birch Poplar plywood Finish Black or white structural paint Front finish Black or white acoustic fabric fitted front steel front grille Fittings Threated inserts on the back and on both sides for connection of mounting accessories Connector Cable gland supplied with a ...

Page 15: ...USER NOTES P15 I Page 15 16 USER NOTES ...

Page 16: ...Page 16 16 P15 I NEXO S A arc d activité de la Dame Jeanne F 60128 PLAILLY Tel 33 3 44 99 00 70 Fax 33 3 44 99 00 30 E mail info nexo fr nexo sa com ...

Reviews: