3.2 - Age estimation

When a person is detected, the sensor analyzes real-time 

in what range the person's age is. There are 7 different age 

ranges of which the default mapping is as follows: 
 

Range 0 =  

age 00 - age 11

 

Range 1 =  

age 12 - age 17

 

Range 2 =  

age 18 - age 24

 

Range 3 =  

age 25 - age 34

 

Range 4 =  

age 35 - age 44

 

Range 5 =  

age 45 - age 54

 

Range 6 =  

age 55 - age 64

 

Range 7 =  

age 65 and older

Simultaneously,  it  also  indicates  the  confidence  level 
of  the  estimated  age  range.  On  the  right,  example  API 

trigger commands are provided. When applying these 
commands, please consider the following:

• 

There  are  4  different  age  range  mappings  available. 

Please see section 5 "Settings", page 7.

• 

When the age range is unidentified, the age range will 
be indicated as 0, followed by confidence level X. 

• 

The  confidence  level  thresholds  can  be  adjusted. 

Please see section 5 "Settings", page 7.

•  Whether or not the sensor should send an API 

command when the confidence level on the detected 

age is low can be adjusted. Please see section 5 
"Settings", page 7.

3.3 - Gaze indication

When a person is detected, the sensor analyzes real-time 
the direction of the person's gaze: Left, Center or Right. 

On the right, example API trigger commands are provided. 

When applying these commands, please consider the 
following:

•  Default, no API trigger is send when a new gaze 

direction is detected.

 This can be enabled. Please 

see section 5 "Settings", page 7.

•  The sensor determines the gaze direction based on 

the position and angle of the person's jaw. It does not 
take the eye direction into account.

• 

When  the  gaze  direction  is  unidentified,  this  will  be 

indicated with an U. 

© 2020 Nexmosphere. All rights reserved. v1.0 / 11-20  

All content contained herein is subject to change without prior notice

N ex m o s p h e re

Le   H av re   1 3 6
5 6 2 7   SW   E i n d h ove n   •   T h e   N e t h e r l a n d s

T

  + 3 1   4 0   2 4 0   7 0 7 0

E

  s u p p o r t @ n ex m o s p h e re.c o m

3

PRODUCT MANUAL | X-EYE GENDER SENSOR

Example commands

Example commands

Person detected (1), Male (M), Low confidence on gender (L)

, Age 

range 

2

, Low confidence on Age (

L

), 

Gaze unidentified

Person detected (1), Male (M), Low confidence on gender (L), Age range 
7, High confidence on Age (H)

, Gaze Left (

L

)

Person detected (1), Female (F), High confidence on gender (H)

, Age 

range 

6

, High confidence on Age (

H

), 

Gaze Center

Person detected (1), Female (H), High confidence on gender (H), Age 
range 5, Low confidence on Age (L)

, Gaze Center (

C

)

Person detected (1), Female (F), High confidence on gender (H)

, Age 

range 

4

, Low confidence on Age (

L

), 

Gaze Left

Person detected (1), Male (M), High confidence on gender (H), Age 
range 4, Low confidence on Age (L)

, Gaze Right (

R

)

Person detected (1), Female (F), Low confidence on gender (L), Age 
range unidentified (0X)

, Gaze Unidentified (

U

)

Person detected (1), Male (M), High confidence on gender (H)

, Age 

range Unidentified (

0X

)

, Gaze Unidentified (U)

Person detected (1), Gender unidentified (UX),

 Age range 

Unidentified (

0X

)

, Gaze Unidentified (U)

X001B[

1ML

2L

U

]

X001B[

1ML7H

L]

X001B[

1FH

6H

C

]

X001B[

1FH5L

C]

X001B[

1FH

4L

L

]

X001B[

1MH4L

R]

X001B[

1FL0X

U]

X001B[

1MH

0X

U

]

X001B[

1UX

0X

U

]

Summary of Contents for X-EYE XY-510

Page 1: ...der sensors feature the same functionality and will detect the gender and estimate the age of the person in front of the sensor The detection range and field of view varies between the two models Nexmosphere Le Havre 136 5627 SW Eindhoven The Netherlands T 31 40 240 7070 E suppor t nexmosphere com PRODUCT MANUAL X EYE GENDER SENSOR 2020 Nexmosphere All rights reserved v1 0 11 20 All content contai...

Page 2: ...ng The sensor only detects one person at a time and will always analyze the person closest to the sensor The confidence level thresholds very low low and high can be adjusted Please see section 5 Settings page 7 Whether or not the sensor should send an API command when the confidence level on the detected gender is low can be adjusted Please see section 5 Settings page 7 P Person detection 0 No Pe...

Page 3: ...n 5 Settings page 7 The sensor determines the gaze direction based on the position and angle of the person s jaw It does not take the eye direction into account When the gaze direction is unidentified this will be indicated with an U 2020 Nexmosphere All rights reserved v1 0 11 20 All content contained herein is subject to change without prior notice Nexmosphere Le Havre 136 5627 SW Eindhoven The ...

Page 4: ...lk interface before powering the Xperience controller Otherwise the X Eye Gender sensor will not be recognized by the Xperience controller and no sensor output will be provided 4 XN this side up X Eye DC Power supply XC this side up X Eye 4 2 Hardware integration guidelines Orientation placement sensor Install the sensor in the orientation depicted in the illustration on the right In all other ori...

Page 5: ...or t nexmosphere com PRODUCT MANUAL X EYE GENDER SENSOR 5 XY 510 XY 520 Field of view Angle 90 50 Min detection distance 15cm 35cm Max detection distance 120cm 250cm Field of view angle and detection range When installing the sensor take the field of view angle into account to make sure the sensor can detect the people which are standing in front of it Panel cut out The lens of the sensor needs to...

Page 6: ...rved v1 0 11 20 All content contained herein is subject to change without prior notice Nexmosphere Le Havre 136 5627 SW Eindhoven The Netherlands T 31 40 240 7070 E suppor t nexmosphere com 6 PRODUCT MANUAL X EYE GENDER SENSOR 5 Settings The X Eye Gender sensor has multiple settings which determine the behaviour and output of the sensor The settings can be adjusted by sending X talk setting comman...

Page 7: ...Whendisabling 1 thesensorwillnotsendanAPImessage when the detected Gender changes and the confidence level of the detected gender is low L Whendisabling 1 thesensorwillnotsendanAPImessage when the age estimation changes and the confidence level of the age estimation is low L Default the sensor does not send an API message when the detected gaze direction changes When enabling 1 the sensor will sen...

Page 8: ...er up is completed will be lit continuously Step 2 Test detection Stand in front of the sensor with you face directed towards the sensor s lens The status LED of the controller should blink For a full test we recommend to connect the setup to a mediaplayer or PC and test all API commands listed in this document see section 3 page 2 3 For more information on how to setup a test for your controller ...

Reviews: