4
FORM NO. L-20318-E-1112
1. Insert the customer supplied key into the motor shaft keyway
(See Figure 1).
2. Slide the FMCE onto the motor shaft and secure it to the
motor using customer supplied socket head cap screws
and lock washers (See Figure 1).
3. Align the Set Screw (Item 26) in the Drive Disc (Item 4) with
the hole in the FMCE Housing (See Figure 1).
4. Tighten the Set Screw (Item 26); then, install the Plug (Item
27) (See Figure 1).
FMCE 875, 1125, AND 1375 MOUNTED ON THE SHAFT END OF A MOTOR
1. Insert the customer supplied key into the motor shaft keyway
(See Figure 2).
2. Remove the Socket Head Cap Screws (Item 24) and the
Female Pilot (Item 13); then, secure the Female Pilot to the
motor face using customer supplied socket head cap screws
(See Figure 2).
3. Slide the FMCE Housing (Item 1) onto the motor shaft (See
Figure 2).
4. Apply a drop of Loctite
®
242 to the threads of the Socket
Head Cap Screws (Item 24) (See Figure 2).
5. Secure the FMCE Housing (Item 1) to the Female Pilot
(Item 13) using Socket Head Cap Screws (Item 24); then,
alternately and evenly tighten the Socket Head Cap Screws
to the recommended torque (See Figure 2 and Table 1).
6. Align the Set Screw (Item 26) in the Drive Disc (Item 4) with
the hole in the FMCE Housing (See Figure 2).
7. Tighten the Set Screw (Item 26); then, install the Plug (Item
27) (See Figure 2).
FIGURE 1
Customer supplied
socket head cap screws
and lock washers
Customer supplied key
Motor
FMCE
Housing
Set Screw
(Item 26)
Plug
(Item 27)
TABLE 1
INSTALLATION
FMCE 625 MOUNTED ON THE SHAFT END OF A MOTOR
CAUTION
Use caution not to bump or damage the
Sensors during assembly or disassembly.
NOTE
Align the Solenoid Valve, located on the
FMCE, to a down position to allow condensa-
tion to drain out of the air chamber
Customer supplied
socket head cap screws
Set Screw
(Item 26)
Plug
(Item 27)
Socket Head
Cap Screws
(Item 24)
Female Pilot
(Item 13)
FMCE
Housing
FIGURE 2
Motor
Customer
supplied key
RECOMMENDED TIGHTENING TORQUE
MODEL
TIGHTENING TORQUE
FMCE 875 (Item 24)
157 In. Lbs. [17.7 N•m]
FMCE 1125 (Item 24)
267 In. Lbs. [30.2 N•m]
FMCE 1375 (Item 24)
580 In. Lbs. [65.0 N•m]
CAUTION
Use caution not to bump or damage the
Sensors during assembly or disassembly.
NOTE
Align the Solenoid Valve, located on the
FMCE, to a down position to allow condensa-
tion to drain out of the air chamber