Nexmosphere X-EYE XY-510 Product Manual Download Page 7

X is a value between 

1-100

 and it's default value is 

10

. This 

level determines the threshold for the sensor to qualify the 

detected gender as confidence level "low" (L). Increasing 
X will result into the sensor having to be more confident 
on the detected Gender before qualifying the confidence 

level as "low" (L). Decreasing X will result into the sensor 

having to be less confident on the detected Gender before 
qualifying the confidence level as "low" (L). 

X is a value between 

1-100

 and it's default value is 

10

. This 

level determines the threshold for the sensor to qualify 

the age estimation as confidence level "low" (L). Increasing 
X will result into the sensor having to be more confident 
on the age estimation in order to qualify the confidence 

level as "low" (L). Decreasing X will result into the sensor 

having to be less confident on the age estimation before 
qualifying the confidence level as "low" (L). 

X is a value between 

1-100

 and it's default value is 

50

. This 

level determines the threshold for the sensor to qualify the 

detected gender as confidence level "high" (H). Increasing 
X will result into the sensor having to be more confident 
on the detected Gender before qualifying the confidence 

level as "high" (H). Decreasing X will result into the sensor 

having to be less confident on the detected Gender before 
qualifying the confidence level as "high" (H). 

X is a value between 

1-100

 and it's default value is 

50

. This 

level determines the threshold for the sensor to qualify the 

age estimation as confidence level "high" (H). Increasing 
X will result into the sensor having to be more confident 
on the age estimation in order to qualify the confidence 

level as  "high" (H). Decreasing X will result into the sensor 

having to be less confident on the age estimation before 
qualifying the confidence level as "high" (H). 

When disabling (1), the sensor will not send an API message 

when the detected Gender changes and the confidence 

level of the detected gender is "low" (L).

When disabling (1), the sensor will not send an API message 

when  the  age  estimation  changes  and  the  confidence 

level of the age estimation is "low" (L).

Default, the sensor does not send an API  message when 
the detected gaze direction changes. When enabling 
(1), the sensor will send an API message when the gaze 
direction changes.

The age range mapping are as follows:

© 2020 Nexmosphere. All rights reserved. v1.0 / 11-20  

All content contained herein is subject to change without prior notice

N ex m o s p h e re

Le   H av re   1 3 6
5 6 2 7   SW   E i n d h ove n   •   T h e   N e t h e r l a n d s

T

  + 3 1   4 0   2 4 0   7 0 7 0

E

  s u p p o r t @ n ex m o s p h e re.c o m

7

PRODUCT MANUAL | X-EYE GENDER SENSOR

Setting 12: Gender confidence level "Low"

Set gender confidence level low 

 

Setting 16: Age confidence level "Low"

Set age confidence level low 

 

Setting 13: Gender confidence level "High"

Set gender confidence level high   

Setting 17: Age confidence level "High"

Set age confidence level high 

 

Setting 14: Trigger at low confidence level Gender

Setting 18: Trigger at low confidence level Age estimate

Setting 19: Trigger at change of Gaze direction

Setting 15: Select Age Range mapping

X001S[12:

X

]

X001S[16:

X

]

X001S[13:

X

]

X001S[17:

X

]

X001S[14:1]

X001S[18:1]

X001S[18:1]

X001S[14:2]

X001S[18:2]

X001S[18:2]

X001S[15:1]

X001S[15:2]

X001S[15:3]

X001S[15:4]

1. Age range mapping 1 (default) 
2. Age range mapping 2   
3. Age range mapping 3
4. Age range mapping 4 

1. No trigger at low confidence 

2. Yes, trigger at low conf. (def)

1. No trigger at low confidence 

2. Yes, trigger at low conf. (def)

1. Yes, trigger at gaze change
2. No trigger at gaze change (def)

1 (def)

2

3

4

Age range 0

0-11

0-9

0-11

0-11

Age range 1

12-17

10-19

12-17

12-19

Age range 2

18-24

20-29

18-24

20-29

Age range 3

25-34

30-39

25-29

30-39

Age range 4

35-44

40-49

30-34

40-44

Age range 5

45-54

50-59

35-39

45-54

Age range 6

55-64

60-69

40-44

55-59

Age range 7

>=65

>=70

45-54

60-64

Age range 8

N/A

N/A

55-64

65-69

Age range 9

N/A

N/A

>=65

>=70

Summary of Contents for X-EYE XY-510

Page 1: ...der sensors feature the same functionality and will detect the gender and estimate the age of the person in front of the sensor The detection range and field of view varies between the two models Nexmosphere Le Havre 136 5627 SW Eindhoven The Netherlands T 31 40 240 7070 E suppor t nexmosphere com PRODUCT MANUAL X EYE GENDER SENSOR 2020 Nexmosphere All rights reserved v1 0 11 20 All content contai...

Page 2: ...ng The sensor only detects one person at a time and will always analyze the person closest to the sensor The confidence level thresholds very low low and high can be adjusted Please see section 5 Settings page 7 Whether or not the sensor should send an API command when the confidence level on the detected gender is low can be adjusted Please see section 5 Settings page 7 P Person detection 0 No Pe...

Page 3: ...n 5 Settings page 7 The sensor determines the gaze direction based on the position and angle of the person s jaw It does not take the eye direction into account When the gaze direction is unidentified this will be indicated with an U 2020 Nexmosphere All rights reserved v1 0 11 20 All content contained herein is subject to change without prior notice Nexmosphere Le Havre 136 5627 SW Eindhoven The ...

Page 4: ...lk interface before powering the Xperience controller Otherwise the X Eye Gender sensor will not be recognized by the Xperience controller and no sensor output will be provided 4 XN this side up X Eye DC Power supply XC this side up X Eye 4 2 Hardware integration guidelines Orientation placement sensor Install the sensor in the orientation depicted in the illustration on the right In all other ori...

Page 5: ...or t nexmosphere com PRODUCT MANUAL X EYE GENDER SENSOR 5 XY 510 XY 520 Field of view Angle 90 50 Min detection distance 15cm 35cm Max detection distance 120cm 250cm Field of view angle and detection range When installing the sensor take the field of view angle into account to make sure the sensor can detect the people which are standing in front of it Panel cut out The lens of the sensor needs to...

Page 6: ...rved v1 0 11 20 All content contained herein is subject to change without prior notice Nexmosphere Le Havre 136 5627 SW Eindhoven The Netherlands T 31 40 240 7070 E suppor t nexmosphere com 6 PRODUCT MANUAL X EYE GENDER SENSOR 5 Settings The X Eye Gender sensor has multiple settings which determine the behaviour and output of the sensor The settings can be adjusted by sending X talk setting comman...

Page 7: ...Whendisabling 1 thesensorwillnotsendanAPImessage when the detected Gender changes and the confidence level of the detected gender is low L Whendisabling 1 thesensorwillnotsendanAPImessage when the age estimation changes and the confidence level of the age estimation is low L Default the sensor does not send an API message when the detected gaze direction changes When enabling 1 the sensor will sen...

Page 8: ...er up is completed will be lit continuously Step 2 Test detection Stand in front of the sensor with you face directed towards the sensor s lens The status LED of the controller should blink For a full test we recommend to connect the setup to a mediaplayer or PC and test all API commands listed in this document see section 3 page 2 3 For more information on how to setup a test for your controller ...