5
FORM NO L-20347-H-1112
AIR AND ELECTRICAL CONNECTIONS
NOTE: the clutch brake's integral valve manifold has
three 0.125-18 NPT holes; one is marked "INLET" and
the other two are exhaust ports.
1. Connect the air supply to the port marked "INLET."
FIGURE 4
36
40
WARNING
Prior to connecting any wires, be sure
that AC power is turned off, locked and
proper signage applied according to safety
regulations. Avoid splicing wires.
Table 3
2. Install the gasket included with the DIN Connector
(See Figure 4, Item 40) onto the Solenoid Valve
(Item 36).
3. Attach DIN Connector Cable to integral valve by
pressing DIN Connector onto valve power pins and
tightening DIN Connector fastener.
4. Connect DIN Connector Cable wires using the
following chart to the appropriate power supply
(Table 3).
INL
ET
Exhaust Port
Exhaust Port
Integral Valve Specifications
Voltage
Power
Resistance Current
115 VAC
2.5 W
5500 ohms .021 A
24 VDC
.6 W
1100 ohms .027 A
DIN
Connector
Cable Wire
Color
Valve Type
24 VDC
115 VAC
Valve Pin
Brown
+
Line
1
White
-
Neutral
2
Green
Ground
Ground
Ground
NOTE: 24 VDC and 115 VAC valves require different
power cables. Power cables for 24 VDC valve is a
straight-through type. Power cables for 115 VAC
valve has a full bridge rectifier and surge suppressor
built in.
CAUTION
24 VDC valve has a suppression diode
installed across its coil. Observe proper voltage
polarity or coil damage will result.