background image

Copyright © 2014 NEXCOM International Co., Ltd. All Rights Reserved.

7

Chapter 2: Description of the LED Indicators

VES30-4S and VES30-8S User Manual

Chapter 2: Description of the LED Indicators

Power and Low Voltage Protection LEDs

LED

LED Behavior

POWER

Light Off: Power Off.
Light On (Green): Power On.

LOW 

VOLTAGE

Light Off: Battery voltage is normal.
Light On (Red): The status of low voltage occurs.

POWER

LOW

VOLTAGE

PoE Status LEDs

LED

LED Behavior

1 to 4 

(VES30-4S)

Light Off: Power is not supplied to PD (Powered Device).
Light On (Yellow): Power is supplied to PD (Powered Device).

1 to 8

(VES30-8S)

Light Off: Power is not supplied to PD (Powered Device).
Light On (Yellow): Power is supplied to PD (Powered Device).

PoE

7

5

3

1

8

6

4

2

Summary of Contents for VES30-4S

Page 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published November 2014 www nexcom com Mobile Computing Solutions In Vehicle PoE Switch VES30 4S and VES30 8S User Manual ...

Page 2: ...n xi Chapter 1 Product Introduction Overview 1 Key Features 1 Physical Features 2 VES30 8S Front View 2 VES30 8S Bottom View 2 VES30 4S Front View 3 VES30 4S Bottom View 3 Mechanical Dimension 4 VES30 8S 4 VES30 4S 5 Hardware Specifications 6 Chapter 2 Description of the LED Indicators Power and Low Voltage Protection LEDs 7 PoE Status LEDs 7 LAN Port LEDs 8 Chapter 3 Description of the External C...

Page 3: ... has a CE marking For computer systems to remain CE compliant only CE compliant parts may be used Maintaining CE compliance also requires proper cable and cabling techniques Copyright This publication including all photographs illustrations and software is protected under international copyright laws with all rights reserved No part of this manual may be reproduced copied translated or transmitted...

Page 4: ... to be your trusted green partner and to protect our environment RoHS restricts the use of Lead Pb 0 1 or 1 000ppm Mercury Hg 0 1 or 1 000ppm Cadmium Cd 0 01 or 100ppm Hexavalent Chromium Cr6 0 1 or 1 000ppm Polybrominated biphenyls PBB 0 1 or 1 000ppm and Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and ma...

Page 5: ...ts located on the sides Firm support from the bottom is highly necessary in order to provide balance stability Installation Recommendations Ensure you have a stable clean working environment Dust and dirt can get into components and cause a malfunction Use containers to keep small components separated Adequate lighting and proper tools can prevent you from accidentally damaging the internal compon...

Page 6: ... anything on top of the power cord Use a power cord that has been approved for use with the product and that it matches the voltage and current marked on the product s electrical range label The voltage and current rating of the cord must be greater than the voltage and current rating marked on the product All cautions and warnings on the equipment should be noted If the equipment is not used for ...

Page 7: ...sales representative please have the following information ready before calling Product name and serial number Detailed information of the peripheral devices Detailed information of the installed software operating system version application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and han...

Page 8: ...13F No 920 Chung Cheng Rd ZhongHe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7796 Fax 886 2 8226 7792 Email sales nexcom com tw www nexcom com tw NEXCOM Intelligent Systems Taichung Office 16F No 250 Sec 2 Chongde Rd Beitun Dist Taichung City 406 R O C Tel 886 4 2249 1179 Fax 886 4 2249 1172 Email sales nexcom com tw www nexcom com tw Japan NEXCOM Japan 9F Tamachi Hara Bldg 4 11 5 ...

Page 9: ...m eu Italy NEXCOM ITALIA S r l Via Gaudenzio Ferrari 29 21047 Saronno VA Italia Tel 39 02 9628 0333 Fax 39 02 9625570 Email nexcomitalia nexcom eu www nexcomitalia it Chengdu Office 9F Shuxiangxie Xuefu Garden No 12 Section 1 South Yihuan Rd Chengdu 610061 China Tel 86 28 8523 0186 Fax 86 28 8523 0186 Email sales nexcom cn www nexcom cn Shanghai Office Room 603 604 Huiyinmingzun Plaza Bldg 1 No 60...

Page 10: ...e all the items listed in the following table Item Part Number Name Description Qty 1 5040420054X00 N VES30 8S Mount V Bracket VER A JAN YU 140x31x10mm SPCC NI Plating T 1 2mm 2 2 5040420053X00 N VES30 8S Mount H Bracket VER A JAN YU 140x24x23mm SPCC NI Plating T 1 2mm 2 3 50311F0110X00 H Flat Head Screw Long FEI F3x5ISO Nylok NIGP F3x5 NI Nylok 8 4 4NCPM00302X00 T Terminal Blocks 3P Phoenix Conta...

Page 11: ...for VES30 4S and VES30 8S VES30 8S P N 10VE0003001X0 8x RJ45 10 100 1000 PoE port 802 3af 1x RJ45 10 100 1000 Ethernet port 9 36VDC input ignition detection low voltage protection delay timer E13 mark VES30 4S P N 10VE0003000X0 4x RJ45 10 100 1000 PoE port 802 3af 1x RJ45 10 100 1000 Ethernet port 9 36VDC input ignition detection low voltage protection delay timer E13 mark ...

