Cabling
NEXO recommends the exclusive use of multi-conductor cables to connect the system: the cable kit is compatible with all the
cabinets, and there is no possible confusion between LF, MF and HF sections.
Cable choice consists mainly of selecting cables of the correct sectional dimension (size) in relation to the load resistance and
the cable length. Too small a cable section will increase both its serial resistance and its capacitance; this reduces the electrical
power delivered to the loudspeaker and can also induce response (damping factor) variations.
For a serial resistance less or equal to 4% of the load impedance (damping factor = 25), the recommended cable length is given
by:
L
max
= Z x S
S in mm
2
, Z in Ohm, L
max
in meters
The table below indicates these values, for 3 common sizes.
Load Impedance (
)
2
2.6
4
5.3
8
16
Cable section
Recommended Cable Length
1,5 mm² (AWG #15)
3m/10ft
3m/13ft
6m/20ft
8m/26ft
12m/39ft
24m/79ft
2,5 mm² (AWG #13)
5m/16ft
7m/23ft
10m/33ft
13m/44ft
20m/66ft
40m/131ft
4 mm² (AWG #11)
8m/26ft
10m/33ft
16m/52ft
21m/70ft
32m/105ft 64m/210ft
6 mm
2
(AWG #9)
12m/40ft
16m/52ft
24m/79ft
32m/104ft 48m/160ft 96m/315ft
Maximum allowed length is 4 times recommended length.
Example:
GEO M6 module has a 8
nominal impedance. When connecting 4 modules in parallel, total load impedance become 2
.
Recommended length for 4mm2 / (AWG#10) is 8 m / 26 ft, maximum allowed length is 32 m / 105 ft.
IMPORTANT
Long speaker cables induce capacitive effects
– up to hundreds of pF depending on the quality of the
cable - with a low-pass effect on high frequencies. If long speaker cables must be used, ensure that they
do not remain coiled while in use.
2.3
GEO M620 and GEO M6B recommended amplification
NEXO TD Controllers
Recommended amplification
DTD Cont DTDAMP4x1.3 (4x1.3 kW/4
)
2 x GEO M620 per channel
2 x GEO M6B per channel
NXAMP4x1mk2 Powered Controller 4 channels mode (4x1.3kW/2
)
3 x GEO M620 per channel
3 x GEO M6B per channel
NXAMP4x2mk2 Powered Controller 4 channels mode (4x2.5kW/2
)
4 x GEO M620 per channel
4 x GEO M6B per channel
2.4
GEO M6 setups on NEXO TD Controllers
Please consult nexo-sa.com for NEXO TD Controllers firmware information.
Summary of Contents for Geo M6 Series
Page 1: ...System Manual GEOM6 DP2537 06 CM GEO M6 GEO M620 GEOM6B Tangent Array Modules System manual ...
Page 11: ...CONNECTION DIAGRAMS System Manual GEOM6 Page 11 64 3 2 GEO M620 NXAMP4x1mk2 4 channels mode ...
Page 13: ...CONNECTION DIAGRAMS System Manual GEOM6 Page 13 64 3 4 GEO M620 LS18 mono bridged NXAMP4x1mk2 ...
Page 14: ...CONNECTION DIAGRAMS Page 14 64 System Manual GEOM6 3 5 GEO M620 NXAMP4x2mk2 4 channels mode ...
Page 42: ...TECHNICAL SPECIFICATIONS Page 42 64 System Manual GEOM6 Dimensions ...
Page 44: ...TECHNICAL SPECIFICATIONS Page 44 64 System Manual GEOM6 Dimensions ...
Page 46: ...TECHNICAL SPECIFICATIONS Page 46 64 System Manual GEOM6 Dimensions ...
Page 63: ...USER NOTES System Manual GEOM6 Page 63 64 10 USER NOTES ...