Copyright © 2011 NEXCOM International Co., Ltd. All Rights Reserved.
70
NISE 2100, NISE 2100A, NISE 2110, NISE 2110A User Manual
Appendix A: Power Consumption
Power Consumption Measurement
Purpose
The purpose of the power consumption test is to verify the power dissipa-
tion of the system and the load of the power supply.
Test Equipment
PROVA CM-07 AC/DC CLAMP METER
Device Under Test
DUT: Sys #1
Test Procedure
1. Power up the DUT and then boot Windows XP.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Run the Intel Kpower program.
5. Run the LAN Packet Counter and Receive program.
Test Data
Sys #1
+12V
Full-Loading Mode
2.18A
Total
26.16W
Standby Mode
0.9A
Total
10.8W