Page 12: ...IP camera without the need for additional power lines simplifying device integration for surveillance applications in transportation The mobile PoE switches also support wide operating temperatures of 30 C to 70 C wide voltage input range of 9VDC to 36VDC and provide smart power management with low battery voltage protection power on and power off delay timer and auto ignition power on off functio...

Page 13: ...roduct Introduction VES30 4S and VES30 8S User Manual Physical Features VES30 8S Front View Power LED Low Voltage LED DIP Switch Power On Off Delay Setting Low Input Voltage Protection Setting DC IN 9V 36V PoE 1 to 8 Ports LAN1 to LAN8 PoE Status LEDs LAN0 VES30 8S Bottom View ...

Page 14: ...apter 1 Product Introduction VES30 4S and VES30 8S User Manual Power LED Low Voltage LED DIP Switch Power On Off Delay Setting Low Input Voltage Protection Setting DC IN 9V 36V PoE 1 to 4 Ports LAN1 to LAN4 PoE Status LEDs LAN0 VES30 4S Bottom View VES30 4S Front View ...

Page 15: ...Copyright 2014 NEXCOM International Co Ltd All Rights Reserved 4 Chapter 1 Product Introduction VES30 4S and VES30 8S User Manual Mechanical Dimension VES30 8S 166 92 211 00 139 6 51 49 ...

Page 16: ...Copyright 2014 NEXCOM International Co Ltd All Rights Reserved 5 Chapter 1 Product Introduction VES30 4S and VES30 8S User Manual VES30 4S 166 92 211 00 139 6 51 49 ...

Page 17: ... ignition Ethernet 8x RJ45 10 100 1000 Mbps PoE port 802 3af compliance VES30 8S 4x RJ45 10 100 1000 Mbps PoE port 802 3af compliance VES30 4S 1x RJ45 10 100 1000 Mbps LED 1x power indicator 8x PoE indicator VES30 8S 4x PoE indicator VES30 4S 1x low voltage protection indicator Power Management Selectable boot up shut down voltage for low power protection by DIP switch Power on off delay time sett...

Page 18: ...ht Off Power Off Light On Green Power On LOW VOLTAGE Light Off Battery voltage is normal Light On Red The status of low voltage occurs POWER LOW VOLTAGE PoE Status LEDs LED LED Behavior 1 to 4 VES30 4S Light Off Power is not supplied to PD Powered Device Light On Yellow Power is supplied to PD Powered Device 1 to 8 VES30 8S Light Off Power is not supplied to PD Powered Device Light On Yellow Power...

Page 19: ...on of the LED Indicators VES30 4S and VES30 8S User Manual LAN Port LEDs LED LED Behavior LINK Light Off No link Light On Green 100Mbps or 1Gbps network link ACT Light Blinking Yellow Data is being transmitted or received Light Off No data is being transmitted or received 1 8 ACT LINK ...

Page 20: ...PoE VES30 4S LAN5 8 PoE VES30 8S Pin Definition Pin Definition 1 LAN_MDI_0P 2 LAN_MDI_0N 3 LAN_MDI_1P 4 LAN_MDI_2P 5 LAN_MDI_2N 6 LAN_MDI_1N 7 LAN_MDI_3P 8 LAN_MDI_3N 9 LAN_LINK 10 LAN_LED1 11 LAN_ACTLED 12 LAN_LED2 Pin Definition Pin Definition 1 LAN_MDI_0P 2 LAN_MDI_0N 3 LAN_MDI_1P 4 LAN_MDI_2P 5 LAN_MDI_2N 6 LAN_MDI_1N 7 LAN_MDI_3P 8 LAN_MDI_3N 9 LAN_LINK 10 LAN_LED1 11 LAN_ACTLED 12 LAN_LED2 1...

Page 21: ...S User Manual DC Input 9V 36V Pin Definition 1 GND_IN 2 V_IN 3 IGNITION 1 3 I Power On Off Delay Settings Power ON Delay Time Pin 2 Pin 1 Disabled 0 0 10 seconds 0 1 30 seconds 1 0 60 seconds 1 1 Power OFF Delay Time Pin 4 Pin 3 Disabled 0 0 1 minute 0 1 5 minutes 1 0 10 minutes 1 1 Default setting 1 O N 2 3 4 5 6 7 8 Pin 1 OFF Default Pin 8 ...

Page 22: ...inimum power on voltage Minimum operation voltage Pin 6 Pin 5 Disabled 9 36V Disabled 9 36V Disabled 9 36V Disabled 9 36V 0 0 11 5V 10 5V 23V 21V 0 1 12V 11V 24V 22V 1 0 12 5V 11V 25V 22V 1 1 If the vehicle battery voltage drops lower than the above minimum power on and minimum operation voltages for 6 minutes VES30 will be shut down If the vehicle battery voltage ranges between 6V 9V for 30 secon...

Page 23: ...Rights Reserved 12 Chapter 3 Description of the External Connector Pinouts VES30 4S and VES30 8S User Manual Input Voltage Settings Voltage Range Pin 8 Pin 7 9 36VDC 0 0 12VDC 0 1 24VDC 1 0 Default setting 1 O N 2 3 4 5 6 7 8 Pin 1 OFF Default Pin 8 ...

Reviews: